REMOTE METER OPERATION INSTRUCTION
The button switches from left to right (K1 to K4) are: Set, Left, Right and ON/OFF/ESC
1. The meter display in sequential order:
Solar panel voltage and charging current, then Battery voltage and charging current minus load current, then
Load voltage and Load current, then Battery capacity in AH and battery temp., then battery capacity percentage
and temp. compensation, then battery capacity in AH and battery type, then charge accumulation in AH and
charge accumulation in WH then discharge accumulation in AH and discharge accumulation in WH. Use K2, K3, or
Left, right button for repeating any data set. The following picture shows what the data looks like.
is the "setting" icon. It shows when setting status, and disappears when reading status.
2. Data setting operation:
Reading status, press K1/SET to "setting" status, press K2, K3 to modify data. K1 : return to reading status and
save data. K4 : return to reading status without saving data. Battery voltage and current can't be set.
Operation shows as following picture.
The following data can be adjusted: battery capacity AH, battery temperature compensation,
battery type. On read status, press K1/SET for setting data.
3.
Data setting instruction
Battery capacity: Battery capacity can be set from 10AH to 900AH, the default value is 200AH. The value should
be near or equal to the real capacity. While display shows battery capacity and temp., press K1 into "setting"
mode, modify the data through K2, K3. Battery capacity will go up/down 10AH, press K1 for saving data and
return to the reading status, or press K4 for return without saving.