CHARACTERISTICS
LCD
all system parameters as digital values
system status as symbols
Intelligent software control
PWM charging mode
Set three different battery types
Battery Ah setting
Over-load, short circuit, reverse polarity protection,electronic fuse
Temperature compensation setting
Modify parameters using four buttons
INSTRUCTION MANUAL
----------For SHS controller, with remote meter
----------Controller: EPIPC-COM series
----------Meter: MT-2

Advertisement

loading

Summary of Contents for WESTECH EPIPC-COM Series

  • Page 1 INSTRUCTION MANUAL ----------For SHS controller, with remote meter ----------Controller: EPIPC-COM series ----------Meter: MT-2 CHARACTERISTICS  all system parameters as digital values  system status as symbols  Intelligent software control  PWM charging mode  Set three different battery types ...
  • Page 2: Technical Information

    TECHNICAL INFORMATION Type EPIPC-COM(10A) EPIPC-COM(20A) System voltage 12V/24V AUTO WORK Rated charging current Rated load current Overload 1.25 X rated load current for 60 seconds or 1.5 X for 5 secs short circuit protection ≥3 times of rated load current Self consumption ≤6 mA Charging circuit voltage drop...
  • Page 3: Installation

    INSTALLATION Connect the individual components according to the symbols, they are solar panel, battery and load. Follow the order indicated i.e. connect the battery first. Install the controller near the battery. The installation environment should be dry, preferably indoors. If for outdoor use, provide a waterproof and dustproof enclosure.
  • Page 4: Mechanical Drawing

    MECHANICAL DRAWING CONTAINS Wall mounting board, can be mounted in or on the wall. With 1.5 meter cable REMOTE METER DISPLAY Battery icon Load icon Solar icon Error indicator Unit indicator Setting icon Data indicator  The two LED indicators above the LCD show that battery is charging, and a red indicates error conditions. The LCD has three different brightness levels.
  • Page 5 REMOTE METER OPERATION INSTRUCTION The button switches from left to right (K1 to K4) are: Set, Left, Right and ON/OFF/ESC 1. The meter display in sequential order: Solar panel voltage and charging current, then Battery voltage and charging current minus load current, then Load voltage and Load current, then Battery capacity in AH and battery temp., then battery capacity percentage and temp.
  • Page 6 Battery temp. compensation: Temp. compensation data modify ranges from 0 to 10mV/Cell/ C, while the data is 0, there is no temp. compensation function. While displaying battery capacity percentage and temp. compensation, press K1 to go to “setting” mode, modify the data through K2, K3. The temp. compensation will be up/down 1 mV/Cell/℃.
  • Page 7 Charging accumulation is the product of battery voltage, charging current and time, displayed in Watt hours. Discharging accumulation WH: Discharging accumulation is the product of battery voltage, discharge current and time, displayed in Watt hours. Westech-Solar Energy GmbH E-mail:service@westech-solar.com Website:www.westech-solar.com...