Keysight W4630 Series Installation Manual
Keysight W4630 Series Installation Manual

Keysight W4630 Series Installation Manual

Ddr4 bga interposer
Hide thumbs Also See for W4630 Series:

Advertisement

Quick Links

Keysight W4630 Series
DDR4 BGA Interposer
Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W4630 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Keysight W4630 Series

  • Page 1 Keysight W4630 Series DDR4 BGA Interposer Installation Guide...
  • Page 2 Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 3: In This Guide

    In This Guide This document provides installation information for the following Keysight products: • W4633A DDR4 x4/x8 BGA Command and Data Interposer • E5849A High Data Rate Single-ended ZIF Cable (for use with the W4633A interposer) Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 4 Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 5: Table Of Contents

    Connecting the E5849A Probe Cables to a Logic Analyzer Logic Analyzer Channel Mapping Signals not probed by the Logic Analyzer 3 Setting Up the Logic Analyzer for W4630 Series Probes Before You Start Load ing a Configuration File To save a configuration file...
  • Page 6 Guidelines for Shelf Life and Solder-ability of W4633A Interposers Cleaning of W4633A Interposer Gold Fingers Safety Information for the E5849A Cable Adapters To clean the instrument Safety Symbols Regulatory Notices WEEE Compliance China RoHS Index Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 7: Introduction

    Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide Introduction W4630 Series DDR4 BGA Interposer - Introduction / 8 Hardware and Software Requirements / 12 Mechanical Considerations / 13 DDR3 Probes / 17 This chapter introduces the hardware components that are needed for a W4630-series interposer setup.
  • Page 8: W4630 Series Ddr4 Bga Interposer - Introduction

    DRAM would normally be soldered. The interposer is designed to be soldered to the PCB footprint for the DRAM on top of either the DDR4 riser included with the W4630 series BGA interposer or an optional Grypper socket (not included with the interposer). The DRAM being probed is then soldered to the top side of the interposer.
  • Page 9: Riser And Optional Grypper Socket

    DDR4 78 ball DRAM. To know how to solder the riser to the interposer and PC board, refer to the topic “Soldering the W4633A Interposer and Riser" on page 21. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 10: E5849A Single-Ended Zif Probe Cable

    E5849A Single-ended ZIF probe cable To know how to make connections between the W4633A interposer and E5849A probe cables, refer to the topic “Connecting the W4633A Interposer to E5849A Probe Cables" on page 23. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 11: U4201A 90-Pin Logic Analyzer Cables

    U4201A 90-pin logic analyzer cable To know how to make connections between the U4201A cable and E5849A probe cable, refer to the topic “Connecting the E5849A Probe Cables to a Logic Analyzer" on page 27. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 12: Hardware And Software Requirements

    Access to Number of Number of ZIF Number of Number of Logic Analyzer Mod ules Interposers Probes Cables Command, One W4633A Two E5849A Four U4201A One U4154A module Address, Control and Data Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 13: Mechanical Considerations

    Introduction Mechanical Considerations W4633A Interposer Dimensions The following figure shows the dimensions of a W4633A DDR4 DRAM BGA interposer. Figure 5 Dimensions of a W4633A interposer Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 14: Keep-Out Volume

    You must install the W4633A interposer on a riser (shipped with the interposer) or a grypper NOTE socket to provide clearance to surrounding DRAM and RCs on the bottom side of the interposer. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 15 Introduction Figure 7 KOV of a W4633A interposer The following figure shows the KOV of an E5849A probe cable when connected to a W4633A interposer. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 16 Introduction Figure 8 KOV of a W4633A interposer with an E5849A cable (SIDE VIEW) Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 17: Ddr3 Probes

    • W3636A DDR3 x16 non-stacked DRAM96 ball BGA probe. • E5845A adapter cable for W3631A and W3636A probes. • E5847A adapter cable for W3633A probe. • W3635B DDR3 oscilloscope probe adapter. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 18 Introduction Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 19: Setting Up The W4630-Series Interposers

    Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide Setting up the W4630-Series Interposers W4633A Interposer Setup - Overview / 20 Soldering the W4633A Interposer and Riser / 21 Connecting the W4633A Interposer to E5849A Probe Cables / 23 Connecting the E5849A Probe Cables to a Logic Analyzer / 27...
  • Page 20: W4633A Interposer Setup - Overview

    Use a grounded wrist strap and other ESD control measures as appropriate. Do not open the vacuum sealed packs of the W4633A interposer until you are ready to install NOTE the interposer. Discard these packs once the package is opened. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 21: Soldering The W4633A Interposer And Riser

    • When possible use a PCA rework vendor, to attach the riser, interposer and memory components, such as: Circuit Technologies Center. More useful information can be found at: http://www.circuitrework.com. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 22: Interposer Fabrication Notes

    When the W4633A interposer is soldered to a riser, flatness must be maintained on the order of 3.5 mils or less across the BGA footprint to maximize successful soldering to the interposer. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 23: Connecting The W4633A Interposer To E5849A Probe Cables

    The right wing of Cable 2 connects to P3-Address/Command wing of the interposer while the left wing of Cable 2 has not been used and left unconnected. Figure 10 W4633A Interposer and E5849A Cable Connections Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 24 To attach an E5849A ZIF connector to a flex wing of the W4633A interposer, perform the following three steps. Angle the flex wing of the interposer into an E5849A ZIF connector. GND towards door closure. Align the E5849A ZIF connector tabs with interposer’s wing notches. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 25: W4633A Interposer Wings Pinout

    DQS#_2 DQS#_1 DQS_2 DQS_1 RST# DQ2_2 DQ2_1 PULLDN DQ6_2 DQ6_1 DQ7_2 ALERT# DQ7_1 E5849A Cable 1 E5849A Cable 1 E5849A Cable 2 Left Wing Connector Right Wing Connector Right Wing Connector Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 26 J2 - ADDRESS/COMMAND J3 - ADDRESS/COMMAND DQ3_2 DQ3_1 DQ1_2 ACT# DQ1_1 DM#_2 DM#_1 DQS_2 DQS_1 E5849A Cable 1 E5849A Cable 1 E5849A Cable 2 Left Wing Connector Right Wing Connector Right Wing Connector Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 27: Connecting The E5849A Probe Cables To A Logic Analyzer

    When you connect the E5849A probe cables to a U4154A Logic Analyzer as per the diagram in Figure 12, the logic analyzer channels are mapped to signals as per the table displayed below. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 28: Signals Not Probed By The Logic Analyzer

    U4154A Logic Analyzer Pods Signals not probed by the Logic Analyzer The following signals are omitted from the Logic Analyzer connections for the W4633A interposer. Interposer Signal Name W4633A VREFCA, TEN, ZQ Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 29: Setting Up The Logic Analyzer For W4630 Series Probes

    Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide Setting Up the Logic Analyzer for W4630 Series Probes Before You Start / 30 Loading a Configuration File / 31...
  • Page 30: Before You Start

    Setting Up the Logic Analyzer for W4630 Series Probes Before You Start Ensure that all the software components listed in the topic “Hardware and Software Requirements" on page 12 are installed on the host computer and the required software licenses are also obtained and installed.
  • Page 31: Loading A Configuration File

    Because of these dependencies, there is no single logic analyzer configuration file setup for the W4630-series interposers. A set of DDR4 x4 and x8 configuration files is provided with the Keysight B4621B Decoder software. To obtain this set of configuration files, you must install the B4621B software (licensing of this software is not required for obtaining these configurations).
  • Page 32 Setting Up the Logic Analyzer for W4630 Series Probes Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 33: Characteristics, Regulatory, Safety And Storage Information

    Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide Characteristics, Regulatory, Safety and Storage Information Operating Characteristics / 34 Storage, Inspection, Baking, and Cleaning Guidelines / 35 Safety Information for the E5849A Cable Adapters / 36 Regulatory Notices / 37...
  • Page 34: Operating Characteristics

    Up to 50% noncondensing. Avoid sudden, extreme temperature changes which could cause condensation on the circuit board. For indoor use only. Characteristics Description To interposer Memory bus signals from target system From interposer High-density connectors for Keysight U4154A AXIe-based logic analyzer modules Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 35: Storage, Inspection, Baking, And Cleaning Guidelines

    If the test passes, proceed with the assembly (reflow) of interposer. • If delamination occurs, the interposer cannot be used. Cleaning of W4633A Interposer Gold Fingers • Use Isopropyl alcohol to clean W4633A interposer contacts. • Never use abrasive cleaning materials. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 36: Safety Information For The E5849A Cable Adapters

    "Caution" or "Warning" risk of danger marked on product. See "Safety Notices" on page 2 and refer to this manual for a description of the specific danger. Hazardous voltage symbol. Earth terminal symbol: Used to indicate a circuit common connected to grounded chassis. Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 37: Regulatory Notices

    Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as a "Monitoring and Control Instrumentation" product. Do not d ispose in domestic household waste. To return unwanted products, contact your local Keysight office, or see "www.keysight.com"...
  • Page 38 Characteristics, Regulatory, Safety and Storage Information Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 39 U4201A, 11, interposer, inputs to, interposer, outputs from, introduction, W4633A, W4633A interposer setup, WEEE compliance, keep-out volume, Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...
  • Page 40 Index Keysight W4630 Series DDR4 DRAM BGA Interposers Installation Guide...

Table of Contents