Download Print this page

Eagle 1403 Installation Manual page 2

Remote control relay module

Advertisement

MODEL
1241
TERMINAL 1
TERMINAL 2
P7
4.0 CONFIGURATION.
4.1 MODEL 1403 DIP SWITCHES.
The dip switches on the Model 1403 may be configured to best suit the application. The adjustable
parameters include momentary or latching; momentary duration; activation digits used.
S
1 - 4: control whether the relay is momentary or latching.
WITCHES
SW1 -
OFF = RELAY 1 LATCHING
ON = RELAY 1 MOMENTARY
SW2 -
OFF = RELAY 2 LATCHING
ON = RELAY 2 MOMENTARY
SW3 -
OFF = RELAY 3 LATCHING
ON = RELAY 3 MOMENTARY
SW4 -
OFF = RELAY 4 LATCHING
ON = RELAY 4 MOMENTARY
S
5: Controls relay bank; high or low.
WITCH
SW5 -
OFF = RELAYS 1-2-3-4 (low bank)
ON = RELAYS 5-6-7-8 (high bank)
Switch 5 controls which four digits control the module. If switch 5 is OFF then commands 1
through 4 control the module. If switch 5 is ON then commands 5 through 8 control the module. If two
modules are used, it is desirable to have one module on each setting thus giving eight (8) independent
'zones'. If both modules are set to the same range, then two relays will be activated with each command.
S
6: Controls momentary duration, if selected.
WITCH
SW6 -
OFF = MOMENTARY ACTIVATION DURATION = 350 mSEC
ON = MOMENTARY ACTIVATION DURATION = 1.5 SEC
1403
MODEL
+12
GND
RY1
THERMOSTAT
NC
24VAC
POWER
RY1
COM
WARM UP
RY1
THERMOSTAT
NO
( SET TO 72 )
RY2
NC
NORMAL
THERMOSTAT
RY2
( SET TO 50 )
COM
RY2
TYPICAL APPLICATION
NO
RAISES TEMPERATURE OF
A BUILDING WITH A
SIMPLE PHONE CALL.
EAGLE
SECURITY PRODUCTS
SW1
ON
OFF
1 2 3
4 5
6
2
RY4
NO
RY4
COM
RY4
NC
RY3
NO
RY3
COM
RY3
NC
ADDITIONAL
MODEL 1403
P1
P2

Advertisement

loading