Panasonic CU-4Z80TBE Service Manual page 880

Hide thumbs Also See for CU-4Z80TBE:
Table of Contents

Advertisement

19.2.2
Two Indoor Unit Operation
Cooling Characteristic
[Condition] Room temperature: 27°C (DBT), 19°C (WBT)
Operation condition: High fan speed
Piping Length: 5m
Voltage: 230V, 50Hz
A) Indoor unit capacity: Cooling (2.0kW + 2.5kW), CS-Z20TKEW + CS-Z25TKEW, service mode frequency = 49 Hz
15.400
14.920
14.440
13.960
13.480
13.000
-10
-6
-2
2
11.400
10.160
8.920
7.680
6.440
5.200
-10
-6
-2
2
0.940
0.916
0.892
0.868
0.844
0.820
-10
-6
-2
2
5.600
5.240
4.880
4.520
4.160
3.800
-10
-6
-2
2
6
10
14
18
22
Outdoor Air Temperature (°C)
6
10
14
18
22
Outdoor Air Temperature (°C)
6
10
14
18
22
Outdoor Air Temperature (°C)
6
10
14
18
22
Outdoor Air Temperature (°C)
880
Z20TKEW
Z25TKEW
26
30
34
38
42
26
30
34
38
42
26
30
34
38
42
26
30
34
38
42
46
46
46
46