A single outdoor unit enables air conditioning of up to five separate rooms for CU-5Z90TBE.
o
CONNECTABLE INDOOR UNIT
ROOM
CS-MZ16TKE
1.6kW
CS-MTZ16TKE
CS-Z20TKEW
CS-XZ20TKEW
2.0kW
CS-TZ20TKEW
CS-TE20TKEW
CS-Z25TKEW
CS-XZ25TKEW
CS-TZ25TKEW
2.5kW
CS-TE25TKEW
CS-E9PD3EA
CS-E9PB4EA
CS-Z35TKEW
CS-XZ35TKEW
CS-TZ35TKEW
3.5kW
CS-TE35TKEW
CS-E12QD3EAW
CS-E12PB4EA
CS-Z42TKEW
4.2kW
CS-TZ42TKEW
CS-TE42TKEW
CS-Z50TKEW
CS-XZ50TKEW
CS-TZ50TKEW
5.0kW
CS-TE50TKEW
CS-E18RD3EAW
CS-E18RB4EAW
CS-TZ60TKEW
6.0kW
CS-TE60TKEW
CS-E21RB4EAW
CS-Z71TKEW
7.0kW
CS-TZ71TKEW
Capacity range of connectable indoor units
1-room maximum pipe length (m)
Allowable elevation (m)
Total allowable pipe length (m)
Total pipe length for maximum
chargeless length (m)
Additional gas amount over
chargeless length (g/m)
Remarks for CU-5Z90TBE
1.
At least two indoor unit must be connected.
2.
The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of indoor
unit. (as shown in the table above)
Example: The indoor units' combination below is possible to CU-5Z90TBE.
(Total nominal capacity of indoor units is between 4.5kW to 18.3kW)
1) Two CS-Z25TKEW only. (Total nominal cooling capacity is 5.0kW)
2) Three CS-Z42TKEW only. (Total nominal cooling capacity is 12.6kW)
A
B
15
OUTDOOR UNIT
CU-5Z90TBE
C
D
-
-
-
-
4.5kW ~ 18.3kW
25
15
80
45
20
E
-
-
-
-
Note: "
" : Available

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-5z90tbe

Table of Contents