Advertisement

Quick Links

X2 marine 15 - B2 HBSC
English
MAEN229, 2021-11

Advertisement

Table of Contents
loading

Summary of Contents for Beijer Electronics X2 marine 15

  • Page 1 X2 marine 15 - B2 HBSC English MAEN229, 2021-11...
  • Page 2 The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any information without updating this publication. Beijer Electronics AB, including all its group companies, assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    Digital Outputs ..........20 X2 marine 15 - B2 HB SC Outline ......21 7 Additional Installation Tips ..........
  • Page 4: Safety Precautions

    Safety Precautions Safety Precautions Both the installer and the owner and/or operator of the operator panel must read and understand this installation manual. 1. 1 General • Read the safety precautions carefully. • Check the delivery for transportation damage. If damage is found, notify the supplier as soon as possible.
  • Page 5: Disposal Requirementsunder Weee Regulations

    Safety Precautions st andard. : 表示该有害物质在该部件所有均质材料中的含量均在 规定的限 GB/ T 26572-2011 量要求以下。 X: Indicat es t hat t he concent rat ion of t he hazardous subst ance of at least one of all homogeneousmat erials in t he part s is above t he relevant t hreshold of t he GB/ T 26572-2011 st andard.
  • Page 6: Duringinstallation

    Safety Precautions Warning: Bat t ery may explode if mist reat ed. Do not recharge, disassemble or dispose fi of in LA BATTERIEPEUT EXPLOSEREN CASDEMAUVAISEMANIPULATION. NELA RECHARGEZ PAS, NELA DÉMONTEZ PASET NELA JETEZ PASDANSLEFEU. • This product contains a battery; this must only be changed in an area known to be non-hazardous.
  • Page 7: Duringuse

    Replacing the battery incorrectly may result in explosion. Only use batteries recommended by the supplier. During the warranty period, the battery needs to be replaced by an authorized Beijer Electronics service center. Warning: On versionswit h Codesysrunt ime included don’ t replace t he bat t ery bef ore a backup of t he Codesysret ain variablesand cont ent hasbeen made! For more inf ormat ion cont act our l ocal support t eam or look in helponl ine.
  • Page 8: Dismantlingand Scrapping

    Safety Precautions Note: • Cleaning solut ionscont aining bleach, alcohol, and ammonia are corrosive t o fi t ouch panel surf ace coat ingsand ITO l m. So, you should not l eave t he solut ion on t he t ouch panel surf ace f or more t han 2 minut es. Make sure t o remove al l residue fi...
  • Page 9: Namingconvention

    X2 base 5 v2 • X2 pro 7 • X2 control 10 • X2 marine 12 SC • X2 marine 15 HB SC • X2 extreme 7 12V* • X2 extreme 12 HP SC* • X2 extreme 7 SL HP* •...
  • Page 10: Installation

    2. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing. A separate cut out drawing is available for download from the Beijer Electronics web site. For more information, see sections Operator Panel Drawings Technical Data.
  • Page 11 Installation 3. Make sure that the mounting surface of the cutout is smooth and cleaned from any burrs or debris. 4. Install the operator panel into the cutout. 5. Secure the operator panel in position by screwing the slotted thumb screw clockwise, allowing the built-in bracket to flip out and tighten against the cabinet as shown.
  • Page 12: Connectionsto The Controller

    Installation 7. Connect the cables in the specified order, according to the drawing and steps below. Caution: • The operat or panel must be brought t o ambient t emperat ure bef ore it isst art ed up. If condensat ion f orms, ensure t hat t he operat or panel isdry bef ore connect ing it t o t he power out let .
  • Page 13: Other Connectionsand Peripherals

    Installation 3. 2. 2 Other Connectionsand Peripherals Cables, peripheral equipment and accessories must be suitable for the application and its environment. For further details or recommendations, please refer to the supplier. Beij er Electronics, MAEN229...
  • Page 14: Technical Data

    Technical Data Technical Data Parameter X2 marine 15 - B2 HBSC Front panel, W × H × D 410 × 286 × 8 mm Cut out dimensions, 394 × 270 mm W × H Mount ing dept h 53 mm (153 mm including clearance) St andalone mount ing VESA 75 ×...
  • Page 15: Compasssafe Distance

    Technical Data Parameter X2 marine 15 - B2 HBSC Bat t ery BR2032 lit hium bat t ery replaceabl e Power consumpt ion 31. 2 W at rat ed volt age Fuse Int ernal DCf use, 4 AT, 5 × 20 mm Power supply +24 V DC(18–32 V DC)
  • Page 16: Chemical Resistance

    Chemical Resistance Chemical Resistance 5. 1 Metal Casing The frame and casing material is powder-coated aluminum. This powder paint withstands exposure to the following chemicals without visible change: Acet ic acid 10% Phosphoric acid 4% Cit ric acid 10% Phosphoric acid 10% Diesel Sea wat er Dist ill ed wat er...
  • Page 17 Chemical Resistance Solvent Resistance The protective film withstands exposure of more than 24 hours duration under DIN 42 115 Part 2 to the following chemicals without visible change: Acet onit rile Diesel Pet roleum spirit Aj ax / Vim in solut ion Downy / Lenor Phosphoric acid (<30% ) Alkalicarbonat e...
  • Page 18: Touch Screen Surface

    5. 2. 3 Touch Screen Protector For harsh environments and exposure to outdoor conditions, it is recommended to use a protective film to guard the touch screen from damage. This optional part can be ordered from Beijer Electronics. Beij er Electronics, MAEN229...
  • Page 19: Operator Panel Drawings

    Operator Panel Drawings Operator Panel Drawings 6. 1 Connectors Pos. Connector Description Power supply +24 V DC(18–32 V DC) Digit al out Opt o-MOSrelay, 2x SPST. Normally open, isolat ed. USB Host 2. 0, max out put current 500 mA LAN A 10/ 100 Base-T (shielded RJ45) LAN B...
  • Page 20: Digital Outputs

    Operator Panel Drawings Note: In order t o ut ilize t wo communicat ion port s, t he Y-spl it cable CAB109 must be used. In order t o ut ilize t hree communicat ion port st he split cable CAB150 must be used. To use RS-232 and RS-422, use CAB 109.
  • Page 21: X2 Marine 15 - B2 Hbscoutline

    X2 marine 15 - B2 HBSCOutline maximum mater ial thickness 8 mm "Digital IO" not included with X2 pro X2 marine 15-B2 and X2 marine 15-B2 HB Note: fi A St ep CAD le is avail able on t he web sit e www.beij erel ect ronics.com...
  • Page 22: Additional Installation Tips

    Additional Installation Tips Additional Installation Tips When experiencing communication problems in noisy environments or when operating close to temperature limits, the following recommendations are to be noticed. 7. 1 Groundingthe operator panel Mounting plate in the cabinet Door Operator panel Power supply 24 V DC Ferrite core...
  • Page 23: Ethernet Connection In The Operator Panel

    Additional Installation Tips Note: The grounding wiresshould be short and t he conduct or should have a large area. A long, t hin grounding wire hasa very high impedance (resist ance) at high f requencies and doesnot guide dist urbancest o t he ground. Mult i-wire conduct ors are bet t er t han single wire conduct orswit h t he same area.
  • Page 24: To Achieve Better Emcprotection

    7. 3 To Achieve Better EMCProtection • Initially, use the original cabling from Beijer Electronics primarily. • Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC in another. If the cables need to be crossed, cross them at 90°...
  • Page 25: Ambient Temperature

    Additional Installation Tips 1. Use an EMC cable gland or regular plastic cable gland, remove the outer jacket and connect the shield to the installation plate with a 360° metal cable clamp. 2. Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC in another.
  • Page 26 Additional Installation Tips An approximate value of the net power consumption for the operator panel can be calculated by multiplying the supply voltage with the current drawn by the operator panel. This is assuming that all supplied power is transformed to heat. Note: Please ensure t hat t he t emperat ure will not exceed t he maximum ambient operat ing fl...
  • Page 27: Safety

    Additional Installation Tips 7. 5 Safety Power supply 230 V AC to 24 V DC Operator panel +24 V Power supply 230 V AC to 24 V DC Operator panel +24 V Distance? Power supply 230 V AC to 24 V DC Operator panel +24 V Small controller with expansion unit...
  • Page 28: Galvanic Isolation

    Additional Installation Tips 7. 6 Galvanic Isolation The operator panel has galvanic isolation against the 24 V DC power supply but no galvanic isolation between the communication ports for RS-232, RS-422, RS-485, CAN and USB. Only the Ethernet connection has galvanic isolation. Operator panel Modular controller Printer...
  • Page 29 Additional Installation Tips Use external units to improve communication and achieve galvanic isolation. Westermo has good industry-standard insulators that are also insulated from the 24 V DC feed. Note: It isvery import ant t o make sure t hat t he 24 V f eed in t he ext ernal insulat ion unit isnot connect ed t o one of t he communicat ion out l et s.
  • Page 30: Cable And Bustermination Rs-485

    Additional Installation Tips 7. 7 Cable and BusTermination RS-485 • If maximum transfer distance and maximum transfer speed is needed, shielded and twisted pair cable should be used. The mutual capacitance may not exceed 52.5 pF/m, and the cable area should be at least 0.25 mm (AWG24).
  • Page 31: Restrictionsand Recommendations

    Additional Installation Tips 7. 8. 3 Restrictionsand Recommendations • This product supports a maximum bit rate of 500 kBit/s. At this bit rate, the cable length is limited to 50 m. • The maximum supported bit rate depends on bus load, bus topology, number of nodes, bus termination, propagation delay of each CAN node and the bus length.
  • Page 32 fi Head of Beij er Elect ronicsAB Box 426 201 24 Malmö, Sweden www. beij erelect ronics. com / +46 40 358600...

This manual is also suitable for:

B2 hbsc

Table of Contents