NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for
a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by
furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the
Company upon inspection to be of defective material or not of first class workmanship, provided that claim
is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects
are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will
not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith
made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will
not be liable for any damages caused by defective materials or poor workmanship, except for
replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed
or implied in addition to those above stated, except that of title with respect to any of the products or
equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential
damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance
instructions provided are adhered to. The units also must be used for the purpose for which they were
intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions,
Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the
aggravation of existing or prior injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR
GIVEN BY HAWS.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL,
PLEASE CALL:
FOR PARTS CALL:
03/21
E-mail:
haws@hawsco.com
Model SP157.15
Scald Protection Bleed Valve
LIMITED WARRANTY
1-800-766-5612
1-800-640-4297
Model SP157.15
INSTALLATION, OPERATION
MAINTENANCE INSTRUCTIONS
 website:
www.hawsco.com
&
No. 0510001072 (2)
Page 1 of 8

Advertisement

Table of Contents
loading

Summary of Contents for Haws SP157.15

  • Page 1 Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada.
  • Page 2: Location Of Unit

    LOCATION OF UNIT: • The Model SP157.15 Scald Valve Protection Bleed Valve is intended for use only with the 8315CTFP series of emergency showers. • For a scald valve for use with other showers and eyewashes, please see Model 8901B or 8901RFK.
  • Page 3 Installation STEP 1: Unboxing The following components are included with this model. Pertinent installation steps are included for reference. • Scald valve assembly........Step 3 • Barbed tubing tee..........Step 4 • Clear drain tubing piece........Step 4 • Insulation tube..........Step 5 • 3 zip ties for insulation........Step 5 Installation Tip: It is easiest to install this assembly while installing the 8315CTFP-series shower itself;...
  • Page 4 STEP 3: Valve a) Connect and seal the scald valve assembly (use only the obvious wrench flats), orienting the outlet elbow so that it effectively rests against the insulation. If a length of heat trace is running up the side of this insulation, make sure that it stays behind the scald valve elbow and tubing.
  • Page 5: Cleaning Instructions

    STEP 5: Insulation a) Place the insulation around the scald valve, with the radiused end pointing upward and around the inlet plumbing insulation. b) Use both the integral adhesive strips on the insulation to close it up. c) Use the zip ties to further secure the new piece. Tighten each zip tie only enough to close the insulation around the plumbing.
  • Page 6: Troubleshooting

    NOT recommended. c. Replace the valve. Corporation – All Rights Reserved ® 2021 Haws ® HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 03/21 Model SP157A.15 Page 6 of 8...
  • Page 7: Parts Breakdown

    DATE: 03/31/21 SCALE: DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 © 2021 Haws Corporation - All Rights Reserved. HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation. PAGE 7 OF 8...
  • Page 8 DATE: CHK'D.: REVISION 09/17/20 APPROVED: DATE: 03/31/21 SCALE: DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 1 © 2021 Haws Corporation - All Rights Reserved. HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.

Table of Contents