Guardian LUX-V Series Installation & Operation Manual

Guardian LUX-V Series Installation & Operation Manual

Inverter pool & spa heat pump

Advertisement

Quick Links

L U X - V S E R I E S
I N V E R T E R P O O L & S P A H E A T P U MP
I N S T A L L A T I O N & O P E R A T I O N MA N U A L

Advertisement

Table of Contents
loading

Summary of Contents for Guardian LUX-V Series

  • Page 1 L U X - V S E R I E S I N V E R T E R P O O L & S P A H E A T P U MP I N S T A L L A T I O N & O P E R A T I O N MA N U A L...
  • Page 2: Table Of Contents

    LUX-V SERIES INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS FOREWARD ........................................... 3 WARNINGS ......................................... 3 SPECIFICATIONS ......................................... 4 PERFORMANCE DATA ..................................4 DIMENSIONS ......................................5 INSTALL & CONNECTION ....................................6 INSTALLATION DIAGRAM ................................... 6 LOCATION OF INSTALLATION ................................6 PLUMBING OF THE UNIT ..................................6 ELECTRICAL WIRING .....................................
  • Page 3 Your unit should be installed in an outdoor area for maximum performance, for indoor installations contact Guardian for guidance. Check the condensate drain of the heat pump regularly to avoid blockages or debris build up. Keeping it in good order ensures condensation easily drains from the unit.
  • Page 4: Foreward

    The information may change without notice and Guardian is not in any way liable for the accuracy of any information printed and stored or in any way interpreted and used by a user.
  • Page 5: Specifications

    LUX-V SERIES INSTALLATION & OPERATION MANUAL SPECIFICATIONS PERFORMANCE DATA GLV-13 GLV-17 GLV-20 GLV-24 GLV-28 GLV-32T 3.5~13.5 3.8~17.5 5.2~20.6 6.2~24.0 8.5~28.0 10.4~32.0 Heating Capacity (27/24.3˚C) Btu/h 11900~40800 12920~59500 17680~70040 21080~81600 28900~95200 35360~108800 Heating 0.26~2.08 0.27~2.73 0.38~3.17 0.44~3.53 0.60~4.31 0.77~4.92 Power Input C.O.P...
  • Page 6: Dimensions

    LUX-V SERIES INSTALLATION & OPERATION MANUAL DIMENSIONS GLV-13 & GLV-17 A (L) B (W) C (H) Unit: mm 943.5 107.5 GLV-20 & GLV-24 A (L) B (W) C (H) Unit: mm 1115 GLV-28 & GLV-32T A (L) B (W) C (H)
  • Page 7: Install & Connection

    LUX-V SERIES INSTALLATION & OPERATION MANUAL INSTALL & CONNECTION INSTALLATION DIAGRAM Note: Diagram is for reference only. The Heat Pump can be installation can be configured with a bypass system to enable operation of the filtration and sanitation systems to continue while the heat pump is not in use.
  • Page 8: Electrical Wiring

    LUX-V SERIES INSTALLATION & OPERATION MANUAL Standard models have slip glue fittings which accept 40mm or 50mm PCV pipe for connection to the pool or spa filtration plumbing. By using a 50mm to 40mm reducer you can plumb 40mm. CONDENSATION: Since the heat pump cools down the air from 4-5˚C, water may condense on the fins of the evaporator.
  • Page 9: Use & Operation

    LUX-V SERIES INSTALLATION & OPERATION MANUAL USE & OPERATION THE CONTROL PANEL POWER Start or shut down the unit, cancel the current operation, return to the previous menu. MODE Switch between unit modes, temperature settings & parameter settings. CLOCK User clock & timer settings.
  • Page 10: Switching Modes

    LUX-V SERIES INSTALLATION & OPERATION MANUAL 4.2.2 SWITCHING MODES Cooling Auto Heating From the main menu, press the MODE button to switch the unit among heating, cooling and automatic mode. The mode change will automatically save after 2 seconds of idle operation.
  • Page 11: Timer Settings

    LUX-V SERIES INSTALLATION & OPERATION MANUAL 4.2.5 TIMER SETTINGS 4.2.5.1 SETTING ON/OFF TIMER Select a timer using the arrow keys, then The hour digit will be flashing indicating is Hold CLOCK to enter timer settings CLOCK to adjust time. changeable...
  • Page 12: Silent Settings

    LUX-V SERIES INSTALLATION & OPERATION MANUAL 4.2.6 SILENT SETTINGS 4.2.6.1 SETTING A SILENT TIMER From the main menu, press and hold the SILENT key for 2 seconds. This menu will allow you to set a single timing period of reduced noise from the unit.
  • Page 13: Troubleshooting Guide

    LUX-V SERIES INSTALLATION & OPERATION MANUAL TROUBLESHOOTING GUIDE Electronic Control Fault Table Malfunction Display Cause Solution The temp. sensor is broken or Inlet temp. sensor fault Check or change the temp. sensor short circuit The temp. sensor is broken or Outlet temp.
  • Page 14 LUX-V SERIES INSTALLATION & OPERATION MANUAL Frequency Conversion Board Fault Table Fault Protection/fault Reason Elimination methods display Drv1 MOP alarm MOP drive alarm Recovery after the 150s Frequency conversion board and Inverter offline Check the communication connection mainboard communication failure...
  • Page 15: Wi-Fi Operation

    WI-FI OPERATION INTRODUCTION The Guardian Handy Heat Pump app is available as a standard inclusion on the Guardian Lux-V, Platinum & EcoPro series. Available for iOS and Android, the smart phone controller app offers you an easy and convenient way to monitor and control your pool temperature, as well as adjust settings, set timers, receive error alerts &...
  • Page 16: App Setup

    LUX-V SERIES INSTALLATION & OPERATION MANUAL APP SETUP 5.3.1 CREATE AN ACCOUNT Fig. 2: Home Page Fig. 1: Login Menu Fig. 3: Forgot Password Menu 1. You need to create an account to use the app. To register, press the Account Registration button & fill in your details.
  • Page 17 LUX-V SERIES INSTALLATION & OPERATION MANUAL Once you have logged in, you will enter the My Device screen (Fig.4) where you can add your device and set up the wi-fi connection. Note: ensure your Bluetooth is turned on in your phone settings and enabled in the app settings. The app will ask for permission to use Location, Camera &...
  • Page 18: Device Management

    LUX-V SERIES INSTALLATION & OPERATION MANUAL 5. Once you have linked the correct barcode, you can complete the connection and name your device if required (e.g. Holiday Home Heater). 6. Once complete, you will enter the device management menu (Fig. 14) where you can go into the unit to view and adjust the settings.
  • Page 19 LUX-V SERIES INSTALLATION & OPERATION MANUAL Fig. 16: Modify Target Temperature Fig. 17: Main Menu Fig. 18: Right-Hand Menu Fig. 19: Mode Menu Fig. 20: Timer Settings Fig. 21: Troubleshooting Menu Page 18...
  • Page 20: Maintenance & Inspection

    LUX-V SERIES INSTALLATION & OPERATION MANUAL MAINTENANCE & INSPECTION Check that the heat pump has good water flow. Avoid the condition of no water or air entering the system, this will influence unit's performance and reliability. You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty or clogged filter.
  • Page 21 LUX-V SERIES INSTALLATION & OPERATION MANUAL The following checks shall be applied to installations using flammable refrigerants: • The charge size is in accordance with the room size within which the refrigerant containing parts are installed; • The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;...
  • Page 22 LUX-V SERIES INSTALLATION & OPERATION MANUAL DETECTION OF FLAMMABLE REFRIGERANTS Under no circumstances should potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) must not be used.
  • Page 23 LUX-V SERIES INSTALLATION & OPERATION MANUAL The recovery equipment must be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales must be available and in good working order.
  • Page 24: Appendix

    LUX-V SERIES INSTALLATION & OPERATION MANUAL APPENDIX CABLE SPECIFICATIONS Cable specifications must meet local regulations and be supplied by a qualified electrician. REFRIGERANT SATURATION TEMPERATURE Comparison table of refrigerant saturation temperature. Pressure (MPa) Temperature (R410A)(˚C) -51.3 Temperature (R32)(˚C) -52.5 29.5 33.3...
  • Page 25 LUX-V SERIES INSTALLATION & OPERATION MANUAL Connections explained: Sign Meaning P10-1/2/3(U/V/W) Compressor CN66 Compressor signal CN97 DC motor CN11 4-way valve CN18 Water pump CN13 Reserved P1 P2 Live wire Neutral wire CN10 Program download interface RS485 Color line controller communication/WiFi...
  • Page 26: Wiring Diagrams

    LUX-V SERIES INSTALLATION & OPERATION MANUAL WIRING DIAGRAMS Page 25...
  • Page 27 LUX-V SERIES INSTALLATION & OPERATION MANUAL Page 26...
  • Page 28 LUX-V SERIES INSTALLATION & OPERATION MANUAL Page 27...
  • Page 29: Warranty Terms

    Warranty Registration Form 5. Onsite technical service is available within a 25km radius of your Guardian Service Agents. Service outside this area will incur a traveling fee.

This manual is also suitable for:

Glv-13Glv-17Glv-20Glv-24Glv-28Glv-32t

Table of Contents