D-M-E VCTB-4000 User Manual page 8

Four zone, 24 volt dc valve gate controller
Table of Contents

Advertisement

NOTE: TRIGGER INPUT #5 (Customer Connection to Trigger signal dry contact – Injection Forward)
Note: Valve Output Valve # 4 Above
PINS 1, 2, 3 and 4 supply +24 VDC Control power to valves 1, 2, 3 and 4, respectively. PIN 13 supplies
ground to all of the valves.
D-M-E Company
4
5
TOP PLATE
1. Power switch
2. Main Fuses: replace with
Bussman ABC-3 only!
3. Power Entry Cord
4. Valve Output Connector
5. Trigger Signal Input
Trigger Signal Connection
VCTB-4000
ED-0109-OT-024-( Preliminarry Rev E)
2
1
2
Black
A
Red
C
B
Shield
3
Page 8