OWNER/OPERATOR
RESPONSIBILITY
It is the owner/operator responsibility to
properly use and maintain this equipment.
The instructions and warning contained in
this manual shall be read and understood
by the owner/operator prior to operating
this equipment.
If an owner/operator does not under-stand
English, the contents of this manual shall be
explained in the owner/operators native
language to assure that the owner/operator
comprehends.
The owner/operator shall retain this manual
for future reference to important warnings,
operating and maintenance instructions.
NOTICE
This device dispenses fluid using pressur-
ized air, and complies with the specifica-
tions of the Uniform Fire Code, Standard
Fire Prevention Code and the National Fire
Protection Association, (NFiPA-30). It does
not comply with current provisions of BOCA
section F-3203.5.3. You should consult
your local fire marshall concerning code
compliance of this device.
INSPECTION
Prior to operation or maintenance, a visual
inspection shall be made. Check for worn
parts, air leaks, damaged, loose or missing
parts.
Check tank operation by connecting air to
air nipple and closing ball valve. Verify that
there is sufficient air flow coming from
nozzle/hose assembly.
If the 3653 is damaged, badly worn or
operates abnormally, it should be removed
from service. Contact a factory authorized
service center for repair.
An annual tank/component inspection is
recommended to be performed by a factory
authorized service center.
August 2003
USED ANTI-FREEZE RECEIVER
OWNER/OPERATOR MANUAL
To drain anti-freeze: With
valve fully open, (Valve
handle in vertical position),
raise drain bowl to desired
height and lock in place.
Drain anti-freeze into bowl/
tank assembly. Check sight
gauge tube on back side of
tank frequently. DO NOT fill
tank above maximum anti-
freeze level as shown.
Failure to heed the following warning may
result in personal injury and/or property
damage. Pop-off valve and preset, non
adjustable regulator have been installed
for your protection. Do not tamper with or
remove.
Failure to heed the following may result in
personal injury and/or property damage.
NEVER leave unit unattended when oper-
ating or evacuating.
NEVER use near open flame or heat
source.
ALWAYS raise drain bowl and close main
valve before emptying.
ALWAYS disconnect air supply after emp-
tying.
NEVER use unit for handling highly volatile
fuels and fluids.
USE ONLY the nozzle assembly provided.
One Lincoln Way
St. Louis, MO 63120-1578
Phone +1.314.679.4200
Fax +1.800.424.5359
MODEL 3653 - SERIES "A"
To transport tank: With
valve fully open, (Valve
handle in vertical position),
lower drain bowl to desired
height. Always use the tank
handle to transport the tank
assembly.
SAFETY INSTRUCTIONS
•
NEVER pressurize tank with ball valve
open.
If used antifreeze does not evacuate
•
tank upon pressurization; check that ball
valve is fully closed, (handle in horizon-
tal position). If this does not correct the
problem remove the unit from service
immediately and contact an authorized
service center for repair.
If the pop-off valve ever relieves ANY
•
air pressure from the tank, remove the
unit from service immediately and
contact an authorized service center for
repair.
© Copyright 2003
Printed in USA
Web site:
www.lincolnindustrial.com
To evacuate anti-freeze:
Evacuate used anti-freeze
from tank when maximum
anti-freeze level is obtained.
DO NOT overfill tank above
maximum anti-freeze level as
shown above. Raise drain
bowl and lock in place, close
valve fully, (Valve handle in
horizontal position), and
place nozzle SECURELY into
used anti-freeze collection
reservoir. Connect air to inlet
nipple and discharge anti-
freeze. Never leave unit
unattended when evacuating
anti-freeze. Immediately dis-
connect air supply when
anti-freeze is no longer
discharging into reservoir.
- B4
Section
- 25
Page
Form 403326
Need help?