Running hour meter

Advertisement

Menu operation (single display device):
All adjustments are made via the three front mounted buttons.
Press the "MENU" button repeatedly until the desired setting is reached, press "SELECT" to display the current value of the
selected parameter, or sub menu (if applicable).
The "+" and "-" buttons are used to change the value.
"ENTER" will return the device to the menu.
The "BACK" button will exit the menu.
Menu operation (dual display device):
Press the menu " " button repeatedly until the desired setting is reached.
The " " and " " buttons are used to change the value.
" " will display the next menu item.
To exit the menu hold " " button for 3 seconds.
Menu options:
Exit the menu before making the following adjustments.
Lock / unlock parameters:
(default: unlocked)
Press "BACK" (" "), then "ENTER" (" ") and hold the 2 buttons until the desired option is displayed.
The display cycles between "Loc" (no changes allowed) & "u.Loc" (parameters may be adjusted)
Full / reduced menu (default: Full)
Press "SELECT"(" "), then "ENTER"(" ") and hold the 2 buttons until the desired option is displayed.
The display cycles between "rEdu" (limited menu) & "Full" (all parameters are accessible)
Access Code: (default: no code)
Once the above options have been set as required, Press "BACK" and "SELECT" (" " and " ") simultaneously until "CODE" is
displayed.
Now use the "+" & "-" (" " and " " ) to enter a code.
Once a code is entered, access to the options above is not permitted.
To clear the code, re-enter the same code again.
If the code is forgotten. Press and hold "+" & "-" (" " and " " ) until "CODE" is displayed while re-applying power to the device.
Please Note ( for 1 and 2 relay devices ONLY):
·
As a power saving feature, the display dims if settings are not being made.
·
Even though the device seems to operate correctly, the relay(s) will not energise if the input voltage is below the operating
voltage.
12 Month guarantee:
Our product is guaranteed for a 12 (twelve) month period from date of purchase. This guarantee is valid for defects arising from
failure during specified conditions. This guarantee does not cover damage due to abuse, tampering or improper installation. Our
company does not accept liability for any consequential damage or loss arising from product malfunction. Should this product
prove to be defective, kindly return for inspection or repair.
Relay specifications:
Contact rating:
10A 250 VAC 2500VA
Mechanical life:
30 million operations
Electrical life:
250 000 operations (at maximum load)