Page 1
“The Drain Cleaning Machine & Equipment Specialist” “The Drain Cleaning Machine & Equipment Specialist” GO 4000 • GO 3500 • GO 3000 • GO 1500A • GO 1500 “The Drain Cleaning Machine & Equipment Specialist” “The Drain Cleaning Machine & Equipment Specialist”...
Page 2
Save the receipt, warranty, and this manual. It is important that you read the entire manual to become familiar with this product before you begin using it. This drain cleaner is designed for certain applications only. Gorlitz Sewer & Drain Inc. is not responsible for issues arising from modification or improper use of this product such as an application for which it was not designed.
• THE 25 FOOT LONG POWER SUPPLY CORD IS PROVIDED WITH A BUILT IN GROUND FAULT CIRCUIT INTERRUPTER (GFCI). FOR MAXIMUM PROTECTION AGAINST ELECTRICAL SHOCK HAZARD, TEST YOUR GFCI REGULARLY. • AVOID SPRAYING, DOUSING THE MOTOR OR ELECTRIC CONTROLS WITH WATER. Gorlitz Jetters Operating & Maintenance Manual...
Page 4
BATTERY CHANGING INSTRUCTIONS. UNCRATING AND CHECKING CONTENTS GORLITZ JETTERS ARE SHIPPED ASSEMBLED. IN ORDER TO FACILITATE PACKAGING, CERTAIN ITEMS ARE NOT ATTACHED TO EQUIPMENT AND MUST BE ASSEMBLED BY PURCHASER. DUE TO SHIPMENT AND HOW THEY ARE HANDLED BY VARIOUS FREIGHT COMPANIES, INSPECTION OF ALL ITEMS AND CHECKING FOR LOOSE BOLT CONNECTIONS OR DAMAGED PARTS IS RECOMMENDED.
LUBRICATION GORLITZ JETTERS SHOULD BE GIVEN THE BEST OF CARE. IF KEPT CLEAN AND LUBRICATED, THEY CAN PROVIDE MANY YEARS OF TROUBLE-FREE SERVICE. THE FOLLOWING INSTRUCTIONS SHOULD BE CAREFULLY OBSERVED AT ALL TIMES: • OIL OR GREASE ALL POINTS WHERE FRICTION EXIST BETWEEN TWO OR MORE MOVING PARTS.
MORE PRESSURE AND “OUT’ FOR LESS PRESSURE READING. SOME UNITS ARE ALSO EQUIPPED WITH A THERMAL RELIEF VALVE WHICH AUTOMATICALLY RELIEVES PRESSURE. WHEN THE TEMPERATURE RISES TO HIGH. PRESSURE SETTINGS: 3000 PSI MAXIMUM FOR 389 cc MODELS 3500 PSI MAXIMUM FOR 688 cc MODELS Gorlitz Jetters Operating & Maintenance Manual...
3250 PSI (3500 PSI MAXIMUM) FOR 688 cc GASOLINE MODELS MACHINE SETUP CHECK LIST GORLITZ JETTERS SHOULD BE GIVEN THE BEST OF CARE. IF KEPT CLEAN AND LUBRICATED, THEY CAN PROVIDE MANY YEARS OF TROUBLE-FREE SERVICE. THE FOLLOWING INSTRUCTIONS SHOULD BE CAREFULLY OBSERVED AT ALL TIMES: •...
Page 8
TO ROTATE OR TWIST THE HOSE NEAR THE DRAIN OPENING. ONCE YOU HAVE CUT THROUGH THE BLOCKAGE, PULL HOSE BACK SEVERAL FEET. PASS HOSE AGAIN THROUGH SAME STOPPAGE LOCATION AND ADVANCE TO NEXT LARGER DRAIN LINE CONNECTION. SLOWLY RETRIEVE HOSE FROM DRAIN PIPE TO ALLOW A THOROUGH CLEANING JOB. Gorlitz Jetters Operating & Maintenance Manual...
Page 9
NEVER PERMIT PUMP TO RUN DRY AND NEVER SPRAY ACIDS OR ABRASIVE FLUIDS! PARTIAL ENGINE VIEW (GASOLINE MODELS) ENGINE SWITCH THROTTLE LEVER CHOKE LEVER CLOSED GAS LEVER ON QAE TYPE ENGINE SWITCH CARBURETOR (OPTIONAL) Gorlitz Jetters Operating & Maintenance Manual...
Page 10
CONNECTOR BYPASS HOSE PULSATOR WATER KNOB DISCHARGE CONNECTOR WATER PUMP ASSEMBLY (3500 SERIES) PRESSURE BYPASS TO WATER GAUGE HOSE DISCHARGE VALVE POP-OFF VALVE WATER INLET CONNECTOR PUMP BODY PULSATOR KNOB BACK FLOW CHECK VALVE Gorlitz Jetters Operating & Maintenance Manual...
PULLING AIR AT INLET LINE LOW WATER REPLACE DEFECTIVE PART DEFECTIVE SPRING PLUNGER OR SEAL PRESSURE CLEAN VALVE ASSEMBLY. REFER TO ASSEMBLY MANUFACTURERS REPAIR AND PARTS OVERSIZED OR WORN NOZZLE ASSEMBLY MANUAL CHECK FOR PROPER SIZE Gorlitz Jetters Operating & Maintenance Manual...
Page 12
REPLACE PLUNGER SCORED OR CRACKED PLUNGERS FREQUENT OR EXCESSIVE WATER TEMPERATURE LOWER WATER TEMPERATURE PREMATURE FAILURE OF THE EXCESSIVE DISCHARGE PRESSURE REDUCE PRESSURE TO SPECIFICATION PACKING RUNNING PUMP DRY DO NOT RUN PUMP WITHOUT WATER Gorlitz Jetters Operating & Maintenance Manual...
Page 20
(1) year from date of purchase to original buyer. If any parts break or fail, we ask you to notify your nearest dealer or Gorlitz Sewer & Drain, Inc. and supply us with proof of purchase and nature of failure.