COE-8 is a system for transporting switch closure information over a TCP/IP network. The COE-8
consists of two devices, and Transmitter Unit (COE-8I) and a Receiver Unit (COE-8O). The COE-8I
provides 8 inputs for switch contacts, relay closures or DC Voltage. Upon a change of state for any
channel, it will transmit a message to one or more (up to 32) COE-8O units. The COE-8O has eight
relays that will mirror the status of the eight inputs of the COE-8I.
configured from a Web Browser.
Switch or Relay
Contacts
In Here.....
COE-8 I
Each channel of the COE-8I is independently configurable, allowing selection of what IP addresses to
deliver to and on what channel. Highly flexible telemetry systems can be developed with these simple
devices. The COE-8 system also supports SNMP for independent monitoring and control. Up to 4 SNMP
managers can be configured to support the COE-8.
REF: CTL\COE8_IO_060707e.DOC
TCP/IP over 10base-T
Setup and Status
Monitoring via
Web Browser
Technical Support Hotline: (201) 967-8788
Technical Support: 201-934-5111
Main: 201-934-9944
Contact Closure Over Ethernet
Models COE-8I, COE-8O
Each unit can be monitored and
..... Relay
Contacts
Out Here
COE-8O
tech@dataprobe.com
Website: dataprobe.com

Advertisement

loading

Summary of Contents for Dataprobe COE-8

  • Page 1 Highly flexible telemetry systems can be developed with these simple devices. The COE-8 system also supports SNMP for independent monitoring and control. Up to 4 SNMP managers can be configured to support the COE-8.
  • Page 2: Hardware Installation

    Connect the network to the connector provided. A yellow LED indicates a successful connection to the network, a green LED data activity. Power Apply power only when the cover is secured onto the COE-8. Use RELAY OUTPUT only the wall mounted power supply provided. For applications N.O.
  • Page 3: Initial Power-Up

    WEB Page Access The web pages provide status information on the inputs and outputs of the COE-8, as well as provide configuration for the unit. Open a browser to the default or current IP address of the unit. Enter the...
  • Page 4 2) DHCP WEB Page Login to the COE-8 and access the Setup pages by clicking on the Setup button from the home page. Click on the IP button to bring up the IP Settings page: Select Static Mode from the radio buttons and fill in the IP Address, Subnet Mask and Gateway as provided by your network administrator.
  • Page 5 If a port other than the default Port 80 is used for web browser access, that port must specifically be used in the URL when accessing the COE-8. For example, if the Web Port is changed to 9090 then the URL for the unit would be http://192.168.1.254:9090...
  • Page 6 Enter the IP addresses of up to 4 SNMP managers. Enable or Disable SNMP with the checkbox provided. Traps can be sent every time there is a change of state on any COE-8 channel. Check the box provided to enable this. If both the COE-8I and COE-8O are configured to send traps, two messages will be received by each SNMP manager for each event.
  • Page 7: Warranty

    Page 7 TECHNICAL SUPPORT, RETURNS and WARRANTY Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of this product. To obtain Technical Support call our Tech Support Hotline at 201-967- 8788, or Email us at tech@dataprobe.com. Please have the following information available when you call: •...