IFM DV2900 Operating Instructions Manual
IFM DV2900 Operating Instructions Manual

IFM DV2900 Operating Instructions Manual

20-led light tower

Advertisement

Quick Links

Operating instructions
GB
20-LED light tower
DV2900
DV2910
DV2920
DV2930

Advertisement

Table of Contents
loading

Summary of Contents for IFM DV2900

  • Page 1 Operating instructions 20-LED light tower DV2900 DV2910 DV2920 DV2930...
  • Page 2: Table Of Contents

    DV2900 DV2910 DV2920 DV2930 20-LED light tower Contents Preliminary note .............
  • Page 3: Preliminary Note

    20-LED light tower DV2900 DV2910 DV2920 DV2930 1 Preliminary note You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at www.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications...
  • Page 4: Safety Instructions

    DV2900 DV2910 DV2920 DV2930 20-LED light tower 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
  • Page 5: Intended Use

    The unit is not suited for environments with particular requirements on mechanical stability (e.g. shock/vibration). The unit is intended for indoor use only. u Observe the operating conditions (Ò Technical data at www.ifm.com). The unit is not approved for safety-related tasks in the field of operator protection.
  • Page 6: Function

    The IODDs necessary for the configuration of the unit, detailed information about process data structure, diagnostic information, parameter addresses and the necessary information about the required IO-Link hardware and software can be found at www.ifm.com.
  • Page 7: Installation

    Attach the fixture for the device to the mounting surface using the supplied M4 nuts. Tightening torque 1.8 Nm. u Only with the models DV2900 and DV2910: For mounting on a horizontal surface attach the base to the fixture (overlapping marks on base and fixture) and turn clockwise by approx.
  • Page 8: Electrical Connection

    DV2900 DV2910 DV2920 DV2930 20-LED light tower 6 Electrical connection The unit must be connected by a qualified electrician. Observe the national and international regulations for the installation of electrical equipment. Voltage supply according to SELV, PELV. The IO-Link port must be connected according to the IO-Link specification.
  • Page 9: Operating And Display Elements

    20-LED light tower DV2900 DV2910 DV2920 DV2930 7 Operating and display elements 7.1 Signal Light Mode Segment 1 with 4 RGB LEDs as factory setting (number and size of the LED segment can be configured) Segment 2 with 4 RGB LEDs as factory setting (number and size of the LED segment can be configured)
  • Page 10: Level Meter Mode

    DV2900 DV2910 DV2920 DV2930 20-LED light tower 7.2 Level Meter Mode LED 20 as factory setting (direction of movement of LED control can be configured) LED 1 as factory setting (direction of movement of LED control can be configured) Buzzer (only DV2910 and DV2930)
  • Page 11: Operation

    20-LED light tower DV2900 DV2910 DV2920 DV2930 8 Operation Connect the unit to an IO-Link master (master port class A) using a 4-pole connection cable. The controller switches the individual LEDs / LED segments on and off in the configured colours according to the set parameters.
  • Page 12: User-Specific Colour Combinations

    DV2900 DV2910 DV2920 DV2930 20-LED light tower Position Threshold value Colour Flashing frequency LED 20 1 (red) Blinking fast LED 19 1 (red) Blinking fast LED 18 1 (red) Blinking fast LED 17 1 (red) Blinking fast LED 16 5 (orange)
  • Page 13 20-LED light tower DV2900 DV2910 DV2920 DV2930 If a number from 1-3 is sent in the process data (byte 0, bit 1+2), the current display of the segments / LEDs is overwritten with the selected colour combination Bank 1, 2 or 3. For example, in Level Meter...
  • Page 14: Parameter Setting

    Depending on the parameter setting, the parameters available in the menu may change. Requirements for parameter setting via the IO-Link interface: ü A suitable parameter setting software, e.g. ifm moneo|configure ü The Input Output Device Description (IODD) for the device, see documentation.ifm.com...
  • Page 15: Operating Mode

    20-LED light tower DV2900 DV2910 DV2920 DV2930 9.2.1 Operating mode Setting of the operating mode • Signal Light Mode (Ò / 11) • Level Meter Mode (Ò / 11) Factory setting: Signal Light Mode 9.2.2 LED Intensity Setting of the LED brightness • 0…100 Factory setting: 70 9.2.3 Buzzer Intensity...
  • Page 16: Segment Colors. Segment X

    DV2900 DV2910 DV2920 DV2930 20-LED light tower • Activated • Deactivated (factory setting) This parameter is only available in Signal Light Mode. 9.2.9 Segment colors. Segment x Colour definition for all LEDs in this segment • • Red (factory setting for segment 1) •...
  • Page 17: Scope Of Appearance

    20-LED light tower DV2900 DV2910 DV2920 DV2930 • From bottom to top (factory setting) • From top to bottom This parameter is only available in Level Meter Mode. 9.2.13 Scope of appearance Setting of the colour and flashing frequency for the LEDs that are activated by exceeded thresholds •...
  • Page 18: Led Colors. Led X

    DV2900 DV2910 DV2920 DV2930 20-LED light tower Threshold value This parameter is only available in Level Meter Mode. 9.2.15 LED Colors. LED x Colour definition for this LED For each LED, 1 of 21 colours or the switched off state can be configured.
  • Page 19: Maintenance, Repair And Disposal

    20-LED light tower DV2900 DV2910 DV2920 DV2930 10 Maintenance, repair and disposal Cleaning the unit: u Disconnect the unit from the voltage supply. u Clean the unit from dirt using a soft, chemically untreated and dry micro-fibre cloth. The operation of the unit is maintenance-free.

This manual is also suitable for:

Dv2910Dv2920Dv2930

Table of Contents