20-LED light tower DV2900 DV2910 DV2920 DV2930 1 Preliminary note You will find instructions, technical data, approvals and further information using the QR code on the unit / packaging or at www.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications...
DV2900 DV2910 DV2920 DV2930 20-LED light tower 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. – The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
The unit is not suited for environments with particular requirements on mechanical stability (e.g. shock/vibration). The unit is intended for indoor use only. u Observe the operating conditions (Ò Technical data at www.ifm.com). The unit is not approved for safety-related tasks in the field of operator protection.
The IODDs necessary for the configuration of the unit, detailed information about process data structure, diagnostic information, parameter addresses and the necessary information about the required IO-Link hardware and software can be found at www.ifm.com.
Attach the fixture for the device to the mounting surface using the supplied M4 nuts. Tightening torque 1.8 Nm. u Only with the models DV2900 and DV2910: For mounting on a horizontal surface attach the base to the fixture (overlapping marks on base and fixture) and turn clockwise by approx.
DV2900 DV2910 DV2920 DV2930 20-LED light tower 6 Electrical connection The unit must be connected by a qualified electrician. Observe the national and international regulations for the installation of electrical equipment. Voltage supply according to SELV, PELV. The IO-Link port must be connected according to the IO-Link specification.
20-LED light tower DV2900 DV2910 DV2920 DV2930 7 Operating and display elements 7.1 Signal Light Mode Segment 1 with 4 RGB LEDs as factory setting (number and size of the LED segment can be configured) Segment 2 with 4 RGB LEDs as factory setting (number and size of the LED segment can be configured)
DV2900 DV2910 DV2920 DV2930 20-LED light tower 7.2 Level Meter Mode LED 20 as factory setting (direction of movement of LED control can be configured) LED 1 as factory setting (direction of movement of LED control can be configured) Buzzer (only DV2910 and DV2930)
20-LED light tower DV2900 DV2910 DV2920 DV2930 8 Operation Connect the unit to an IO-Link master (master port class A) using a 4-pole connection cable. The controller switches the individual LEDs / LED segments on and off in the configured colours according to the set parameters.
DV2900 DV2910 DV2920 DV2930 20-LED light tower Position Threshold value Colour Flashing frequency LED 20 1 (red) Blinking fast LED 19 1 (red) Blinking fast LED 18 1 (red) Blinking fast LED 17 1 (red) Blinking fast LED 16 5 (orange)
Page 13
20-LED light tower DV2900 DV2910 DV2920 DV2930 If a number from 1-3 is sent in the process data (byte 0, bit 1+2), the current display of the segments / LEDs is overwritten with the selected colour combination Bank 1, 2 or 3. For example, in Level Meter...
Depending on the parameter setting, the parameters available in the menu may change. Requirements for parameter setting via the IO-Link interface: ü A suitable parameter setting software, e.g. ifm moneo|configure ü The Input Output Device Description (IODD) for the device, see documentation.ifm.com...
DV2900 DV2910 DV2920 DV2930 20-LED light tower • Activated • Deactivated (factory setting) This parameter is only available in Signal Light Mode. 9.2.9 Segment colors. Segment x Colour definition for all LEDs in this segment • • Red (factory setting for segment 1) •...
20-LED light tower DV2900 DV2910 DV2920 DV2930 • From bottom to top (factory setting) • From top to bottom This parameter is only available in Level Meter Mode. 9.2.13 Scope of appearance Setting of the colour and flashing frequency for the LEDs that are activated by exceeded thresholds •...
DV2900 DV2910 DV2920 DV2930 20-LED light tower Threshold value This parameter is only available in Level Meter Mode. 9.2.15 LED Colors. LED x Colour definition for this LED For each LED, 1 of 21 colours or the switched off state can be configured.
20-LED light tower DV2900 DV2910 DV2920 DV2930 10 Maintenance, repair and disposal Cleaning the unit: u Disconnect the unit from the voltage supply. u Clean the unit from dirt using a soft, chemically untreated and dry micro-fibre cloth. The operation of the unit is maintenance-free.