Officine Gullo BBSC4E Instructions Manual

Officine Gullo BBSC4E Instructions Manual

Eelectric direct grill for residential and professional use

Advertisement

Quick Links

INSTRUCTIONS
FOR INSTALLATION AND USE
BBSC4E
EELECTRIC DIRECT GRILL
FOR RESIDENTIAL AND PROFESSIONAL USE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BBSC4E and is the answer not in the manual?

Questions and answers

Summary of Contents for Officine Gullo BBSC4E

  • Page 1 INSTRUCTIONS FOR INSTALLATION AND USE BBSC4E EELECTRIC DIRECT GRILL FOR RESIDENTIAL AND PROFESSIONAL USE...
  • Page 2 14. In case of failure or malfunction, turn the appliance off, close the gas supply valve and do not attempt to carry out any repairs, which must be done exclusively by an authorized service center. Request the use of original spare parts only. Failure to comply with the above recommendations may compromise the appliance’s safety. Officine Gullo...
  • Page 3: Table Of Contents

    CLEANING AND MAINTENANCE ..................8 WHAT TO DO IN THE EVENT OF A BREAKDOWN ..............9 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ..9 MAINTENANCE (only for qualified personnel) ................9 ACCESSIBILITY ........................9 Officine Gullo...
  • Page 4: Installation Manual

    INSTALLATION MANUAL Fig. A BBSC4E E. Electrical connection Officine Gullo...
  • Page 5 Fig. B SCHEMA ELETTRICO – SCHALTPLAN – SCHEMA ELECTRIQUE - WIRING WIRING DIAGRAM DIAGRAM – ESQUEMA ELECTRICO BBSC4E FIG. B CWK…-74ET 400V~3N 50/60Hz Micro switch Resistance Microinterruttore Mikroschalter Micro interrupteur Micro switch Microinterruptor Power terminal block White pilot light Morsettiera...
  • Page 6: Declaration Of Compliance

    DECLARATION OF COMPLIANCE This appliance is manufactured by OFFICINE GULLO S.r.l Headquarters and factory Via Della Torricella 29, Antella, Bagno a Ripoli 50012 Florence - Italy Tel. +39 055 65 60 3324 +39 055 62 18 07 officinegullo.com | info@officinegullo.com...
  • Page 7: Electric Connection

    Absorb. Power supply MODEL Power supply Consumption max kW max A cable (Indicative) BBSC4E 40x70x29 h 400Vac/3N 50/60 Hz 4,08 5,91 5x1,5 mm² 1 lt/h ELECTRIC CONNECTION The appliance is supplied without the connection cable. In the event that it has to be substituted, proceed as follows: •...
  • Page 8: User Manual

    (the green colored type used for washing dishes). It is recommended that the metal be rubbed, uniformly applying light pressure, until the desired effect is achieved. Officine Gullo...
  • Page 9: What To Do In The Event Of A Breakdown

    To get to the junction box, remove the back of the appliance. The control elements are reached from the front control panel; unscrew the black cap of the water outlet lever, unscrew the fixing screws from the control panel and remove Officine Gullo...