  • Page 1 INSTRUCTION MANUAL Particle measuring system pSYS Version 1.4 / 30.01.2023...
  • Page 2: Table Of Contents

    Mounting particle sensors in the measuring range ................10 Mount a temperature and humidity sensor in measuring range ............11 Connecting sensors to the pSYS ....................... 12 Connecting pSYS to the power supply ....................12 Accessing the cloud and displaying measured values ................. 12 Technical data ......................... 14...
  • Page 3: Legal Notice

    Legal notice 1 Legal notice Warning concept This manual contains information that you must observe for your personal safety and to prevent damage to property. Warnings are presented in decreasing order of hazard level as follows: DANGER Indicates a direct hazard for humans. Irreversible injuries or death will result if not observed.
  • Page 4 If third-party products and components are used, they must be recommended or approved by in.hub. Proper storage, setting up, assembly, installation, commissioning, operation, and maintenance are essential for the correct and safe operation of the product.
  • Page 5: General Information

    The pSYS particle measuring system is available in three versions: pSYS Compact, pSYS Comfort, and pSYS Business Edition. Plan how you want to use the particle measuring system or contact us to find out which system is best suited for your application. The models differ mainly in the number of connections for the sensors, the accessories, and the way the system is provided.
  • Page 6: General Instructions For Use

    1 x Cold device cable 1 x Instruction Manual (PDF) 2.2 General instructions for use in.hub GmbH assumes no liability for malfunctions of the device resulting from improper handling, mechanical damage, incorrect application, and use other than for the intended purpose.
  • Page 7: Service & Support

    General information 2.7 Service & Support If you have any questions about specific use cases or about technical parameters, please contact us. Mail: service@inhub.de Phone: +49 371 5347 825 (Technical Sales Staff) These details will connect you with the appropriate contact.
  • Page 8: Product Information

    Product information 3 Product information The particle measuring system pSYS is a plug & play solution for continuous and gapless detection and evaluation of dust concentrations of dust classes PM 1 to PM 10 at up to 5 measuring points.
  • Page 9: Software

    Connection socket for cold device cable (power supply) Supply voltage of 24 V ± 10 % 3.2 Software The pSYS particle measuring system is equipped with in.hub's own operating system SIINEOS. All necessary settings are already configured for you. Further adjustments can only be made by in.hub.
  • Page 10: Assembly And Commissioning

    Assembly and commissioning 4 Assembly and commissioning The pSYS particle measuring system is designed for mounting in indoor industrial environments. ATTENTION Mount the unit horizontally or vertically with the mounting tabs located on the housing above floor level to ensure safe use.
  • Page 11: Mount A Temperature And Humidity Sensor In Measuring Range

    Assembly and commissioning 2. Plug the cable into the sensor to enable data transmission and power supply. Fig. 3: Connection of sensor cable to particle sensor The coding pins on the sides of the connector allow only one correct installation position.
  • Page 12: Connecting Sensors To The Psys

    4. Select the particle measuring system. A standard dashboard opens with diagrams (so-called widgets) already preconfigured by in.hub, e.g., for the mean values. With correct commissioning, it takes approx. 2 minutes until the measured values are displayed.
  • Page 13 Assembly and commissioning Fig. 5: Example of a dashboard in the Telekom Cloud (in German) You can edit the dashboard and, for example, change the name, customize the view, but also delete the dashboard or add more dashboards. NOTE: For extended functionalities, e.g., the data explorer, you need special access rights that are not included in your standard user account.
  • Page 14: Technical Data

    1 x service interface, 1 x temperature and humidity sensor with 10 m cable length each For pSYS Compact: 2 x particle sensor For pSYS Comfort and pSYS Business: 5 x particle sensor Cloud dashboard, characteristic curves, alarms, limits, reports, data storage 12 months in the cloud Temperature range 0 °C to 50 °C...
  • Page 15 Technical data Data Particle sensors Mass concentration range 0 - 1000 µg/m Particle classes and particle PM1.0 / PM2.5 / PM4.0 / PM10 sizes 0.3 µm - 1.0 µm / 2.5 µm / 4.0 µm / 10 µm Mass concentration accuracy 0 - 100 µg/m ±...