Megger CSU600A User Manual
Megger CSU600A User Manual

Megger CSU600A User Manual

Current supply units

Advertisement

Quick Links

CSU600A/AT
Current Supply Units
User's Manual
Art No. ZP-BF05E
Doc. BF0217CE
V01
2014

Advertisement

loading
Need help?

Need help?

Do you have a question about the CSU600A and is the answer not in the manual?

Questions and answers

Summary of Contents for Megger CSU600A

  • Page 1 CSU600A/AT Current Supply Units User’s Manual Art No. ZP-BF05E Doc. BF0217CE 2014...
  • Page 3 © 2013, Megger Sweden AB. All rights reserved. The contents of this manual are the property of Megger Sweden AB. No part of this work may be reproduced or transmitted in any form or by any means, except as permitted in written license agreement with Megger Sweden AB. Megger Sweden AB has made every reasonable attempt to ensure the completeness and accuracy of this document.
  • Page 4 Only connect CSU600A/AT to an outlet protected with Read the manual and comply with the fol‑ 16 A overcurrent protection. lowing instructions before using Unplug CSU600A/AT from the mains supply when it is CSU600A/AT. left unattended or not in use. Always comply with local safety regula‑...
  • Page 5 2 CONTROL PANELS BF0217CE ZP-BF05E CSU600A/AT...
  • Page 6: Control Panels

    2 CONTROL PANELS Control panels CSU600A 1. Output terminals, 0‑600 A AC 2. Output for external ammeter, 600/6 A Important If not in use, this output must be short circuited. 3. Miniature circuit breaker for mains power 4. Red lamp which indicates that thermal cutout has been triggered 5.
  • Page 7 8. Protective ground conductor terminal 9. Mains‑power‑on indicator lamp 10. Current control knob 11. Timer (0 ‑ 999.999 s) 12. Current indicator 13. Function switch (open or close function) 14. Timer stop input 15. Signal lamp for timer stop BF0217CE ZP-BF05E CSU600A/AT...
  • Page 8 Connect the external ammeter to the built‑in current transformer via terminal (2). Important When a load is applied to the CSU600A/AT, con- nector (2) must be short-circuited either via the jumper that accompanies the equipment or an external ammeter.
  • Page 9 If the overheat protection has tripped the timer display will go out. It will reset automati- cally when the temperature drops. Connecting a timer to CSU600A Set switch (7) to OFF (0) position. Connect the timer’s (Megger TM200 is recommended) start input to the start timer terminals (6).
  • Page 10: Specifications

    4 SPECIFICATIONS Specifications Specifications CSU600A/AT Outputs, AC, intermittent output (CAT I) 115 V mains voltage 230 V mains voltage Specifications are valid at nominal input voltage and an ambient Current Load time Minimum Load time Mini- temperature of +25°C, (77°F). Specifications are subject to change output without notice.
  • Page 11 BF0217CE ZP-BF05E CSU600A/AT...
  • Page 12 ▪ Insulation Power Factor (C&DF) Test Equipment worldwide. ▪ Insulation Resistance Test Equipment Megger is certified according to ISO 9001 and 14001. ▪ Line Testing Equipment Megger is a registered trademark. ▪ Low Resistance Ohmmeters ▪...