ERHS DC-2 User Instructions

Floor heating thermostat compatible with 10k or 100k floor sensor / room thermostat with built-in air sensor

Advertisement

Quick Links

1. Configuration Menu
The configuration menu allows you to set certain operating parameters.
Press power button
to turn thermostat off, hold menu button
5 seconds to enter the configuration menu. The display will show the first
item in the configuration menu.
Press
button to shift to the next item.
Use
or
to change the parameter. Press power button
configuration menu. Press power button again to turn thermostat on.
The thermostat will exit the configuration menu if no action is taken
within 8 seconds,.
Restore factory default setting: In the configuration menu, push menu
button
for 5 seconds. Display will show "DEF" blinking 3 times and
returns to Menu parameter 1.
BEFORE USING YOUR THERMOSTAT FOR THE FIRST TIME, check that the
correct sensor has been selected . For ceiling heating application, always select
Internal air sensor . (see Item 6)
This configuration menu chart summarizes the parameters available:
Press
Displayed
Item
▲or▼to
(factory default)
change
1
-6.0 --- +6.0
20℃—70℃
2
℃—
(WiFi stat)
3
5℃—20℃
20℃—70℃
4
℃— ℃
(WiFi stat)
for
to exit
Parameter Descriptions
Select temperature display adjustment
higher or lower – this recalibrates the
thermostat
Select maximum room temperature
Select minimum room temperature
Select maximum floor temperature
5
℃— ℃
( ℃)
6
( )
7
( )
( )
8
9
( )
10
( )
( )
11
(
)
(with WIFI)
12
( )
-1-
Select minimum floor temperature
:Air sensor control with floor limit
: Internal air sensor engaged – room
/ /
temperature mode
:External floor sensor engaged – floor
temperature mode
1.Backlight is off
2. Press any button for 30 seconds
/ /
backlighting
3.Backlight permanently on
:7 day / 6 period programmable mode
/
:Non programmable (manual mode)
Intelligent recovery function off
/
Intelligent recovery function on
: Anti-freezing function on
/
: Anti-freezing function off
: load requirement 12-16Amp
/ /
: load requirement 8-11Amp
: load requirement 0-7Amp
Sensor is installed
:Select when 100K
/
Sensor is installed
:Select when 10K

Advertisement

loading
Need help?

Need help?

Do you have a question about the DC-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ERHS DC-2

  • Page 1 1. Configuration Menu Select minimum floor temperature ℃— ℃ ( ℃) The configuration menu allows you to set certain operating parameters. :Air sensor control with floor limit Press power button to turn thermostat off, hold menu button : Internal air sensor engaged – room 5 seconds to enter the configuration menu.
  • Page 2 1. Set current day and time KEYBOARD & DISPLAY DESCRIPTION DC-2. 1. Turn on the thermostat, Press to enter the time setting. 2. Press to scroll between Minutes, Hours, Day. 3. Press or hold either until you reach the correct setting.
  • Page 3 HOW TO INSTALL THE THERMOSTAT: 5. Program setting Your thermostat has been pre-set in the factory with the following time & temperature Read all of the information in this manual before installing this thermostat settings: Remove front face by inserting a flat screwdriver into the slot as shown and gently turning. Attach base to the back box using mounting screws.
  • Page 4 User error and deliberate or accidental damage are not covered by 12 month manufacturers' warranty.  All wiring must conform to wiring regulation BSEN 7671.  Use this thermostat only as described in this manual. Supplied by ERHS Ltd, 70 Woolmer Way, Bordon, GU35 9QF Tel: 01420476049 www.erhs.uk info@erhs.uk...