Safety and Maintenance
Safety
The FabCure 2 uses heat and UV light to post-cure the 3D prints. It contains a heating module to
heat the chamber and maintain the ambient temperature between 30°C to 60°C and help ensure
parts are strong after post-curing.
Overheating
Protection: The unit includes multiple temperature controller to keep the
chamber from overheating.
Hot
Surfaces: Surfaces of chamber may be hot during and after post-curing. Do not touch the
internal surface of the chamber when removing parts from the FabCure 2. Wear gloves when
handling prints.
Maintenance
Keep the workspace clean for operating the FabCure 2.
Visually inspect the internal surface, turntable and transparent windows of LEDs for traces
of resin, cracks, or other damage. Clean the internal surface, turntable and windows of the
LEDs if needed.
After a post-curing cycle, remove particles of cured resin and keep the FabCure 2 clean for
next use.
If the FabCure 2 is operating at 60°C, it needs to be cooled for 15 minutes after a continuous
work for 2 hours to extend the service life of the LEDs.
Troubleshooting
Plz Close Door!
Heating Unit Error!
The display indicates "Plz Close Door" when the
door is closed.
Cause: The sensor of the door is not working.
Solution: Check if the interlock magnets are blocked.
The display indicates "Heating Unit Error!" .
Cause: The heating module does not work;
The temperature sensor does not work;
Solution: Unplug the unit.
Wait until the unit cools down.
Reconnect the power cable to restart the unit.
The display goes black.
Cause: A sudden loss of power supply during the operation.
Solution: Unplug the unit.
Wait at least three minutes.
Reconnect the power cable to restart the unit.
Network connection failed
Interlock magnets
04
Need help?
Do you have a question about the Fabcure 2 and is the answer not in the manual?