Nds surgical imaging Dome E2c Specifications

Color medical imaging displays
Hide thumbs Also See for Dome E2c:

Advertisement

Quick Links

Dome E2c
LCD DISPLAY
Technology
TFT AMLCD SPVA, 3 subpixels per pixel
Screen Size (diagonal)
21.3" (541.02 mm)
Display Resolution (pixels)
1200 x 1600 Portrait, 1600 x 1200 Landscape
Pixel Pitch
270µm, 94 dpi
Viewing Angle (CR 10:1)
+/- 85˚ (170˚) horizontal and vertical
Response Time
16/16 ms typical
OPTICAL CHARACTERISTICS
Brightness
Typical: 600 cd/m
2
Default Calibrated: 500 cd/m
2
Contrast Ratio
600:1 – typical
Palette
1786 unique shades of gray
DICOM Calibration
Panel individually characterized and calibrated at factory, DICOM calibration validation performed via RightLight™ and Dome CXtra™
PANEL INTERFACE/CONNECTIVITY
Digital Video Input
DVI Revision 1.0 single data channel connector
Analog Video Input
VGA, S-Video, composite
Digital Communication & ID
DDC2B+EDID
USB interface
Built-in USB 1.1 Hub, one upstream port,
two downstream ports
VIDEO INPUT FORMATS
Landscape Orientation
1600 x 1200 (24-bit color per pixel)
Portrait Orientation
1200 x 1600 (24-bit color per pixel)
VGA to XGA/SXGA
640 x 480, 600 x 800, 1024 x 768, 1280 x 1024
displayed in both landscape and horizontal rotation
CALIBRATION
Technique
Automatic with Internal photometer
TEST STANDARDS
Calibration Type
LCD Panel Individually characterized and calibrated at the factory, DICOM calibration verification performed via RightLight™ (internal photometer) and Dome CXtra™
IMAGING/GRAPHICS CONTROLLER
Compatible Controller Support
PHYSICAL CHARACTERISTICS
Display Size (without stand)
19" x 14.75" x 4.0" (482.6mm x 374.65mm x 102mm)
H x W x D
Weight (without stand)
Less than 12 pounds (5.44 Kg)
Mounting Options
100 mm VESA mounting standard.
Desktop stand height, pivot, swivel and tilt adjustment.
POWER REQUIREMENTS
Power Input
100 to 240 VAC, Frequency of 50-60 Hz single phase,
Less than 120 watts (typical)
ENVIRONMENTAL
Operating Temperature Range
10 to 35 degrees C
CERTIFICATIONS
Medical
FDA 510(k)
Safety & Emission
CSA, EN60601-1, FCC, CE, CCC, TUV-GM, VCCI, C-Tick
SERVICE AND SUPPORT
Warranty
5-year standard warranty
Specifications may vary based on customized solution requirements. Because we continually improve our products, specifications are subject to change without notice.
March 2009
Dome
®
Color Medical Imaging Displays
Quality. Performance. Reliability.
Dome E3cHB
TFT AMLCD Dual Domain IPS, 3 subpixels per pixel
21.3" (540mm)
1536 x 2048 Portrait, 2048 x 1536 Landscape
211µm, 120 dpi
+/- 85˚ (170˚) horizontal and vertical
24 ms max
Typical: 700 cd/m
2
Default Calibrated: 500 cd/m
2
750:1 – typical
2041 unique shades of gray
Dual channel DVI (Dual Link)
NA
DDC2B+EDID
(USB) Revision 1.1 on Stand; 1-Upstream USB "B" port; 2 - Downstream
passive USB "A" ports. • Universal Serial Bus (USB) Revision 2.0 on Monitor;
1 - Upstream USB "mini-B" port
2048 x 1536 (8-bit and 24-bit color per pixel)
1536 x 2048 (8-bit and 24-bit color per pixel)
640 x 480 – 1280 x 1024 displayed in both landscape
and horizontal rotation
Automatic with Internal photometer
18.7" x 14.5" x 4.0" (475mm x 369mm x 102mm)
Less than 15 pounds (6.35Kg)
100mm VESA mounting standard.
Desktop stand height, pivot, swivel and tilt adjustment.
100 to 240 VAC, Frequency of 50-60 Hz single phase,
96 watts (typical)
10 to 35 degrees C
FDA 510(k)
CE, VCCI, CCC, CSA-US, TUV-GM, WEEE, MIC (KCC), China ROHS, FCC Class A
5-year standard warranty
Dome E4c
TFT AMLCD Dual Domain IPS, 3 subpixels per pixel
TFT AMLCD MVA, 3 subpixels per pixel
30.0" (76.2 cm)
20.1" (510.5 mm)
1600 x 2560 Portrait, 2560 x 1600 Landscape
1600 x 1200 Landscape, 1200 x 1600 Portrait
250µm, 102 dpi
255 µm
+/- 85˚ (170˚) horizontal and vertical
+/- 85˚ (170˚) horizontal and vertical
16 ms typical
16 ms typical
Typical: 380 cd/m
2
Typical: 300 cd/m
Default Calibrated: 300 cd/m
2
Default Calibrated: 200 cd/m
700:1 typical
1000:1 typical
1786 unique shades of gray
16.7 million – programmable gamma
DICOM calibration validation via external photometer
and Dome CXtra
DVI Revision 1.0 digital dual-link connector
DVI Connector
NA
VGA Connector
DDC2B+EDID
DDC2B+EDID
NA
NA
2560 x 1600 (24 bit color per pixel)
1600 x 1200 24 bit color per pixel
NA
1200 x 1600 24 bit color per pixel
640 x 480 – 1280 x 800
640 x 480 – 1024 x 768
Automatic with Internal photometer
Manual with External Photometer
DICOM Part 14, CXtra DiCAL
Refer to the board specifications line card
28" x 18.6" x 2.8" (713mm x 473mm x 72mm)
13.8" x 17.5" x 2.8" (345mm x 445mm x 72mm)
28 pounds (12.7kg) typical
Less than 23 pounds
100mm x 200mm VESA mounting standard.
100 VESA mounting standard.
Desktop stand height, pivot, swivel and tilt adjustment.
Desktop stand height, pivot, swivel and tilt adjustment.
100 to 240 VAC, Frequency of 50-60 Hz single phase,
100 to 240 VAC, 50-60 Hz Universal Auto Switching.
120 Watts Max, 105 Watts Typical
50 Watts typical, 1 Watt standby
0 to 35 degrees C
0 to 40 degrees C
FDA 510(k)
CSA, EN60601-1, FCC, CE, CCC, TUV-GM, VCCI, KCC, C-Tick
Complies with CCC, CE, Cul, FCC Class B, KCC, TÜV-GS, VCCI
5-year standard warranty
3-year standard warranty (w/48 hr. advanced exchange)
Dome GX2MP
TFT AMLCD MVA, 3 subpixels per pixel
46" (1168 mm)
1920 x 1080 Landscape
530 µm
+/- 89˚ (178˚)
8 ms typical
2
Typical: 500 cd/m
2
2
1200:1 typical
16.8 Million colors
Manual with CXtra DiCAL
DVI-D
VGA D-SUB15
DDC2B+EDID, RS232
N/A
1920 x 1080 24 bit color per pixel
1080 x 1920 24 bit color per pixel
640 x 480 – 1920 x 1080
Manual with External Photometer
DICOM Part 14, Cxtra DiCAL
43.1" x 25.1" x 5" (1095.7mm x 637.5mm x 127mm)
92 lbs (41.73 kg)
VESA MIS F, 600 x 400 mounting standard
100-120/200-240V AC,50-60 Hz, 278 Watts Max
0 to 35 degrees C
EN60905, CE, CCISPR22/85, FCC Class A, EU ROHS
3-year standard warranty
Medical Visualization Technologies
Dome GX46

Advertisement

loading

Summary of Contents for Nds surgical imaging Dome E2c

  • Page 1 Built-in USB 1.1 Hub, one upstream port, (USB) Revision 1.1 on Stand; 1-Upstream USB “B” port; 2 - Downstream two downstream ports passive USB “A” ports. • Universal Serial Bus (USB) Revision 2.0 on Monitor; 1 - Upstream USB “mini-B” port VIDEO INPUT FORMATS...
  • Page 2 Tel: +81-3-5475-1835 Mounting Options Fax: +81-3-5475-2835 POWER REQUIREMENTS Email: info@ndssi.jp Power Input © 2009, NDS Surgical Imaging. Environmental Products may not be available in all markets and are subject to the regulatory Operating Temperature Range or medical practices that govern individ- Certifications ual markets.

This manual is also suitable for:

Dome e3chbDome e4cDome gx2mpDome gx46