Download Print this page
Cooper & Hunter SPHNS-S01E Installation & Maintenance Manual
Cooper & Hunter SPHNS-S01E Installation & Maintenance Manual

Cooper & Hunter SPHNS-S01E Installation & Maintenance Manual

Hide thumbs Also See for SPHNS-S01E:

Advertisement

Quick Links

Motion Installation & Maintenance Manual
(Model: SPHNS-S01E )
IMPORTANT:
READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS CONTROLLER . KEEP THIS MANUAL FOR
FUTURE REFERENCE.
IMPORTANT NOTICE:
 No part of this manual may be reproduced without written permission.
 Signal words (DANGER, WARNING, and CAUTION) are used to identify levels of hazard seriousness. Definitions of
identifying hazard levels are provided below with their respective signal words.
  
: Immediate hazards which WILL result in severe personal injury or death.
DANGER
       
: Hazards or unsafe practices which COULD result in severe personal injury or death.
WARNING
   
: Hazards or unsafe practices which COULD result in minor personal injury or product or property
CAUTION
damage.
NOTE: Useful information for operation and/or maintenance.
1. Safety Summary
  
DANGER
 DO NOT pour water into the Motion. This product is equipped with electrical parts that may cause serious
electrical shock when in contact with water.
WARNING
 DO NOT perform installation and electrical wiring connection by yourself. Contact your distributor or dealer
and ask them for installation work and electrical wiring by service person.
CAUTION
 DO NOT install the indoor unit, outdoor unit, controller and cable at places such as;
1. Where there is oil vapor and the oil is dispersed.
2. Where hot springs are located nearby (in a sulfuric environment).
3. Where generation, flowing, staying or leaking of flammable gas is detected.
4. Where the sea is located nearby (in the salty environment).
5. An acid or alkaline environment.
 DO NOT install the indoor unit, outdoor unit, controller and cable within approximately 3 meters
from strong electromagnetic wave radiators such as medical equipment. In case that the controller
is installed in a place where there is electromagnetic wave direct-radiation, shield the controller
and cables by covering with the steel box and running the cable through the metal conduit tube.
 In case that there is electric noise at the power source for the indoor unit, provide a noise filter.
The box □ is for checking work .Check the box after checkig.
2. Installation
1.
[2.1 Selection of Installation Place]
Select a suitable place for handling and determining the installation place of the Motion with the customer's
□ 1)
acceptance. Do not install the Motion at places such as;
where children can reach.
● where the air from the air conditioner is directly discharged, keep a distance at least 1.2M from
air conditioner.
● where place close to light.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SPHNS-S01E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cooper & Hunter SPHNS-S01E

  • Page 1 Motion Installation & Maintenance Manual (Model: SPHNS-S01E ) IMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS CONTROLLER . KEEP THIS MANUAL FOR FUTURE REFERENCE. IMPORTANT NOTICE:  No part of this manual may be reproduced without written permission.  Signal words (DANGER, WARNING, and CAUTION) are used to identify levels of hazard seriousness. Definitions of identifying hazard levels are provided below with their respective signal words.
  • Page 2 □2) Select a suitable Installation form for maximum range of monitoring. ● The Motion can project a standard rectangle in the condition of the area is large enough. The connection between sensor and LED is perpendicular to the long side. Please according to actual situation to choose suitable installation form.
  • Page 3 (C)Fix the decorative ring to the holding (D)Fix the front panel to the holding bracket and bracket and make sure the special make sure the positioning feature in a straight line. positioning feature in right position like figure above. 3. Electrical Wiring ATTENTION :...
  • Page 4 4. DSW Setting Note: DSW2 The default setting of DSW1 Default Setting DSW2 is corresponding Default Setting to ceiling mounted. If wall mounted is needed, DSW2-2 should be ON. Fault Information If LED flash at stable frequency, it means that Motion has failed. Specification Dimensions Diameter 3-30/32in.(100mm)