Motion User Manual Model: SPHNS-S01E Preface Safety Instructions Overview of Function Part Name Function setting Troubleshooting Thank you for choosing C&H commercial air conditioner! Please read this manual carefully before using , and keep it properly. Should you have any questions, please contact with the dealer or our...
Safety Instructions ● ● ● ● ● License of electric execution is needed. Do entrust dealer who has excution license. Because wrong installation might cause electric shock and fire.
Page 4
Safety Instructions ● When maintaining the machine, please contact dealer or appointed service center. Improper maintainance and wrong assembling might cause electric shock, fire and other damages. ● Please contact dealer or appointed service center, when maintaining or move Motion. Improper maintainance and wrong assembling might cause electric shock, fire and other damages.
Page 5
Safety Instructions Other warning and matters Do not let water in during maintenance. Electric parts ● exposed to water might cause electric shock. ● ● Do not shut down power supply in 3min after operating with remote control. It might cause misoperation.
Overview of Function Motion based on the detected number of people including stationary(Like sleeping) to adjust the setting temperature and fan speed. The LED flashes once whenever Motion detects the change of occupancy or it changes the setting temperature. Number of Motion's action people changes Number of people...
Parts Name Sensor o es 1. The sensor is designed to detect not only human bodies but also objects that generate heat.(For instance, moving animals can also be detected.) 2. A small exposed-area of skin may decrease the sensitivity of the sensor.
Function setting Wired remote controller has [sense] function. 2.Select [Sense] function 1.Display the Menu screen n sensor s no onne e re o e on ro er on o e sense on s n 3.Set corresponding function Sense : All the Motion's function is available, including adjusting set temperature and fan speed, and taking action setting when vacant.
Page 9
Function setting Wired remote controller don't has [sense] function. Motion's function is switched on by default. se n : Sense setting : Valid Action when vacant: Standby Time for judging vacancy: 30min ● Turn the human sensor function off if: -You want to maintain the set temperature and fan speed at a set value.
Troubleshooting Problem Cause Solution There are objects in Sensor is unable to Remove the objects front of the sensor. detect human. in front of sensor. There is a small Cool down the difference between ambient the room temperature. temperature and the body temperature .
Page 11
Troubleshooting Problem Cause Solution Incorrect LED flashes at a Turn off the human installation or the stable frequency sensor function and sensor failure. contact the retailer. The [Sense] icon Connection Make sure the of remote between human connection is vaild controller is invalid sensor and remote and restart the unit.
Need help?
Do you have a question about the SPHNS-S01E and is the answer not in the manual?
Questions and answers