Operator’s Manual SLXi-DRC Single Temperature Units Revision B T T K K 5 5 6 6 4 4 0 0 2 2 - - 2 2 - - O O P P - - E E N N June 2021...
Page 2
If more information is required, consult your Thermo King Service Directory for the location and telephone number of the local dealer. T T h h e e r r m m o o K K i i n n g g ’ ’ s s w w a a r r r r a a n n t t y y s s h h a a l l l l n n o o t t a a p p p p l l y y t t o o a a n n y y e e q q u u i i p p m m e e n n t t w w h h i i c c h h h h a a s s b b e e e e n n “...
Page 3
I I n n t t r r o o d d u u c c t t i i o o n n Software License The product includes software that is licensed under a non-exclusive, non- sublicensable, terminable and limited license to use the software as installed on the product for its intended purpose.
Page 5
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Defrost ........... 23 Engine Compartment .
Page 6
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Changing the Setpoint - Named Product ....44 Changing the Setpoint - Both Numerical Setpoint and Named Product Available .
Page 7
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Pretrip Test Considerations ......73 Pretrip Test Sequence .
Page 8
T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Refrigeration System ........103 Electrical Control System .
Safety Precautions Danger, Warning, Caution, and Notice Thermo King® recommends that all service be performed by a Thermo King dealer and to be aware of several general safety practices. Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this unit depend upon the strict observance of these precautions.
S S h h a a r r p p E E d d g g e e s s ! ! Exposed coil fins can cause lacerations. Service work on the evaporator or condenser coils should only be accomplished by a certified Thermo King technician.
E E q q u u i i p p m m e e n n t t D D a a m m a a g g e e ! ! Do not connect other manufacturer’s equipment or accessories to the unit or to the TK Batteries unless approved by Thermo King. Failure to do so can result in severe damage to equipment and void the warranty.
S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s D D A A N N G G E E R R H H a a z z a a r r d d o o u u s s G G a a s s e e s s - - P P e e r r s s o o n n a a l l P P r r o o t t e e c c t t i i v v e e E E q q u u i i p p m m e e n n t t ( ( P P P P E E ) ) R R e e q q u u i i r r e e d d ! ! Refrigerant in the presence of an open flame, spark, or electrical short...
S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s W W A A R R N N I I N N G G P P e e r r s s o o n n a a l l P P r r o o t t e e c c t t i i v v e e E E q q u u i i p p m m e e n n t t ( ( P P P P E E ) ) R R e e q q u u i i r r e e d d ! ! Protect your eyes from contact with refrigerant oil.
Page 14
S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s • I I n n g g e e s s t t i i o o n n : : Do not induce vomiting. Immediately contact local poison control center or physician.
S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s A A S S P P H H Y Y X X I I A A T T I I O O N N Move victim to fresh air and use Cardio Pulmonary Resuscitation (CPR) or mouth-to-mouth resuscitation to restore breathing, if necessary.
On/Off switch Off before doing inspections or working on any part of the unit. Please note that only Qualified and Certified personnel should attempt to service your Thermo King unit. Decals located behind service door. N N o o t t e e : : Only present on units fitted with TK TracKing Telematic's installed.
SLXi-DRC: Cooling and heating on diesel engine operation. Diesel Engine SLXi-DRC units use a 4-cylinder, water cooled, direct injection diesel engine. The engine is coupled directly to the compressor on standard units. Belts transmit power to the fans (behind the condenser coil/radiator), water pump, and alternator on all models.
N N o o t t e e : : Units equipped with the EMI 3000 package do require regular inspection in accordance with Thermo King's maintenance recommendations. Thermo King Reciprocating Compressor The SLXi-DRC units are equipped with a 4-cylinder 30.0 cu. in. (492 cm3) displacement Thermo King X430 reciprocating compressor. TK 56402-2-OP-EN...
G G e e n n e e r r a a l l I I n n f f o o r r m m a a t t i i o o n n Electronic Throttling Valve The Electronic Throttling Valve (ETV) provides enhanced control of the refrigeration system as follows: •...
SLXi-DRC units are equipped with TracKing ConnectedSuite communication device that when enabled allows remote access to unit data. Downloading the Thermo King Reefer mobile app, will allow you to monitor and manage temperature and reefer settings over the road, in the yard or in-cab via Bluetooth®.
This allows an entire fleet to be configured to match the customers’ needs. Contact your Thermo King dealer for information about programming OptiSet Plus.
FreshSet is included in OptiSet Plus. FreshSet is a demand base temperature control for fresh products. FreshSet modifies and adjusts unit airflow operation to control temperature and to maximize protection of cargo, while keeping operating costs to a minimum. Contact your Thermo King dealer for information about programming FreshSet. Defrost Frost gradually builds-up on evaporator coils as a result of normal operation.
Take the unit to a Thermo King dealer if this occurs. L L o o w w O O i i l l L L e e v v e e l l S S w w i i t t c c h h : : The low oil level switch closes if the oil drops below an acceptable level.
Page 25
Fuse Size Function 2AB Power Fuel Solenoid/Starter Circuit None No Fuse - All Bosch and Thermo King Alternators Preheat Circuit (See Note) High Speed Solenoid Circuit 8FP - CAN bus CAN connector J12 CAN connector J14 8X Power (Install Fuse in Upper Position)
Page 26
Manual Pretrip Inspection (Before Starting the Unit) Pretrip inspections are an important part of a preventative maintenance program designed to minimize operating problems and breakdowns. Perform this pretrip inspection before every trip involving refrigerated cargo. N N o o t t e e : : Pretrip inspections are not intended to take the place of regular maintenance inspections.
Page 27
M M a a n n u u a a l l P P r r e e t t r r i i p p I I n n s s p p e e c c t t i i o o n n ( ( B B e e f f o o r r e e S S t t a a r r t t i i n n g g t t h h e e U U n n i i t t ) ) the coil.
Operating Instructions SMART REEFER 3 (SR-3) Controller Overview Thermo King has applied the latest advances in computer technology to develop a device that controls temperature and unit function, and displays operating information quickly and accurately. There is nothing complicated about learning to operate the SR-3 Controller, but you will find that a few minutes studying the contents of this manual will be time well spent.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Microprocessor ON/OFF switch Microprocessor On/Off Switch is located above engine inside the unit.
Their functions are listed below. On Key: Used to turn the unit on. First the display will briefly show the Thermo King Logo and then the statement “Configuring System - Please Wait”. When the power-up sequence is complete, the display shows the Standard Display of box temperature and setpoint.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Starting the Diesel Engine C C A A U U T T I I O O N N R R i i s s k k o o f f I I n n j j u u r r y y ! !
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s O O i i l l P P r r e e s s s s u u r r e e : : Check the engine oil pressure by pressing the GAUGES soft (“Using the Gauges Key,”...
Figure 31. NAMED PRODUCT/NUMERIC SETPOINT Display Selection of Operating Modes The Thermo King CYCLE-SENTRY system is designed to save refrigeration fuel costs. The savings vary with the commodity, ambient temperatures and trailer insulation. However, not all temperature controlled products can be properly transported using CYCLE-SENTRY operation.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s The display briefly shows [DEFROST], [PROGRAMMING DEFROST - PLEASE WAIT] and then [DEFROST STARTED] (Figure 38, p.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s F F u u e e l l L L e e v v e e l l S S e e n n s s o o r r : : Displays the fuel level if a fuel level sensor is installed.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s D D a a t t a a l l o o g g g g e e r r S S e e n n s s o o r r 4 4 T T e e m m p p e e r r a a t t u u r r e e : : Displays the temperature of the CargoWatch Data Logger temperature sensor 4.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Main Menu Choices Each of these Main Menu choices will be explained later in this section: F F l l a a s s h h D D r r i i v v e e : : If a properly configured USB Flash Drive is currently connected...
Page 58
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s does not appear.
Page 59
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Figure 47.
Page 60
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Repeat the process to select a different language.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Alarms Menu If an alarm condition occurs, the large Alarm Icon will appear on the Standard Display...
Page 62
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Figure 54.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s If a serious condition occurs, the unit will be shut down to prevent damage to the unit or the load.
Alarms Menu. However, it changes to a check alarm so the unit will now start after you exit the Alarms Menu. • Contact your supervisor or a Thermo King dealer for information about alarm codes that will not clear. Datalogger Menu Initiating a Start of Trip A “Start Of Trip”...
CargoWatch/TouchPrint Datalogger contact your Thermo King dealer. 1. Connect the printer to the 6-spliced wires located inside the control box. N N o o t t e e : : Contact your Thermo King dealer about printer connection location options.
Model 50 units is to display Total Run Time Hours, Engine Hours, and Electric Run Hours. The Hourmeters Menu will not appear if all hourmeters are hidden. Contact your Thermo King dealer for information about programming the Base Controller. Hourmeters are displayed using the Hourmeter Display. From the Standard Display, press the MENU Key (Figure 61, p.
Page 67
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Figure 61.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Confirmation screens will briefly appear, and the unit will display temperature units in Celsius.
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Pretrip Test Considerations When performing a Pretrip Test, the following issues should be considered: •...
Page 74
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s •...
Page 75
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Figure 75.
Page 76
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s •...
O O p p e e r r a a t t i i n n g g I I n n s s t t r r u u c c t t i i o o n n s s Adjust Brightness The brightness of the HMI Control Panel display can be adjusted to allow for changing ambient light conditions.
Log Alarms. The TemperatureWatch™ screen is not disabled if only Log Alarm(s) are active. When the unit is turned on, the display will show the Thermo King Logo and then the “Configuring System” message. If Log Alarm(s) are present, the Log Alarm notice will appear on the display for 30 seconds.
A A l l a a r r m m C C o o d d e e s s N N o o t t e e : : The Alarm Icon does not appear on startup with Log Alarms present. If only Log Alarms exist, the display shown (Figure 86, p.
A A l l a a r r m m C C o o d d e e s s Icon will appear. The unit will be temporarily shut down if a Prevent Alarm is active. The unit will remain shut down for a timed restart interval or until the fault conditions are corrected and then restart.
A A l l a a r r m m C C o o d d e e s s Figure 88. Shutdown Alarm Pretrip Alarms If an alarm occurs during a Pretrip Test, the alarm code will be displayed as Pretrip Alarm XX, where XX is the alarm code.
Page 84
Alarm Code 92 Sensor Grades Not Set - Clears when the sensor grade is changed from 5H. The operator should contact a supervisor or a Thermo King dealer about clearing alarms using the Guarded Access Menu. Refer to (Table 1, p.
Page 85
A A l l a a r r m m C C o o d d e e s s N N o o t t e e : : The following table shows all possible alarm codes for all possible applications.
Page 86
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action High Engine Coolant If unit is shut down, repair Temperature...
Page 87
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action Check Oil Pressure Switch If unit is shut down, repair immediately.
Page 88
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action Check Hot Gas Bypass Circuit If unit is shut down, repair immediately.
Page 89
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action Internal Controller Fault Code Report alarm at end of day.
Page 90
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action Unit Not Configured Correctly Report alarm at end of day.
Page 91
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action Controller Power On Hours Report alarm at end of day.
Page 92
A A l l a a r r m m C C o o d d e e s s Table 1. Table of Alarm Codes (continued) COLOR CODE OK TO CHECK AS TAKE IMMEDIATE DEFINITIONS: SPECIFIED ACTION Description Operator Action Check Display Discharge Air Manually monitor load temperature.
This chapter describes pre-loading inspections, loading procedures, post- loading procedures, post-loading inspections, and enroute inspections. Thermo King refrigeration units are designed to maintain the required product load temperature during transit. Follow these recommended loading and enroute procedures to help minimize temperature related problems.
30 minute inspections, especially if the compartment temperature appears to be moving away from the setpoint. 3. Immediately contact the nearest Thermo King Service Center or your company office. TK 56402-2-OP-EN...
Page 96
A competent refrigeration technician is required to add refrigerant or repair the system. Contact the nearest Thermo King dealer, authorized Service Center, or call the Thermo King Cold Line for referral. Consult the Table of Contents for Cold Line information.
Page 97
L L o o a a d d i i n n g g a a n n d d I I n n s s p p e e c c t t i i o o n n P P r r o o c c e e d d u u r r e e s s Table 2.
Page 98
Jump Starting If unit battery is discharged or run down, unit may be jump started using jumper cables and another battery or vehicle. Consider the following precautions and be careful when jump starting a unit. W W A A R R N N I I N N G G P P e e r r s s o o n n a a l l P P r r o o t t e e c c t t i i v v e e E E q q u u i i p p m m e e n n t t ( ( P P P P E E ) ) R R e e q q u u i i r r e e d d ! ! A battery can be dangerous.
J J u u m m p p S S t t a a r r t t i i n n g g Figure 90. Sequence for Connecting Jumper Cables Positive (+) Terminal on Unit Battery Positive (+) Terminal on Good Battery Negative (–)Terminal on Good Battery Starter Mounting Bolt on Unit Engine 6.
Page 100
J J u u m m p p S S t t a a r r t t i i n n g g 8. Connect the black negative (–) jumper cable to the negative (–) battery terminal on a good battery. Do not let the other end of the jumper cable touch anything that conducts electricity.
Page 101
J J u u m m p p S S t t a a r r t t i i n n g g Figure 91. Sequence for Disconnecting Jumper Cables Starter Mounting Bolt on Unit Engine Negative (–)Terminal on Good Battery Positive (+) Terminal on Good Battery Positive (+) Terminal on Unit Battery TK 56402-2-OP-EN...
Refer to the information located on top of the engine to determine which model engine is in your unit, or contact your Thermo King Dealer for assistance. Model TK486V25X changed to TK486V25X1 2nd quarter 2021.
12.8 Vdc Nominal Voltage Battery Thermo King EON (880 CCA) AGM battery as standard - recommended for extreme climates and for Rail Ready (RR), Domestic Refrigerated Container (DRC), and Trailer on Flat Car (TOFC) applications. Note: If the unit is not going to be used for an extended period of time, turn the Microprocesor On/Off Power Switch to the OFF position to maximize battery life.
Page 104
S S p p e e c c i i f f i i c c a a t t i i o o n n s s Backup Battery Single cell Li-Ion 3.7V Nominal, > 2Ah -40 to + 85°C Environmental Storage Temperature...
Page 105
Maintenance Inspection Schedule Inspect/Check/Service These Items Microprocessor • Run Pretrip Test (“Performing a Pretrip Test,” p. 73). Engine • • • • Check fuel supply. • • • • Check engine oil level. • • • • Inspect belts for condition and proper tension. •...
M M a a i i n n t t e e n n a a n n c c e e I I n n s s p p e e c c t t i i o o n n S S c c h h e e d d u u l l e e Inspect/Check/Service These Items •...
Page 107
M M a a i i n n t t e e n n a a n n c c e e I I n n s s p p e e c c t t i i o o n n S S c c h h e e d d u u l l e e Inspect/Check/Service These Items —...
Page 108
Serial Number Locations On Frame In Engine Compartment TK 56402-2-OP-EN...
Page 109
Thermo King Dealer anywhere in the United States by going to thermoking. com or by using the Thermo King North American Service Directory (available from any Thermo King dealer). If you are unable to reach a dealer, then call the Toll Free Emergency Cold Line Number (888) 887-2202. The answering service will assist you in reaching a dealer to get the help you need.
Warranty Please contact your nearest Thermo King dealer for terms of the Thermo King North American Trailer Unit Limited Warranty. Refer to TK 56445-9-CH. EPA and ARB Supplemental Emissions Warranty Statement Your Thermo King unit is covered by the diesel engine manufacturer’s EPA and ARB Supplemental Emissions Warranty.
Page 111
CALIFORNIA Proposition 65 Warning TK 56402-2-OP-EN...
Page 112
1938. For more information, visit www. thermoking.com or www.tranetechnologies.com. Thermo King has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.