Control Unit Device; Preparation For Work; Turning On The Device; Setting The Temperature - Electrolux ECH/T-1000 E EEC User Manual

Electric convection heater
Table of Contents

Advertisement

Available languages

Available languages

6
http://www.home-comfort.com

Control unit device

9
1
13
14
2
3
4
5
8
6
7
Figure. 2 Control unit
1. LED display
2. Operating mode with set temperature
3. Mode of operation with a timer for
shutdown
4. Anti-frost
5. Air temperature
6. Full power
7. 1/2 power
8. Parental control
9. Control buttons
10. Power on / off
11. Button for switching operating modes
12. Full / half power
13. Display unit
14. Easy Push installation unit

Preparation for work

1. Carefully remove the heater from the
cardboard box.
2. Remove the colored stickers from the front
panel before use.
3. At the first start-up, some odor may
appear, which will disappear after the
convector starts to work.
4. Fix the device in a stable position
according to the assembly and installation
instructions.
5. After installing the convector, plug it into a
power outlet. It is not recommended to use
the same electrical outlet for simultaneous
plugging in heater and other high power
electrical appliance.

Turning on the device

10
11
Plug the power cord of the appliance into an
12
electrical outlet. Press the heater button
switch the appliance to operating mode. The
display will show the actual room temperature.
Press the on / off button
of the heater in
order to put the device into working mode.
The display shows:
– full power indicator,
– temperature indicator,
– indicator of the "Comfort" mode, as well as
the actual value of the temperature in the
room.
Note:
When switched on for the first time, the
appliance uses the full power of the heating
element.
Selecting the operating mode of the device
(full / half power)
By default, the instrument operates at full
power. To select the operating mode of the
appliance (full or half power), press the button
.
The display shows the corresponding
indicator:
– half power,
– full power.

Setting the temperature

Temperature settings will be reflected on
display. Use buttons
or
to set the
temperature. Each press of these buttons will
correspond to an increase or decrease in
temperature by 1 °C, respectively.
The factory set temperature is 24 °C.
The maximum possible temperature is 35 °C,
and the minimum is 5 °C.
If the buttons
or
are held down
continuously, the temperature will continuously
increase or decrease by 1 °C every 0.5
second. If no button presses are made within
5 seconds, the device will return to normal
operating state. The display will show the
actual room temperature.

Modes setting

Press mode key, there are 6 programs which
switch the heating between Comfort mode
and Anti-frost mode at various times of the
day and night. P1-P5 is pre-set and cannot be
altered. The «UP» programs can be defined by
the user.
The table below shows the running times for
to
each of the program.
Weekly
Pre-set
Installation place
program
Monday-
P1
Bedroom, Hallways,
Friday
Kitchen, Living room,
Dining room, Bath-
room, Conservatory
Saturday-
P1
Bedroom, Hallways,
Sunday
Kitchen, Living room,
Dining room, Bath-
room, Conservatory
Monday-
P2
Office
Friday
Saturday-
P2
Office
Sunday
Monday-
P3
Commercial location
Sunday
Monday-
P4
Home, end user power
Sunday
on the machine when
need heat, if not, then
power off
Monday-
P5
14:00pm- 17:00pm
Sunday
Home, end user need
to travel out, while
just power on the
machine with 5C to
prevent frost
UP

Setting the program

To select a program to run:
1. Press the program select button, "mode"
key, The current selected program will be
displayed, factory default program is "P4";
2. Continuous press "Mode", it will display
P1-P2-P3-P4-P5-UP-P1... until it display the
required program;
3. 3 seconds later, LED window will return
to display set temperature, The program
select option will terminate and the
selected program will be saved and used
to control the panel heater
Set the User Program «UP» mode
The «UP» program allows the heater to be set
in comfort working mode at required times
and each day of the week can have different
settings. Maximum three intervals in comfort
working mode can be input. The rest of hours
will work under anti-frost mode with default
temperature setting 5°C.
1. Press "Mode" to Choose "UP" mode;
2. Press "Prog", LED window will display "d1"
and flash, it comes to program setting for
Monday; Press "Time" could choose d1.....
d7 to get the day want to make program
setting;
3. Press "Up" or "Down" key, it will display "1."
Eco-
OFF
ON
OFF
ON
OFF
nomic
temp.
(OFF)
5
o
C
00:00am-
6:30am-
8:30am-
17:00pm-
22:30pm-
6:30am
8:30am
17:00pm
22:30pm
24:00pm
5
C
00:00am-
7:30am-
10:00am-
12:00pm-
14:00pm-
o
7:30am
10:00am
12:00am
14:00pm
17:00pm
5
C
00:00am-
6:00am-
17:00pm-
o
6:00am
17:00pm
24:00pm
5
C
00:00am-
o
24:00pm
5
C
00:00am-
6:00am-
22:00pm-
o
6:00am
22:00pm
24:00pm
5
C
0:00am-
o
24:00pm
5
C
0:00am-
o
24:00pm
User program, runs at the time defined by the use
and light will flash. It means could input the
1st time interval for comfortable mode;
4. Press "Up" or "Down", it will display "0" for
first time, continue press "Up" or "Down",
it will display 1-2-3...22-23 until get the
required starting hour, press "Time" to
confirm the start hour.
5. Press "Up" or "Down" until get the required
finished hour, press "Time" to confirm the
finished hour.
The user finishes the 1st interval setting and
switch to 2nd interval setting.
6. After confirm the 1st setting interval, it
come to 2nd interval setting.
7. Repeat step 3 to 5 to set the 2nd and 3rd
time interval for high heat output.
8. It could only be set in hour, not in minute.
9. Maximum 3 time intervals could be set in
one day. If only need to set 1 or 2 intervals,
just need to press "Time" button to save
the setting, it will come to next day.
10. Repeat above steps could set working
program for one week.
11. During above setting, just press "Prog" or
no any operation within 2 minutes, it will
quit setting and save the programs which
had set.
Check the "UP" program setting
1. Press "Prog" for 3 seconds, LED window
7
ENGLISH
ON
OFF
17:00pm-
22:30pm-
22:30pm
24:00pm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ech/t-1500 e eecEch/t-2000 e eec

Table of Contents