Residential Installation; Start-Up; Start-Up Instructions - Honeywell KaltecSoft Evolution KS20S Installation Instructions Manual

Hide thumbs Also See for KaltecSoft Evolution KS20S:
Table of Contents

Advertisement

Available languages

Available languages

6.3. Residential installation

Img. 2 Residential installation (Example)
The black lines represent the direction of water flow.

7. Start-up

Caution! The start-up must be performed by a profes-
sional installer only.

7.1. Start-up instructions

1. Manually add water in brine tank above the aircheck
(around 10 liters)
Do not fill with salt at the moment.
2. Place the valves into the bypass position (see 7.2. Valve
positions).
3. Turn on the main water supply.
4. Open a cold water tap downstream of the KS20S
softener. Let the water run a few minutes until the KS20S
softener is free from any foreign material (usually solder)
that may have resulted from the installation.
5. Once the softener is clean, close the water tap.
6. Switch on the power.
Note! Once put under electrical power, the valve may
automatically run a cycle in order to get into the service
position. Display will alternate between installer name,
time of day, flow rate and remaining capacity.
7. Push
and hold it down for 3 seconds. The system
will advance to the "first" position
Honeywell GmbH
8. When the motor stops, push
display shows "RINSE".
9. Slowly turn the bypass valve to close the outlet and open
the system inlet.
10. Run water to the drain until it runs clear.
11. Place the KS20S softener in the bypass position (system
inlet-outlet closed – full bypass).
12. Push
until the KS20S softener is back in to
softening mode.
13. Once again, push
3 seconds.
14. When the motor stops, push
display shows "BACKWASH".
15. Slowly open the inlet bypass valve 1/2 way to feed the
softener with water. Allow water to slowly fill the tank.
16. When a solid stream of water starts coming out of the
drain line, open the inlet bypass valve all the way. Let the
water drain until its clean.
17. Slowly place the bypass valve into "Normal position" (see
7.2. Valve positions) by opening the outlet side of bypass
valve. Now the system inlet-outlet is open.
18. Push
until the display shows "REGENERANT
DRAW DN" or "REGENERANT DRAW UP".
19. Carefully check the water level in the brine tank.
If it decreases, skip to the next step or see the section
"Troubleshooting" on page 15.
8
repeatedly until the
and hold it down for
repeatedly until the
MU1H-1419GE23 R1504