CHARGEMASTER DISPENSER INSTRUCTIONS
Your new ChargeMaster Dispenser is an
exciting advancement in reloading
technology. It is not only fast and convenient,
but can store up to 30 of your favorite loads.
Once you program the unit, you can recall
the stored charge and dispense it with
precision and accuracy. The ChargeMaster
is fast and repeats with the accuracy you've
come to expect from RCBS.
Getting Started:
The ChargeMaster Dispenser is used in
conjunction with the ChargeMaster 1500
Scale. The ChargeMaster scale simply plugs
into the dispenser. The transformer on the
ChargeMaster scale supplies the power for
the ChargeMaster Dispenser. If you
purchase your ChargeMaster as a Combo
Unit, the Scale & Dispenser are
preassembled into a single unit. The two
units are solidly mounted into one unit using
two rigid steel brackets on the underside of
the Dispenser and Scale. If you purchased
your ChargeMaster Scale and ChargeMaster
Dispenser separately, you will need to
assemble the two units.
ChargeMaster 1500
Step 1. To attach the scale to the dispenser,
remove the 4 screws on the bottom of
the scale and slide the scale along the
rails until the two units are plugged in
together. Replace the screws and hand
tighten. DO NOT OVER TIGHTEN.
Step 2. The ChargeMaster dispenser comes
equipped with a wind guard. This allows
you to load in conditions that most scales
will not handle.
Step 3. The knob on the side of the dispenser is
the drain. To open the drain turn knob ½
turn, twist it to remove the powder left in
the dispenser. It is not a good idea to
allow the powder to remain in the hopper
for long periods of time.
DISPENSER - KEYPAD
FUNCTION DESCRIPTION
2
3
EDIT
1
ABC
DEF
MEM
4
5
6
NEW
GHI
JKL
MNO
MEM
7
8
9
RECALL
PQRS
TUV
WXYZ
CANCEL
.
0
MEM
STOP
BACK SPACE: Deletes the last digit
displayed on the far right side of the LCD
Display window. Each time you push this
key it deletes one more digit.
TRICKLE ò: Manual operation to dispense
the powder or scroll through load data
in memory
DISP: Press key to dispense the powder
once you have entered a given charge
ENTER: Confirm your charge
EDIT MEM: Edit the LOAD DATA MEMORY
data
NEW MEM ñ: Sets the new memory data or
scrolls through load data in memory.
RECALL: Recalls the LOAD DATA MEMORY
data
MEM: This recalls the LOAD DATA MEMORY
data by memory number, 01 through 30.
Press until you get to the charge you
want to dispense or enter.
CANCEL/STOP: Clears the data or stop the
operation
SCALE - DISPLAY PANEL DESCRIPTION
Stable Over
Under
Mem
Disp Link
-5-
SME300000080
Stable: The black arrow indicates the weight is
stable
Over: The black arrow indicates the powder
weight in the pan is higher than the set value
Under: The black arrow indicates the powder
weight in the pan is lower than the set value
Mem: The black arrow indicates the desired
weight as set in the LOAD DATA MEMORY
Disp: The black arrow indicates powder is
being dispensed from the Dispenser to the
Scale
Link: The black arrow indicates that the
dispenser and scale communication link is
established
LOAD DATA MEMORY CONFIGURATION:
Each memory has four items of data:
C=_ (Cartridge), this is the name or number of
the cartridge
B_ (Bullet weight), this is the weight of the
BACK
bullet used.
SPACE
P=_ (Powder type), this is for the name or
TRICKLE
number of the powder
W_ (Weight of powder), the charge is entered
DISP
here
CONFIGURE NEW LOAD DATA MEMORY
ENTER
(30 memory stores available)
To exit dispenser and revert back to scale
mode press ZERO Key on your scale.
Step 1. Press the NEW MEM key to start the
process
Step 2. The first time you program MEM=0 will
show on the display. (MEM=01, 02, 03 and
so on through MEM=30 will appear on the
screen as each MEM field is used).
Step 3. Press the ENTER key, the display will flash
"CART" and then show C=. Key in the
cartridge one number/letter at a time. To
select a letter continue to push the
appropriate key until the desired letter
appears. After you select the appropriate
number/letter, you will need to wait until the
keys stop flashing to proceed to the next
number/letter. There are 5 spaces
available to enter the cartridge name.
When you've selected the cartridge name
press ENTER.
Step 4. The display will flash "B_WT" and shows
"B_". Key in your bullet weight and press
ENTER.
Step 5. The display will flash "POWD" and shows
P=. Key in the powder name. Remember
that you'll need to scroll through the keys
until you get to the letter you want. Allow
ChargeMaster 1500
the letter/number to stop blinking before
you proceed to the next letter/number. You
have 5 spaces to enter your powder name.
When you have your powder name on the
display, press ENTER.
Step 6. "WT" will flash and then the display will
show "W_". Key in the powder charge and
press ENTER.
Step 7. The configuration of this memory is now
complete.
Step 8. After you have finished the current memory,
the display will be ready for the next
memory number to be stored. You may
repeat the above steps until you have
entered all your information up to 30
selections.
Note 1: Press the CANCEL key to delete the
data in a field. Press the BACK
SPACE key to clear the previous digit.
Note 2: Press the ZERO key on your scale at
any time to exit the data edit process.
RECALL THE LOAD DATA MEMORY:
Step 1. Press the RECALL key, the display will
show "C=_
"
Step 2. Press the RECALL key again, the
display shows the first memory setting.
Step 3. Use the NEW MEMñ or TRICKLEò
keys to scroll through the stored
memory. When the display shows the
memory that your are looking for,
press the ENTER key.
Step 4. After you have selected it, press the
DISP key, and the powder feed tube
will start to dispense the powder.