Sofraser 9100 Technical Manual

Viscosity and temperature transmitter

Advertisement

Quick Links

9100
Technical Manual
Viscosity and temperature
transmitter
Original version
REF.: 423-0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sofraser 9100

  • Page 1 9100 Technical Manual Viscosity and temperature transmitter Original version REF.: 423-0...
  • Page 3 Technical Manual 9100 IMPORTANT THE OFFSET ADJUSTMENT IN THE AIR MUST BE THE FIRST TASK COMPLETED. Offset adjustment procedure is detailed in § 3.3. CLEAN AND DRY THE SENSOR ROD. 2. BE SURE THE PROCESS IS EMPTY. THE ROD MUST BE VIBRATING IN THE AIR.
  • Page 4: Table Of Contents

    Bottom connector – sensor’s coils ..................9 2.3.4 Bottom connector – Pt100 temperature probe & earth ......... 9 Backlight setting ..............................10 THE 9100 OPERATING FUNCTIONS ....................11 Start and menus ............................... 11 Raw data ..................................12 Offset ....................................12 Viscosity and temperature units ........................
  • Page 5: Transmitter Principle

    Technical Manual 9100 1. Transmitter principle The measuring chain is composed of three inseparable elements: the sensor, its cable and the 9100 transducer that controls it. The sensor cannot be used with another transducer or another cable type or length because they are all a part of the resonant loop so they are matched together as one vibrating system.
  • Page 6: Transmitter Technical Characteristics

    Technical Manual 9100 2. Transmitter technical characteristics Electronic device size The electronic box has the purpose to be fixed on a DIN rail, close to the process line. Its LCD screen continuously displays the viscosity value and, when connected to a Pt100 probe, the temperature value.
  • Page 7: Main Features

    Never connect the 4/20 mA outputs to a power supply, an active PLC input or tester 2.2.2 Display The 9100 transmitter device has a 2-line alphanumeric backlighting LCD screen. The effective dimensions of this screen are 40 mm * 10 mm. One line can display 8 digits. This screen is showing the different menus with the help of the 2-button face plate.
  • Page 8: Top Connector - Current Outputs

    Technical Manual 9100 2.3.1 Top connector – current outputs If the current outputs are used, the plugging scheme of the connector is as follows: Visc 4/20 mA Temp 4/20 mA The Pins η: 4/20 and T: 4/20 are used to connect the 4/20 mA outputs for Viscosity and Temperature.
  • Page 9: Bottom Connector - Sensor's Coils

    Technical Manual 9100 2.3.3 Bottom connector – sensor’s coils The plugging scheme of the connector is as follows: Pins A, B, C and D make the connection between the electronic board and the coils wires of the MIVI sensor cable. This is how the driving signal is generated and how the receiving signal is measured.
  • Page 10: Backlight Setting

    Earth & Pt100 temperature probe Backlight setting In standard, 9100 is delivered with disabled display backlight. The backlight can be enabled thanks to a switch located on the back side of the display. Hereunder the procedure that describes how to access to the switch and how to set it.
  • Page 11: The 9100 Operating Functions

       PT 100 UNIT ENABLED V mPa.s  UNIT T DegC If both Home and OK buttons are pressed simultaneously, the 9100 display will move back to the main screen showing the viscosity and the temperature. REF: 423/0...
  • Page 12: Raw Data

    Technical Manual 9100 Raw data This menu has eight screens. It allows the user to read the raw data of the main measured signals and other information specific of the unit. RAW DATA RAW DATA RAW DATA … AMP11810 FRQ 279 C 1935 Mainly, these data are used to diagnose when something wrong happens with the sensor.
  • Page 13: Viscosity And Temperature Units

    Then redo the zero in the air procedure. If this message remains even after carrying all the precaution recommended by Sofraser, the end- user can anyway validate the Offset value by pressing OK and then OK again after a last validation screen.
  • Page 14: Check 4-20Ma

    Technical Manual 9100 Check 4-20 mA In the same checking approach, this menu lets the user check the good calibration of the 4-20 mA outputs. In this function, we ask the processor to send three different known current values to the outputs and the user has to check with the help of an ammeter the value which is delivered on the dedicated top connector (see chapter 2.3.1).
  • Page 15: Enable Or Disable Temperature

    Technical Manual 9100 It is necessary to use the Sofraser Interface Software (SIS, see chapter 5) to choose the type of correlation (Linear with ax + b formula or Table) and to change the values of correlation. When the correlation is activated, an asterisk * appears on the bottom right corner of the main screen (see chapter 2.2.2).
  • Page 16: Rs485 Frame Protocol

    R: response from the board to the console Viscosity: viscosity in the unit displayed on the 9100 screen (mPa.s or Pa.s) Pt100: value in the unit displayed on the 9100 screen (°C or °F) of the temperature read by the probe when there is one...
  • Page 17 Technical Manual 9100 Example 1: to read the viscosity of a unit which has a slave address 01 (01 in Hexadecimal), with a full- scale range of 100 mPa.s and which measures a viscosity of 67.65 mPa.s S = 01 04...
  • Page 18: Sofraser Interface Software

    Sofraser (go to menu “File\Add Sensor” or “F6”). From then on, the SIS installed on this computer will always be able to communicate with the 9100. Different levels of security have been set up in the SIS, so that different users can have different possibilities on the equipment through menu “Options\Connect As”...
  • Page 19: Troubleshooting

    The value of the current 4-20 mA output is specific notes. not consistent with the measured value Contact Sofraser or your distributor if the 4- displayed on the main screen. 20 mA output range must be modified. There is no signal on the current output.