Chinese-English Comparison Table
Mo
Tu
We
Th
F
SA
Su
English
R
Chinese
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Automatic clock calibration function
In the unlocked state, first press and hold the "Cancel/Resume" key, and press the "Clock" key to display "7d=00"
to enter the automatic clock timing function, meaning the time to be adjusted in a week; "7d=-xx" means
automatic decreasing, and 7d=xx means automatic increasing; the maximum adjustment range is 28 seconds.
Press the "Week Calibration" key to adjust the time to be adjusted a week, and press the "Clock" key to return.
After setting, the time will be automatically increased or decreased at 00:31:30 every Saturday.
VI. Operation Precautions
6.1 In order to prevent the contact from heating under strong current, please tighten the screws of the wiring
terminal when connection.
6.2 It is strictly forbidden to install and disassemble the energized product.
6.3 Please replace the battery regularly to avoid insufficient battery power, resulting in unclear display or no
display. (5# battery is used in the time switch)
6.4 The equipment that may cause major economic losses or personal safety is designed to make the technical
characteristics and performance values have sufficient allowance, and safety measures such as double circuit
protection should be adopted.
VII. Common Faults and Troubleshooting
Check whether the battery voltage is not too low or there is no power.
7.2 The time switch works abnormally after power-on
Check whether the time switch time limit setting meets the required requirements, and whether the week is set in