PRODUCT
The RM-iC series readers provide an enclosed RM-4 board and attached iCLASS read
head, available in the following styles:
OVERVIEW
The RM-iC Quick Start Installation Guide provides a synopsis of installation and
connection information for RM-iC series readers. Refer to the RM-4/RM-4E Technical
Manual for in-depth technical and installation information.
Specifications
The following specifications apply to all RM-iC series readers:
NOTE
Standards
RM-iC series readers are Underwriters Laboratories Inc. (UL), Listed to Standard UL
294, Access Control System Units, Fifth Edition. RM-iC series readers must be wired in
accordance with the National Electrical Code (ANSI/NFPA 70), local codes, and the
authorities having jurisdiction.
RM1-iC - enclosed RM-4 and attached iCLASS read head
RM2-iC - enclosed RM-4 with keypad and attached iCLASS read head
RM2L-iC - enclosed RM-4 with keypad, LCD display, and attached iCLASS read
head.
Power: 12VDC, 300 mA
Cable: Beldon 9841
Cable distance from iSTAR or apC: 4,000 ft
Temperature
Indoor: 32° F to 120° F (0° C to 49° C)
Outdoor: -31° F to 151 ° F (-35 ° C to 66° C)
Qualified on 26-bit, 35-bit, 37-bit, and 32-bit Mifare serial number formats.
UL has only evaluated the 26-bit HID card format for this unit.
RM-iC Series
Quick Start
Installation Guide
Part Number UM-068
Version D0
July 2005
1
Need help?
Do you have a question about the RM-iC Series and is the answer not in the manual?
Questions and answers