Download Print this page

Ft10 Dry Power Flue Kit Assembly & Installation With Brandon Dry & Dhw Cookers - Stanley FT10 Installation & Commissioning Instructions

Fan flue for brandon dry/dhw & donard oil & gas cookers

Advertisement

FT 10 DRY POWER FLUE KIT ASSEMBLY AND INSTALLATION WITH BRANDON
SEE EXPLODED VIEW (FIG 8) WHEN ITEM NUMBERS ARE REFERRED TO:
INSTALLATION
STEP 1.
(a) Remove the air inlet plate on
the bottom right hand corner on
the front of the cooker.
(b) Remove the blanking plate on
the bottom right hand corner on
the rear of the cooker.
(c) Fix the blanking plate to the
front of the cooker. The bottom
left hand corner on the front of
the cooker is to remain open at
all times. (See Fig. 2 & 3).
STEP 2.
(a) Fit the primary air spigot (item
4) to the back of the cooker.
(b) Make two openings through the
wall, one a 150mm (6") and
one 250mm (10") diameter,
where the cooker is to be locat-
ed. The 150mm (6") opening is
for the primary air inlet duct.
The 250mm (10") is for the
telescopic section of flue con-
nector. See (Fig.4) for fixing
centres.
DRY & DHW COOKERS
A = 803mm
B = 78mm
C = 1047mm
Fig.2
D = 130mm
STEP 3.
(a) Position cooker against wall
allowing for the minimum clear-
ance. (See cooker clearances
in instruction manual).
(b) Cut the air inlet duct (item 5) to
the required length, allowing for
the connection to the cooker,
the cooker wall clearance and
air inlet terminal. (item 6)
(c) Push on Air inlet duct (item 5)
Fig.3
over the primary air spigot (item
4) and secure using one of the
jubilee clips provided. (item 7)
STEP 4.
(a) Fit cast iron bend to the cooker.
(b) Connect the telescopic section
of flue connector to the cast iron
bend by passing it through the
wall.
(c) Compress the connector until
it is the correct length for the
installation.
Fig.4
STEP 5
(a) Remove the fan cover by
(b) With the cover hinged down as
Fig.7
(c) Connect the fan to the
Note: Seal around the joints where
the fan interfaces with the horizon-
Fig.5
tal flue section.
STEP 7.
(a) Connect the air inlet terminal
5
unscrewing the two corner
screws as shown in fig.5. This
will allow the cover to swing
down from the top as shown in
Fig. 6.
shown in Fig.6 push towards the
wall until the cover pins are at
the end of the main frame slots
and lift off.
Telescopic
pipe
adjustable flue section and fix to
the wall as per Fig.8.
(item 6) to the flexible duct
(item 5) and tighten using the
remaining jubilee clip (item 7).
Fig.6
Fig.8