Sollae Systems IDIS-200 User Manual

Sollae Systems IDIS-200 User Manual

Iot data integration server

Advertisement

Quick Links

IoT Data Integration Server
IDIS-200 User Manual
Version 1.2
Sollae Systems Co., Ltd.
https://www.ezTCP.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDIS-200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sollae Systems IDIS-200

  • Page 1 IoT Data Integration Server IDIS-200 User Manual Version 1.2 Sollae Systems Co., Ltd. https://www.ezTCP.com...
  • Page 2 IDIS-200 User Manual Ver. 1.2 This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment.
  • Page 3: Table Of Contents

    1.3 Application Diagram ............................- 6 - 1.3.1 System diagram ............................- 6 - 1.3.2 IDIS-200 Gateway Information memory area ................- 6 - 1.3.3 Communication to Gateway ........................ - 7 - 1.3.4 Communication to HMI ......................... - 8 - 1.4 Specification .................................
  • Page 4 5.2 Checking communication with HMI....................... - 38 - 5.2.1 Network Configuration ........................- 38 - 5.2.2 IDIS-200 Operation State (Active mode / Backup mode) ..........- 38 - 5.2.3 TCP connection with HMI ........................- 38 - 5.3 Checking communication with Gateway ....................- 39 - 5.3.1 Communication fail with Gateway ....................
  • Page 5 IDIS-200 User Manual Ver. 1.2 7.1 Precaution................................- 42 - 7.2 Exemption from Liability ..........................- 43 - 7.2.1 English version ............................- 43 - 7.2.2 French version ............................- 44 - Revision History ........................- 46 - - 4 -...
  • Page 6: Overview

    SCADA is a system where HMI operates with IoT sensor, RTU and PLC to monitor and to provide control of remote equipment. IDIS-200 collects data from multiple remote devices to one place, and deliver HMI control commands to provide an optimized solution for IoT environment.
  • Page 7: Application Diagram

    1.3.1 System diagram Figure 1-1 IDIS-200 application diagram IDIS-200 operates as a server and stands by a connection from Gateway and HMI. Once it is connected, Modbus/TCP protocol is used to communicate with Gateway and HMI. Also, IDIS- 200 supports simultaneous connections from up to 100 Gateways.
  • Page 8: Communication To Gateway

    IDIS-200 User Manual Ver. 1.2 1.3.3 Communication to Gateway IDIS-200 supports up to 100 Gateways. Each gateway has its own ID. Default ID is numbered from SOLLAE001 to SOLLAE100. After connecting to Gateway, verify ID and write data in Gateway data memory area. While it writes data, system information is also updated in System information memory area.
  • Page 9: Communication To Hmi

    IDIS-200 User Manual Ver. 1.2 1.3.4 Communication to HMI Maximum 32 HMI can be connected to IDIS-200. It also uses Modbus/TCP protocol. After setting memory to the desired data, HMI sends queries to IDIS-200 and IDIS-200 sends data from the memory area.
  • Page 10: Specification

    IDIS-200 User Manual Ver. 1.2 1.4 Specification 1.4.1 Hardware Input Voltage AC100V ~ AC240V X 2 Power Power About 4W Consumption Dimension 437mm X 240mm X 45mm Size 19 inch rack / 1U Weight About 2.6Kg 1 × RS232 – System Console...
  • Page 11: Dimensions

    IDIS-200 User Manual Ver. 1.2 1.5 Dimensions 1.5.1 Dimensions Figure 1-4 Dimensions Dimensions may vary according to a method of measurement.  - 10 - https://www.ezTCP.com...
  • Page 12: Interface

    IDIS-200 User Manual Ver. 1.2 1.6 Interface 1.6.1 Layout There are LAN port, console port, power input port, and etc., in the back panel. The front panel has five LEDs which indicates system status. Figure 1-5 Panel layout ① STATUS LED: PWR, LINK, STS, ACT, HMI ②...
  • Page 13: Network Interface

    IDIS-200 User Manual Ver. 1.2 1.6.3 Network interface IDIS-200 has an Ethernet port for network interface. It automatically detects Ethernet speed, 10Mbps or 100Mbps. In addition, it supports auto MDI/MDIX that detects the type of cable, 1:1 or cross. Figure 1-6 RJ45 connector for Ethernet interface ⚫...
  • Page 14: Console Port

    IDIS-200 User Manual Ver. 1.2 1.6.4 Console port IDIS-200 provides one RS232 port to debug product. This port is interfaced with D-sub 9 pin male connector and is configured to 115,200bps / 8 data bits / 1 stop bit / parity NONE.
  • Page 15: Configuration

    Before configuration, IDIS-200 and a PC should be connected via serial or Ethernet. It is okay if there are switching hub between a PC and IDIS-200. Please refer to “2.3.2 Using TELNET” or “2.2 Configuration via IDIS Manager” in case of connecting with LAN cable, and refer to “2.3.3 Using Console”...
  • Page 16: Configuration Via Idis Manager

    IDIS-200 User Manual Ver. 1.2 2.2 Configuration via IDIS Manager Some of important environment variables can be configured via IDIS manager for Windows OS. For the configuration, search IDIS-200 using “MAC Address Search” or “IP address Search”. Figure 2-2 IDIS Manager - 15 - https://www.ezTCP.com...
  • Page 17: Communication Settings

    Depending on your network environment, select “Obtain an IP Automatically (DHCP)” or “Use static IP address”. ⚫ IP Address of IDIS This is for the IP address of IDIS-200. It is used for Modbus/TCP server address. ⚫ Subnet Mask A subnet mask should be set on this box.
  • Page 18: Gateway Settings

    One is Active mode that IDIS-200 receives data from Gateway, the other is Backup mode that receives backup data from active IDIS-200. If recent data is not received, mode will be changed from Active to Backup and vice versa. At the first boot, configurations of Master and Slave are defined as active mode and backup mode respectively.
  • Page 19 User can enter a short description of the Gateway. ⚫ Server System Memory Address This is for System Memory address of IDIS-200. It is fixed at 10 words for each Gateway. ⚫ Server Data Memory Address This is for Data Memory address of IDIS-200. Data from the Gateway is written in this area.
  • Page 20: Configuration Via Shell Command

    IDIS-200 User Manual Ver. 1.2 2.3 Configuration via Shell command 2.3.1 Configuration command Command Parameters Description DHCP Obtain an IP address automatically LOCAL IP Local IP Address env net SUBNET MASK Subnet Mask GATEWAY IP Gateway IP Address NAME SERVER IP...
  • Page 21 IDIS-200 User Manual Ver. 1.2 (e.g.: SOLLAE001) COMMENT Comment for Gateway Starting Server Data Memory IDIS ADDR Address WORD COUNT Data Length Enable sending query ENABLE (Yes: Enable, No: Disable) Query Type WRITE ACCESS (Yes: Write, No: Read) Query BIT ACCESS...
  • Page 22: Using Telnet

    IDIS-200 User Manual Ver. 1.2 2.3.2 Using TELNET ⚫ Setting Network Area Add or change the IP address of the network adapter on your PC like the following. In the menu of [Windows Control Panel] >> [Network Connections] >> [Properties of the Network Adapter –...
  • Page 23 ⚫ How to use ① Run the command prompt (Start >> Run >> “cmd” command) ② TELNET connection: Enter “telnet [IDIS-200 IP address]” at Window command prompt Figure 2-7 Try to make TELNET session ③ Log on via TELNET: Password is required if it is already set Figure 2-8 Log on to IDIS-200 shell via TELNET ④...
  • Page 24 ⚫ Examples of Configuration ① Enter “[Command]” at Shell Figure 2-9 Enter shell command for configuration ② Enter proper value to each parameters Figure 2-10 Configuration by TELNET ③ IDIS-200 will automatically reboot after user input is over. - 23 - https://www.ezTCP.com...
  • Page 25: Using Console

    IDIS-200 User Manual Ver. 1.2 2.3.3 Using Console ⚫ Procedures Figure 2-11 Procedures for configuration via console The way of usage is the same with TELNET. - 24 - https://www.ezTCP.com...
  • Page 26: System Management

    System Management 3.1 Upgrading Firmware 3.1.1 Firmware Firmware is a type of software for IDIS-200 operation. If there are needs for adding function or fixing bugs, the firmware can be modified and released. We recommend users to use the latest firmware.
  • Page 27 IDIS-200 User Manual Ver. 1.2 ⑥ Input the password Figure 3-2 Password Default password is “sollae”  ⑦ Confirm the completed message Figure 3-3 Sending firmware file - 26 - https://www.ezTCP.com...
  • Page 28: Status Monitoring Through Telnet / Console

    IDIS-200 User Manual Ver. 1.2 3.2 Status Monitoring through Telnet / Console 3.2.1 Network status monitoring ⚫ “st net” This command displays current Ipv4 network states of all sessions. Figure 3-4 st net 3.2.2 Dump Registers ⚫ “dr gate [gateway number]”...
  • Page 29: Reboot

    IDIS-200 User Manual Ver. 1.2 ⚫ “dr free [start address] [length]” “dr free” command displays values of a specified length in the IDIS-200 memory. Figure 3-6 dr free 3.2.3 Reboot ⚫ “reboot” Figure 3-7 reboot - 28 - https://www.ezTCP.com...
  • Page 30: Status Of Idis-200

    IDIS-200 User Manual Ver. 1.2 3.2.4 Status of IDIS-200 ⚫ “st env [start number] [quantity of gateway]” Query settings of each gateway are displayed. Figure 3-8 st env ⚫ “st gate [start number] [quantity of gateway]” This command shows communication status and comments of specified gateway.
  • Page 31 IDIS-200 User Manual Ver. 1.2 ⚫ “st mbus” “st mbus” command for status of redundancy. (ACT – redundancy Active mode, BACKUP – Backup mode) Figure 3-10 st mbus - 30 - https://www.ezTCP.com...
  • Page 32: Factory Reset

    3.3 Factory Reset This function is to initialize all the environmental values to the factory default. 3.3.1 How to reset Press FUNCTION button on the back of IDIS-200 over 5 seconds to reset. 3.3.2 Sequence of LED operation ① LINK On ②...
  • Page 33: Security Functions

    IDIS-200 User Manual Ver. 1.2 Security functions 4.1 SSL 4.1.1 SSL (Secure Socket Layer) SSL is cryptographic protocol that provides secure communication on the Internet. SSL works over TCP. 4.1.2 How to set SSL When communicating with Gateway and HMI, SSL protocol can be set to use. For SSL communication, the certification is required.
  • Page 34: How To Make A Ssl Certification

    IDIS-200 User Manual Ver. 1.2 ⚫ Secure port number for HMI IDIS-200 communicates using SSL protocol with HMI, It can be set through console/telnet. Figure 4-2 SSL settings for HMI 4.1.3 How to make a SSL certification ⚫ Click the [Certificate] button in IDIS Manager.
  • Page 35 IDIS-200 User Manual Ver. 1.2 ⚫ Input the key length and information in [Self signed certificate] and click [OK] button. Figure 4-5 Input the information ⚫ Check the information of certification. Figure 4-6 Certification information (1) - 34 - https://www.ezTCP.com...
  • Page 36: Restriction

    IDIS-200 User Manual Ver. 1.2 Figure 4-7 Certification information (2) 4.1.4 Restriction New certification is required for new IP address. To make the communication available, the communication host must set the SSL. - 35 - https://www.ezTCP.com...
  • Page 37: Setting Password

    IDIS-200 User Manual Ver. 1.2 4.2 Setting password A password can be used for protecting IDIS-200 from TELNET login or changing environmental parameters by unqualified hosts. The length is 4~64 character of Alphabet or number. Default password is “sollae”. ...
  • Page 38: Troubleshoot

    ON/OFF likely to have problems. Contact our technical support team. Check if the ACT LED on the redundancy IDIS-200 is ON. IDIS-200 keeps the current operation state (active/backup) only when it receives the latest data from the Gateway or the redundancy IDIS-200.
  • Page 39: Checking Communication With Hmi

    5.2.2 IDIS-200 Operation State (Active mode / Backup mode) IDIS-200 should be in the active operation state (ACT LED is ON) to communicate with HMI. Using the shell command (st mbus) allows to inspect without LED visual check. 5.2.3 TCP connection with HMI Check if the peer IP address and the peer port number configuration is set the same as parameters of IDIS-200.
  • Page 40: Checking Communication With Gateway

    Check the network configuration between IDIS-200 and Gateway. (If it is okay,) also check network configurations of Gateway. Make sure the peer IP address and the peer port is same as IDIS-200’s one. Table 5-2 Checklist when communication is fail - 39 - https://www.ezTCP.com...
  • Page 41: When Gateway Data Is Abnormal

    Check if HMI tag configuration for reading Gateway data is proper configuration to the IDIS-200’s environment parameters. When communication with Gateway is not successful, IDIS-200 does NOT change its communication status to the fail state until the communication fail timeout is expired.
  • Page 42: Technical Support And Warranty

    6 Technical Support and Warranty Technical Support If you have any question regarding to the operation of the product, please visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: support@eztcp.com E-mail: ⚫...
  • Page 43: Precaution And Exemption From Liability

    IDIS-200 User Manual Ver. 1.2 7 Precaution and Exemption from Liability Precaution ⚫ Sollae Systems is not responsible for product failures occurring due to user’s alternation of the product. ⚫ Specifications of the product are subject to change without prior notice for performance improvement.
  • Page 44: Exemption From Liability

    (including, without limitation, damages for loss of profit, operating cost for commercial interruption, loss of information, or any other financial loss) from the use or inability to use the IDIS-200 even if Sollae Systems Co., Ltd. or its distributors have been informed of such damages.
  • Page 45: French Version

    à caractère commercial ou de toute autre perte financière) provenant de l'utilisation ou de l'incapacité à pouvoir utiliser le boîtier IDIS-200, même si Sollae Systems Co., Ltd. ou un de ses distributeurs a été informé de la possibilité de tels dommages.
  • Page 46 IDIS-200 sans que la responsabilité de Sollae Systems Co., Ltd. et de ses distributeurs ne puissent être mise en cause, ni que le boîtier IDIS-200 puisse être échangé au titre de la garantie.
  • Page 47: Revision History

    IDIS-200 User Manual Ver. 1.2 Revision History Date Version History Author 2016.03.18 ○ Initial release Amy Kim 2016.05.25 ○ Changed default password Amy Kim ○ Updated URLs of websites 2022.08.26. ○ Removed the Components section Roy Lee ○ Removed the Related materials section - 46 - https://www.ezTCP.com...

Table of Contents