SCG-5616/5632 User Manual Ver. 1.0 Overview 1.1 Introduction The SCG-5616 is an industrial console server equipped with 16 RS232 ports, while the SCG-5632 features 32 RS232 ports. Users can remotely access serial communication devices connected to the RS232 ports of these products.
SCG-5616/5632 User Manual Ver. 1.0 1.5 Interfaces Figure 1-2 Interfaces 1.5.1 Power It uses a standard AC power cord and operates with a voltage range of AC 90V to 264V. 1.5.2 Console Port: RS232 / 115,200bps The console port is for initial setup and status checks of the product and is interfaced with a 1 x 8 RJ45 connector.
SCG-5616/5632 User Manual Ver. 1.0 ⚫ Pin Assignment Name Description Wiring Transmit Data Required Ground Required Ground Required Receive Data Required Table 1-2 pin assignment 1.5.3 Function Button This button is used to implement a factory reset. 1.5.4 USB Port The console port is for initial setup and status checks of the product.
SCG-5616/5632 User Manual Ver. 1.0 1.5.6 COM Port : RS232 / 9,600bps The COM port used to connect to the console port of the user's equipment, interfaced with a 1 X 8 RJ45 connector. Figure 1-4 COM port ⚫ Pin assignment...
SCG-5616/5632 User Manual Ver. 1.0 1.5.7 Ethernet SIG-5608 provides 10/100Mbps Ethernet. The pin assignment is as follows: Figure 1-5 Ethernet ⚫ LED of the Ethernet When a network is NOT connected: Green & Orange When a network is connected: Green...
SCG-5616/5632 User Manual Ver. 1.0 Connection 2.1 Connection Methods To use this product, you need to connect it to a PC. It offers three connection methods. Connection Method Program Requirements Console Port Any Terminal Program USB Port GUI(spFinder) MS Windows...
SCG-5616/5632 User Manual Ver. 1.0 2.4 Network Connection To use the network connection method, spFinder settings (local search, network connection) must be enabled. These settings are disabled by default from the factory, so first, use the USB port connection to enable these settings.
SCG-5616/5632 User Manual Ver. 1.0 Setting by Console Commands You can configure the device using console commands via the console port connection method. 3.1 Console Commands Command Sub Command(Option) Sub Command(Option) Description IP address settings System settings [start_port[-end port]] COM Port Settings...
SCG-5616/5632 User Manual Ver. 1.0 ⚫ dns server This is the item for configuring the DNS server IP address. ⚫ auto dns This is the item to enable or disable the feature of automatically obtaining DNS server IP addresses. This item can only be used when the DHCP item is enabled.
SCG-5616/5632 User Manual Ver. 1.0 3.4 COM Port Settings: env tty 3.4.1 Usage of env tty Example Description env tty Viewing the current COM port settings env tty 1 Setting the COM port #1 env tty 1-10 Setting the COM ports from #1 to #10...
SCG-5616/5632 User Manual Ver. 1.0 ⚫ timeout minutes This is the item for configuring the connection timeout. The setting is in minutes, ranging from 0 to 1440. If a non-zero value is set, the TCP connection will automatically terminate after the specified time if there is no data communication during the session.
SCG-5616/5632 User Manual Ver. 1.0 3.7 COM Port Scan: tty scan COM port scan is a function to check if a device is connected to a COM port. It sequentially connects to all COM port sessions and sends a specific character (CR, 0x0d), then checks for a response message.
SCG-5616/5632 User Manual Ver. 1.0 Setting by GUI You can configure the device using the GUI setup program, spFinder, via USB port connection or network (LAN port) connection. 4.1 Network 4.1.1 Obtain an IP address automatically This product can automatically obtain an IP address by DHCP. A DHCP server is required to use this.
SCG-5616/5632 User Manual Ver. 1.0 4.1.2 Use a Static IP address You can set a static IP address to this product. Figure 4-2 Use a static IP address ⚫ Select the [Use static IP address]. ⚫ Set the [Local IP address], [Subnet mask], [Gateway IP address] and [DNS IP address].
SCG-5616/5632 User Manual Ver. 1.0 4.2 General Figure 4-3 General 4.2.1 Comment This is the item for storing a description of the device for identification purposes. Up to 31 bytes can be set. 4.2.2 SSH ⚫ SSH This is the item to enable or disable SSH. When SSH is enabled, you can use a remote console via an SSH client.
SCG-5616/5632 User Manual Ver. 1.0 4.2.4 TTY (COM Port) Settings TTY is the item for configuring COM ports. Double-clicking each port opens the configuration window for that specific port. Figure 4-4 TTY (COM Port) settings ⚫ Serial Communication Item Option...
Page 21
SCG-5616/5632 User Manual Ver. 1.0 ⚫ Login message This is the item for enabling (Yes) or disabling (No) the login message output feature. When enabled, the value stored in port desc will be immediately sent to the client upon establishing a TCP connection for that session. The default value is No.
SCG-5616/5632 User Manual Ver. 1.0 4.3 Security Figure 4-5 Security 4.3.1 Password Both ID and password are required to access this product. Note that changing the default password to another is highly recommended for security. The password should be longer than 8 characters.
SCG-5616/5632 User Manual Ver. 1.0 ⚫ Remote access If this item is checked, the product can be connected from the remote network. The port number for this connection is TCP 57457. For security, this item is unchecked by default. 4.3.4 Client ID This is NOT available for this product.
SCG-5616/5632 User Manual Ver. 1.0 Management 5.1 Checking Status This is a function to view the current status of the product. Information in the [Status] window is automatically updated every second. After searching and connecting the product with spFinder, press the [Status] button to display this window. When you open this window, the spFinder connects to the product and keeps the connection until you close the window or time out.
SCG-5616/5632 User Manual Ver. 1.0 ⚫ Product Information List Item Description Product name Product name Pkgware Model name, package version, Firmware version File name File name Uptime Elapsed time since it boots up (day / hour:min:sec) IPv4 Assigned IPv4 address...
SCG-5616/5632 User Manual Ver. 1.0 5.2 Changing Firmware New firmware can be released when adding functions or fixing bugs. If you are using old firmware, you can upgrade it to the latest version. Firmware can be upgraded online or manually via spFinder.
SCG-5616/5632 User Manual Ver. 1.0 5.2.2 Manual Upgrade 그림 5-1 Manual Upgrade ⚫ Download a Firmware file to your PC. ⚫ Search and connect to your product by spFinder. ⚫ Click [Advanced] > [Firmware Change] menu. ⚫ Select to [Manual upgrade] on the [Firmware Upgrade] window.
SCG-5616/5632 User Manual Ver. 1.0 5.3 Export/Import Setting Values The [Export setting values] menu saves all setting values of the product as a file except for the password. The [Import setting values] menu loads setting values from a file which is saved by the [Export setting values] menu. Note that you need to click the [Save] button to apply the setting to your product.
SCG-5616/5632 User Manual Ver. 1.0 5.4 Factory Reset Performing the Factory Reset, you can restore all the settings to the default including the password. Follow the procedure below by checking the status of STS LED. 1. Press and immediately release the function button.
Technical Support and Warranty 6.1 Technical Support If you have any question regarding operation of the product, visit Customer Support FAQ corner and the message board on Sollae Systems’ web site or send us an email at the following address: ⚫ E-mail: support@eztcp.com...
(including, without limitation, damages for loss of profit, operating cost for commercial interruption, loss of information, or any other financial loss) from the use or inability to use the SIG-5608 even if Sollae Systems Co., Ltd. or its distributors have been informed of such damages.
à leur propriétaire et Fabricant respectif. ⚫ Conditions d’utilisations et limite de responsabilité En aucun cas Sollae Systems Co., Ltd. ou un de ses distributeurs ne pourra être tenu responsable de dommages quels qu'ils soient (intégrant, mais sans limitation, dommages...
Page 33
Sollae Systems Co., Ltd. et ses distributeurs de toute responsabilité et de toute demande de dédommagement. En cas de litige, l'entière responsabilité de Sollae Systems Co., Ltd. et de ses distributeurs vis-à-vis de votre recours durant la période de garantie se limitera exclusivement selon le choix de Sollae Systems Co., Ltd.
Need help?
Do you have a question about the SCG-5616 and is the answer not in the manual?
Questions and answers