4. Connecting the WRM-4

The detector is equipped with terminal strips used for inserting and screwing the connection
cables.

4.1. Pin assignment

| -
X2|1
Check the polarity when connecting to d.c. Voltage. When connecting the detector to a.c. voltage
~ | +
X2|2
the polarity is of no importance.
RL
X2|3
E1a
X1|1
E1b
X1|9
...
E4a
X1|4
E4b
X1|12
A1a
X1|5
A1b
X1|13
...
A4a
X1|8
A4b
X1|16
Voltage supply (12-18 V a.c. voltage or 12 – 24 V d.c. Voltage)
Reverse conductor for the outputs
turnout 1, position ahead
turnout 1, position branch
...
turnout 4, position ahead
turnout 4, position branch
LED / lamp for turnout 1 / ahead
LED / lamp for turnout 1 / branch
...
LED / lamp for turnout 4 / ahead
LED / lamp for turnout 4 / branch