Power Installation
The Power Supply Circuit of the MBU provides power for the system boards and telephones, converting the AC Input
Voltage to appropriate DC voltages. Before installation, assure that the AC power cord is NOT plugged into the AC
INLET. The Power Supply Circuit is located on the left upper side of the MBU.
The GDK-20W Power can only operate 220~240V AC based on the connection of the cable(4-wired) by the CN22 from
transformer and the connection of the cable(2-wired) by the CN21 to transformer.
Input Voltage
Connect to
Fuse
230V(+10%, -15%)
CN21
T800mAH 250V
* Caution : the GDK-20W Power can not operate with 110~127V AC.