High temp (+660 f/+349 c) pressure probe, 5000 psi, 3 pc/psi, 0.218 in dia. ss diaphragm, accel. comp., 5-point cal ranges at 5kpsi, 500psi and 100psi uht-12 element (18 pages)
Page 1
Model 122A21 Rocket motor ICP® pressure sensor, 250 psi, 20 mV/psi, Helium bleed, conical end seal Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 716-684-0001 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com...
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
OPERATION MANUAL FOR 122 SERIES HELIUM BLEED PRESSURE SENSOR INTRODUCTION The series of sensors described in this guide are designed to measure dynamic pressure in intense thermal environments typified by rocket engine combustion chambers. These sensors feature acceleration-compensated piezoelectric pressure probes, mounted in a conical end seal helium bleed adaptor.
OPERATION MANUAL FOR 122 SERIES HELIUM BLEED PRESSURE SENSOR INSTALLATION OPERATION Prepare mounting port in accordance with instructions CHARGE OUTPUT on the installation drawing. For the 122 Series, it is only necessary to select the Inspect the mounting port for burrs and tool marks at proper range on the charge amplifier and proceed the conical seal surface.
OPERATION MANUAL FOR 122 SERIES HELIUM BLEED PRESSURE SENSOR OPERATION - ICP ® MODELS NOTE: The helium tube must be plugged with a pressure-tight seal before attempting to calibrate to avoid losing pressure through the helium tube. Consult Guide G-0001B for a complete description of the low-impedance concept in instrumentation.
Page 9
Clean connectors with suitable solvent and dry. Contact factory for assistance should any problems arise. ® ICP is a registered trademark of PCB Piezotronics Drawing number: 21089 Revision: A ECO: 52570...
Page 10
122 SERIES HELIUM BLEED PRESSURE SENSOR Drawing number: 21089 Revision: A ECO: 52570...
Page 11
122 SERIES HELIUM BLEED PRESSURE SENSOR Drawing number: 21089 Revision: A ECO: 52570...
Page 12
OPERATION MANUAL FOR 122 SERIES HELIUM BLEED PRESSURE SENSOR Test Report Helium Flow Test and Burst Test Sensor Model ________________________ S/N __________________________ Initial Calibration: Input (PSI) 1000 1500 2000 2500 3000 System Output (V) Burst Test to 5000 PSI - Failed Final Calibration: Input (PSI) 1000...
Page 13
All specifications are at room temperature unless otherwise specified. 3425 Walden Avenue, Depew, NY 14043 In the interest of constant product improvement, we reserve the right to change specifications without notice. ® is a registered trademark of PCB Piezotronics, Inc.