Download Print this page

Eltako PL-SAMTEMP Quick Start Manual

Temperature controller for heating and cooling

Advertisement

Quick Links

GB
31 000 010 - 2
Temperature controller for heating
and cooling
PL-SAMTEMP
Only skilled electricians may install this
electrical equipment otherwise there is
the risk of fire or electric shock!
Temperature at mounting location:
-20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity:
annual average value <75%.
valid for devices from production week
49/20 (see bottom side of housing)
! Note: Select english language!*
Powerline temperature controller with display,
white, 55x55 mm, for mounting in switch
systems. In addition a floating control
contact 3 A/250 V AC for direct connection
of heaters and coolers. Illuminated display.
Standby loss only 0.4 watt.
The scope of supply comprises a frame R1E
and an intermediate frame ZR65/55 for the
E-Design, the temperature controller upper
part and a bottom part for attachment in
55 mm flush-mounted boxes.
The complete display can be removed from
the frame for screw mounting.
In normal mode the current room temperature
is indicated in the display as well as icons
for 'present' or 'absent' and for 'heating on'
or 'cooling active'.
Control heating or cooling with Powerline
actuators PL-SAM1L or PL-SAM2L.
1. Button programming
Press buttons ▲ and ▼ to display setpoint
and actual temperatures and change the set-
point.
Press buttons
(absent) and
to set the saved setpoint.
2. LC display
In normal mode the current room temperature
is displayed according to the figure below:
Heating active
Cooling active
Setpoint for present/
absent
3. Set the setpoint
Press any button to display the setpoint and
actual value of the temperature. Press 'absent'
or 'present' in normal mode to immediately
set the saved setpoint.
Press buttons ▲ and ▼ to change the set-
point in steps of 0.5°C. When you press the
'absent' or 'present' button during this display,
the displayed setpoint is saved to this button.
If you do not press a button for 5 seconds,
the display reverts to normal mode.
Wiring diagram
Power supply (230 V AC) according to connection
diagram.
2 floating switch outputs at Terminals 3/4
(Heating) and 3/5 (Cooling).
Concealed installation as per dimensional
drawing:
L (-23O V)
N
Voltage
input
Heating
output
Cooling
output
(present)
Central disk
Temperature actual
LON interface
Start-up
In its as-delivered state the temperature
controller is unconfigured and has no appart-
ment address. The LED flickers and the LC
display indicates 'SIENNA unconfig'.
Use the PL-SW-PROF software or the buttons
on the display to enter a new appartment
address.
Follow the instructions for the existing Power-
line devices to integrate the temperature
controller in an existing installation and
transfer their appartment address to the
temperature controller.
The section below lists the various steps and
menu items required for the configuration:
1. New installation
To create a new appartment address, hold
down the two left buttons of the display
(absent and present) until the language
selection (German/English) appears.
Service PIN
LED
Select the language with the buttons ▲
and ▼ and confirm with 'Y'. In the next step
reject RESET? with 'N', the menu goes on

Advertisement

loading

Summary of Contents for Eltako PL-SAMTEMP

  • Page 1 Cooling active 31 000 010 - 2 Central disk Temperature actual Temperature controller for heating and cooling PL-SAMTEMP Setpoint for present/ absent 3. Set the setpoint Only skilled electricians may install this Press any button to display the setpoint and...
  • Page 2 In the as-delivered state the following tem- displayed temperature. Press 'Y' to confirm perature values are saved: and save or press 'N' to reject. The program Eltako GmbH - Absent: 15°C then exits the configuration menu and reverts D-70736 Fellbach to normal mode (see step 6).