  • Page 2: Table Of Contents

    Contents 1. Product Safety Notice .............1 Measurement ..........2-3 Specification ...........4-5 - List of Accessories - Operation - Circuit Diagram 2. Installation Installation Tool ..........6 Component Name Diagram ........6 Installation Procedure ........7-9 3. Maintenance Clean and Maintenance ........10 Trouble Shooting ..........11 Matières 1.
  • Page 3: Safety Notice

    Product 1.1 Safety Notice: Make sure the main power is switched off before installing, wiring or maintenance. Keep l distance between the cook-top and the range hood should be 26”~34”. CAUTION duct air outside. Do not vent exhaust air into spaces within walls or ceilingsor into attics, crawl spaces, or garages. “CAUTION”-”For general ventilating use only.Do not use to exhaust hazardousb or explosive materials and vapors.Take care when using cleaning agents or detergents.
  • Page 4: Measurement

    1.2 Measurement HOOD BODY 26”~34”ABOVE 26”~34” COOKING SURFACE connected duct. existing suitable...
  • Page 6: Specification

    1.3 Specification Model R-828 R-838 Dimension 30" 30" Material Stainless Steel Stainless Steel Voltage 120V~ /60Hz 120V~ /60Hz Control Mode Rocker Switch Rocker Switch Speed 2 Speeds 2 Speeds Motor Type AC Motor AC Motor Motor Consumption 178W 178W Diameter 6”...
  • Page 7: Operation

    Operation Circuit Diagram R-828 R-838...
  • Page 8: Installation Tool

    2.Installation 2.1 Installation Tool Safety Goggles Electric Electric Screw Driver Scissors Tin Snips Batten Tape Gradienter Hammer Philips Screwdriver Tape Measure Pencil Triangular Rule Gloves 2.2 Component Name Diagram Power supply cord Round damper Power supply cord Round damper Connecting line Rectangular damper Casing Casing...
  • Page 9: Installation Procedure

    2.3 Installation Procedure Step 1: Locate the wooden beam and mark the location with a pencil. (or use Installation paper template) Step 2: ROOF CAP Note: To reduce the risk of fire , use only metal ductwork ROUND DUCT Decide where the ductwork will run between the hood and the outside.
  • Page 10 Step 5: No.8 The outline of a keyhole slot Fasten screws to the bottom of the cabinet Step 6: 1/14” Bit Drill an acces hole for electrical power line Step 7: Connector Take the power supply cord through the access hole. Step 8: Wiring Bulb...
  • Page 11 Step 11: Screw Power connector supply Green grounding wire Wiring case cover Wire the power supply cord Step 12: Supporting plate Fix the supporting plate Step 13: Oil collector Hang up the oil collectors...
  • Page 12: Clean And Maintenance

    3.Maintanance 3.1 Clean and Maintenance 1. All electric parts, 2.Please don’t clean include motor, the surface with switch, etc. should rough material like be away from water. steel wire ball, brush or coarse cloth, etc. It will greatly scratch the surface.
  • Page 13: Trouble Shooting

    3.2 Trouble Shooting Issue Cause Solution Electricity problem Check electricity supply Switch wire or power wire disconnected Reconnect or change switch wire or On/off out of or broken power wire order Control PCB (switch) or power PCB Change control PCB(switch) or power broken On/off...