Hitachi RAK-DJ25PCAT Instruction Manual

Hitachi RAK-DJ25PCAT Instruction Manual

Indoor unit

Advertisement

Quick Links

Split Type Air Conditioner
Indoor Unit
R32
RAK-DJ25PCAT
RAK-DJ35PCAT
Instruction manual
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
This room air conditioner is only for residential usage.
Do not use for preservation of foods, animals, plants, precision machines, art, medicine or such.
MODEL
RAK-DJ25PCAT
RAK-DJ35PCAT
RC-AGU1EA0A
- 1 -
Page 1~17
<0025041C>

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi RAK-DJ25PCAT

  • Page 1 Split Type Air Conditioner Indoor Unit MODEL RAK-DJ25PCAT RAK-DJ35PCAT RC-AGU1EA0A RAK-DJ25PCAT RAK-DJ35PCAT Instruction manual Page 1~17 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely. This room air conditioner is only for residential usage.
  • Page 2: Safety Precaution

    SAFETY PRECAUTION Please read the “Safety Precaution” carefully before operating This appliance is filled with R32. the unit to ensure correct usage of the unit. Warning” and “ Caution”. The “Warning” section contains matters which, if • Pay special attention to signs of “ not observed strictly, may cause death or serious injury.
  • Page 3 PRECAUTIONS DURING OPERATION • This room air conditioner is only for residential usage. Do not use for preservation of foods, animals, plants, precision machines, art, medicine or such. • The product shall be operated under the manufacturer specification and not for any other intended use.
  • Page 4: Operation Range

    Horizontal deflector Vertical deflector (Air Outlet) ECO Sensor Remote controller Send out operation signal to the indoor unit. So as to operate the whole unit. Model Name and Dimensions MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm) RAK-DJ25PCAT, RAK-DJ35PCAT - 4 -...
  • Page 5 Names and Functions of Each Part Indoor Unit Indications Timer Lamp (Orange) Operation Lamp (Yellow) This lamp lights when This lamp lights during operation. the timer is working. Wi-Fi Lamp (Blue) Clean Function Lamp (Green) This lamp uses for FrostWash, Auto Clean, Filter Sign.
  • Page 6 Operate Air Conditioner with Smartphone Built-in airCloud Home module airCloud Home is a cloud-based solution for remotely controlling your Hitachi air conditioning system via smart phone. You can operate the air conditioner from outside the home with your smartphone and check the operating status.
  • Page 7: Initial Settings

    2. If any harmful radio interference occurs from the air conditioner to the mobile station identification radio station, immediately stop using the radio wave and contact the local Johnson Controls-Hitachi Air Conditioning (Hereinafter JCH) technical support team to consult about measures for avoidance.
  • Page 8: Security Measures

    Equipment certification This air conditioner has a built-in wireless device that has been approved for construction design based on the Radio Law, so a license for a wireless station is not required. However, the following acts are prohibited by the Radio Law. •...
  • Page 9 • The air conditioner can be operated from a place that is no t directly visible. Therefore, for example, a situation may occur where a person in the room turns ON while another person turns OFF from outside. Especially when infants, children, the elderly, the sick, or the physically handicapped are indoors, use it when a person who can manage it is nearby.
  • Page 10 Initial Setting of App Installation of App Go to Google Play or the Apple Store (depending on your smartphone) and download the “airCloud Home” Application. Please read and agree to “the Terms of Use” on the App. ※ The App is free. Communication charges will be incurred for download and operation as per the local cell ※...
  • Page 11 (4) Switch ON your air conditioner now. Once your air conditioner is switched on or by restoring the factory settings by remote control, the air conditioner would be set into pairing mode for 10 minutes. Wi-Fi LED on air conditioner’s panel (see diagram in status indicator section) will blink for 3 times repeatedly showing air conditioner is in pairing mode.
  • Page 12 Initialization of the Built-in airCloud Home Module Reset the internal settings (restore the factory settings) by remote controller. Please note that the configuration will be cleared and pairing procedure will be required to do again to use the built-in airCloud Home module. (1) Press Mode key and ON Timer key simultaneously, pointing the remote controller towards the air conditioning unit.
  • Page 13: Maintenance

    Maintenance CAUTION Ensure unit and power supply is switched off before cleaning. Avoid touching any metal parts directly and do not use wet hands. Cleaning shall be carried out by competent person and able to follow below instruction. 1. Air Filter Please clean the filter once about every two weeks.
  • Page 14 2. Cleaning of Front Panel Remove the front panel and wash with clean water. Wash it with a soft sponge. After using neutral detergent, wash thoroughly with clean water. When front panel is not removed, wipe it with a soft dry cloth.
  • Page 15: Regular Inspection

    Information Capabilities Cooling and Dehumidifying Capabilities CAUTION • If the heat present in a room exceeds the unit’s cooling capacity Do not use a stove (for example, if there are many people in the room other heating or any other high appliances are used), the preset room temperature may not be t e m p e ra t u r e devices in proximity...
  • Page 16 FrostWash Operation Is the total operation time of the air conditioner beyond default setting when the air-conditioner is operated for about 30 minutes and stopped? The FrostWash be started that must to meet with the follow conditions. indoor FrostWash auto operation. Accumulated operating hours of the air Accumulation time conditioner have exceeded about 42 hours...
  • Page 17 If the unit still fails to operate Contact your sales agent immediately if the normally after performing the following phenomena should occur above inspections, turn the The circuit breaker switches off or the fuse blows circuit breaker off and contact frequently.