5.3.3 McMiller – Leak Stop Gel – Copper (II) sulphate electrolyte MSDS http://documents.mcmiller.com/msds.html Please contact your Polatrak representative for any questions and/or issues regarding this manual. 6. Components The probe components are shown in Figure 2 along with a parts list in Table 3.
Remove the old tip with a 7/16” (or 10mm) wrench (flats are best). Replace with the provided spare. Addi- tional spare parts may be obtained from Polatrak as needed (see table 3). Ensure that the new tip is tight, but do not overtighten (max torque 50 in-lb).
8.4.9 Replace all O-rings and backup rings with the provided spares. NEVER REUSE O-RINGS. Additional spares can be ob- tained from Polatrak (see table 3). 8.4.10 Make sure the new O-rings are properly installed and seated and that the backup ring is not twisted.
Pressure housing is Replace batteries flooded Go to backup; return unit to Polatrak. If a problem persists or is not listed, please call our hotline at +1 (713) 983-7117 and ask for Polatrak technical support. www.polatrak.com 13813 FM 529 Rd, Houston, TX 77041 | US +1 (713) 983 7117 | Email: sales@stoprust.com SMB-008 CP-Gun Manual Rev.