Identification; Supplier/Manufacturer; Type Of Product; Name Of Product - Bopp & Reuther N/F Operating Manual

Strainer
Table of Contents

Advertisement

1 Identification

1.1 Supplier/Manufacturer

Bopp & Reuther Messtechnik GmbH

1.2 Type of Product

Strainer, series N and NC

1.3 Name of Product

Strainer, series N and NC

1.4 Date of Release

30/10/03
Letzte Revision August 2008

1.5 Version No.

A-EN-03551-00Rev.C

2 Area of Application

The strainer is used to prevent measuring errors and
damages caused by impurities contained in liquids.

3 System Design

Strainers are made of a cast (NC models) or a welded
(N models) housing and a filter element with a metallic
fabric liner. The liquid flows from the top down through
the filter element in which the impurities are captured
by the fine-meshed metallic fabric. The filter element
can be removed for cleaning after opening the cover.
Bopp & Reuther Messtechnik GmbH
The NC strainer has conical internal surfaces and
highly radiused edges. These design features
guarantee that the strainer and the connected
pipework are drained completely after opening the
drain plug installed at the lowest position. There is
absolutely no liquid left in the strainer after drainage.
The strainer can be aerated or deaerated via a vent
plug installed at the highest position.
The N/A and N/F models also have a drain plug at the
bottom and a vent plug on the cover. The drained off
liquid will probably contain product residue.

4. Technical Data

4.1 Operating Temperature

NC model
-10 to max. +300 °C
(up to –200°C on request)
N model
-10 to max. +100 °C
Please pay attention to the material yield point drop
for temperatures above +100°C.

4.2 Nominal Pressure:

NC model
PN 40
(Class 150 RF and 300 RF)
N model
PN 16, 40, 100
(Class 150 RF, 300 RF
and 600 RF)