Do you have a question about the N/F and is the answer not in the manual?
Questions and answers
Summary of Contents for Bopp & Reuther N/F
Page 1
Strainer Operating Manual ПО ВОПРОСАМ ПРОДАЖ И ПОДДЕРЖКИ ОБРАЩАЙТЕСЬ: Архангельск (8182)63-90-72 Калининград (4012)72-03-81 Нижний Новгород (831)429-08-12 Смоленск (4812)29-41-54 Астана +7(7172)727-132 Калуга (4842)92-23-67 Новокузнецк (3843)20-46-81 Сочи (862)225-72-31 Белгород (4722)40-23-64 Кемерово (3842)65-04-62 Новосибирск (383)227-86-73 Ставрополь (8652)20-65-13 Брянск (4832)59-03-52 Киров (8332)68-02-04 Орел (4862)44-53-42 Тверь...
NC, N/A, N/F Strainer Table of Contents 1 IDENTIFICATION ......................3 1.1 Supplier/Manufacturer............................3 1.2 Type of Product ..............................3 1.3 Name of Product ..............................3 1.4 Date of Release ..............................3 1.5 Version No................................3 2 AREA OF APPLICATION .................... 3 3 SYSTEM DESIGN ......................
The strainer can be aerated or deaerated via a vent 1.2 Type of Product plug installed at the highest position. The N/A and N/F models also have a drain plug at the Strainer, series N and NC bottom and a vent plug on the cover. The drained off liquid will probably contain product residue.
NC, N/A, N/F Strainer 4.3 Pressure Drop NC strainer Strainer pressure drops depending on the flow rate and on the liquid viscosity with unsoiled filter elements. The highest permissible differential pressure with soiling is 3 bar. N strainer Page 4 of 9...
NC, N/A, N/F Strainer 5. Constructive Design 5.1 Model/Dimensions NC strainer N strainer NC strainer Dimensions for housing with DIN and ANSI flanges in mm DN Type PN Qmax Capacity [ℓ/min] [litre] 1250 100 NCS 3330 N strainer material A and F...
NC, N/A, N/F Strainer The N/A or N/F strainers are suitable for group 1 5.4 Filter Element Mesh Size liquids - Classification generally within Category IV, with NC: Standard 0.25 mm individual acceptance acc. to Module G of the Optional 0.025/0.04/0.063/0.1/0.5/0.8/1.0/2.0 pressure equipment directive for N/A or N/F welded N: Standard 0.25 mm...
Page 8
Strainer capacity in litres Permissible operating temperature Permissible operating pressure Mesh size: Mesh size of the inserted strainer Type plate for N/A, N/F, and NC DN 80 to DN 100 strainers Bopp & Reuther Messtechnik 0036 D-67346 Speyer Page 8 of 9...
NC, N/A, N/F Strainer Type plate for NC DN 15 to DN 50 strainers Additional plate NC DN 50 strainers 1-40-70288-550/a Bopp & Reuther Messtechnik 0036 D - 67346 Speyer achieve this, open the drain plug and drain off the 10 Disposal and liquid.
Need help?
Do you have a question about the N/F and is the answer not in the manual?
Questions and answers