Download Print this page
Icom UR-FR5000 Instructions
Icom UR-FR5000 Instructions

Icom UR-FR5000 Instructions

Channel extension modules

Advertisement

Quick Links

INSTRUCTIONS
INSTRUCTIONS
CHANNEL EXTENSION MODULES
UR-FR5000
UR-FR5100
UR-FR6000
UR-FR6100
Thank you for choosing this Icom product.
READ ALL INSTRUCTIONS carefully and
completely before using this product.
Icom is not responsible for the destruction,
damage to, or performance of any Icom or
non-Icom equipment, if the malfunction is
because of:
• Force majeure, including, but not limited to,
fires, earthquakes, storms, floods, lightning,
other natural disasters, disturbances, riots,
war, or radioactive contamination.
• The use of Icom transceivers with any
equipment that is not manufactured or
approved by Icom.
Icom, Icom Inc. and the Icom logo are registered
trademarks of Icom Incorporated (Japan) in
Japan, the United States, the United Kingdom,
Germany, France, Spain, Russia, Australia, New
Zealand, and/or other countries.
All other products or brands are registered
trademarks or trademarks of their respective
holders.
1-1-32 Kamiminami, Hirano-ku,
A6657W-1EU-4
Osaka 547-0003, Japan
Printed in Japan
© 2008–2020 Icom Inc.
Jul. 2020
FCC INFORMATION
This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and,
if not installed and used in accordance with
the instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely
to cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
CAUTION: Changes or modifications to this
transceiver, not expressly approved by Icom
Inc., could void your authority to operate this
transceiver under FCC regulations.
VOICE CODING TECHNOLOGY
The AMBE+2™ voice coding Technology
embodied in this product is protected by
intellectual property rights including patent
rights, copyrights and trade secrets of Digital
Voice Systems, Inc. This voice coding
Technology is licensed solely for use within this
Communications Equipment.
The user of this Technology is explicitly
prohibited from attempting to extract, remove,
decompile, reverse engineer, or disassemble
the Object Code, or in any other way convert
the Object Code into a human-readable form.
U.S. Patent Nos.
#8,595,002, #8,359,197, #8,315,860,
#8,200,497, #7,970,606, #6,912,495 B2.
ABOUT CE AND DOC
Hereby, Icom Inc. declares that the
versions of UR-FR5100 and UR-
FR6100 which have the "CE" symbol
on the product, comply with the
essential requirements of the Radio Equipment
Directive, 2014/53/EU, and the restriction of the
use of certain hazardous substances in
electrical and electronic equipment Directive,
2011/65/EU. The full text of the EU declaration
of conformity is available at the following
internet address:
https://www.icomjapan.com/support/
DISPOSAL
The crossed-out wheeled-bin symbol
on your product, literature, or
packaging reminds you that in the
European Union, all electrical and
electronic products, batteries, and
accumulators (rechargeable
batteries) must be taken to designated collection
locations at the end of their working life. Do not
dispose of these products as unsorted municipal
waste. Dispose of them according to the laws in
your area.
SUPPLIED ACCESSORIES
1 DC power cable ..........................................1
2 Control cable ...............................................1
3 Angles .........................................................2
4 Screws (M4×8 mm) .....................................4
5 Set screws (M3×6 mm) ...............................4
6 Tapping screws (M3×8 mm) .......................2
1 mm ≈ 1/32 inch
q
w
e
r
t
y
OPENING CASE
1. Remove 7 screws from top and 2 screws
each from both sides of the repeater, then
slide off the top cover to the direction of the
arrow as illustration below.
P 0
P 1
P 2
P 3
P 4
2. Remove 3 screws from bottom and 2 screws
each from both sides of the repeater.
P 0
P 1
P 2
P 3
P 4
3. Disconnect the control cable from the channel
module (original), then remove the front
panel.
Channel module
(original)
P 0
P 1
P 2
P 3
P 4
Front panel
4. Remove 6 screws from the front panel, then
remove the shielding plate and rubber seal.
Shielding plate
Rubber seal

Advertisement

loading

Summary of Contents for Icom UR-FR5000

  • Page 1 Object Code, or in any other way convert 6 Tapping screws (M3×8 mm) .......2 the Object Code into a human-readable form. 1 mm ≈ 1/32 inch Icom, Icom Inc. and the Icom logo are registered U.S. Patent Nos. trademarks of Icom Incorporated (Japan) in Front panel...
  • Page 2 INSTALLATION ASSEMBLING THE UNIT 3. Return the front panel, top cover and screws to their original • Install the Channel Extension Module 1. Replace the rubber seal and shielding plate of the front panel, positions. 1. Attach the supplied angles to both sides of the channel then tighten the 6 screws.

This manual is also suitable for:

Ur-fr5100Ur-fr6000Ur-fr6100