Location

 Location
The pump can be installed up to 12m from the pool or spa and up to 1m above or below the water surface level.
The pump can be installed up to 12m from the pool or spa and up to 1m above or below the
The pump should be installed on a secure and level concrete (or similar) base at least 600mm x
300mm in size, in a location that cannot be flooded by storm water or accidental immersion.
water surface level.
The rear of the motor should be no closer than 150mm from a wall, fence or barrier to allow adequate air flow.
The pump should be installed on a secure and level concrete (or similar) base at least 600mm x
The pump is weatherproof. However if installed in an enclosure, the enclosure must have inlet and outlet
300mm in size, in a location that cannot be flooded by storm water or accidental immersion.
ventilation with each opening at least 200mm² as close as practically possible to the pump motor.
The rear of the motor should be no closer than 150mm from a wall, fence or barrier to allow

Water Connection

adequate air flow.
Suction and Discharge Ports are provided with Union Adaptors for quick connection to
PVC pipes and should be sealed with ABS + PVC compatible gluing agent.
The pump is weatherproof. However if installed in an enclosure, the enclosure must have inlet and
The Suction Port is to be connected to the pool's skimmer box or suction outlet from the pool. For best
outlet ventilation with each opening at least 200mm² as close as practically possible to the pump motor.
performance a straight length of 450mm long pipe should be connected prior to the Suction Port.
The Discharge Port is to be connected to the Inlet Port of the Filter Valve.
 Water Connection
When connecting the pump below the pool surface level, ensure that Shut-off Valves are fitted to the Suction & Discharge Ports.
Suction and Discharge Ports are provided with Union Adaptors for quick connection to PVC pipes and

Power Connection

should be sealed with ABS + PVC compatible gluing agent.
The pump is supplied with a 1.8m lead and 3 pin plug to be connected to a 220V- 240V/50Hz
The Suction Port is to be connected to the pool's skimmer box or suction outlet from the pool. For best
1 phase power supply, in accordance with National Wiring rules (AS/NZS 3000).
performance a straight length of 450mm long pipe should be connected prior to the Suction Port.
The pump is to be supplied through a Residual Current Device (RCD) having a rated residual current not exceeding 30mA.
Weatherproof power point if outdoors, must be installed by an electrician.
The Discharge Port is to be connected to the Inlet Port of the Filter Valve.
When connecting the pump below the pool surface level, ensure that Shut-off Valves are fitted to the
Suction & Discharge Ports.
DO NOT USE EXTENSION LEADS OR POWERBOARDS TO RUN POOL EQUIPMENT AS THEY ARE UNSAFE AROUND THE POOL ZONE.
DO NOT USE EXTENSION LEADS OR POWERBOARDS TO RUN POOL EQUIPMENT AS THEY ARE UNSAFE AROUND THE POOL ZONE.

Priming the Pump

Before starting your pump for the first time, ensure the pump is primed by checking that the hair and lint pot is full of
water and there is sufficient water supply in the suction line.
Connect the pump to the power supply and switch onto HIGH SPEED using MODE button.
Priming the Pump
If flow is not established within approx one (1) minute, switch the pump to STANDBY using the MODE button and
Before starting your pump for the first time, ensure the pump is primed by checking that the hair and
repeat the above steps to prime the pump.
lint pot is full of water and there is sufficient water supply in the suction line.

Pairing the Pump with the Remote Control

Connect the pump to the power supply and switch onto HIGH SPEED using MODE button.
Your remote control has been factory paired to your Gemini Twin pump, however the pairing procedure can be repeated.
If flow is not established within approx one (1) minute, switch the pump to STANDBY using the MODE
a) Press and Hold the MODE button on the pump for approx 5 seconds until the AUTO light begins to flash.
button and repeat the above steps to prime the pump.
b) Then Press and Hold the STOP button on the remote control until the AUTO light on the pump turns off.
Your pump and remote are now paired.
DO NOT ALLOW THE PUMP TO RUN DRY AS THIS MAY CAUSE DAMAGE TO THE IMPELLOR AND MECHANICAL SEAL,
DO NOT ALLOW THE PUMP TO RUN DRY AS THIS MAY CAUSE DAMAGE TO THE IMPELLOR AND MECHANICAL SEAL,
VOIDING WARRANTY. THE OPERATING TEMPERATURE RANGE FOR THE PUMP IS BETWEEN 5-40˚C.
VOIDING WARRANTY. THE OPERATING TEMPERATURE RANGE FOR THE PUMP IS BETWEEN 5-40˚C.
Any water ingress will not be covered by warranted.
Any water ingress will not be covered by warranted.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gemini Enduro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PoolRite Gemini Enduro

  • Page 1 Gemini Enduro Location   Location • The pump can be installed up to 12m from the pool or spa and up to 1m above or below the water surface level. • The pump can be installed up to 12m from the pool or spa and up to 1m above or below the •...
  • Page 2 EQUIPMENT AS THEY ARE UNSAFE AROUND THE POOL ZONE. your Warranty Online register your Warranty Online register your Warranty Online Poolrite is an Australian made and owned product of The Evolve Group of companies See the full range of products at register your Warranty Online Auto...

Table of Contents