Thermostat
DIP Switch 1 On Board Links Must Be Cut To Select System Options
1 Heat / 1 Cool
NOTE:
Use DIP
switch 2 to set
sceond-stage heat
ON delay.
OFF - 7 minutes
ON - 12 minutes
1 Heat / 2 Cool
NOTE:
Use DIP
switch 2 to set
sceond-stage heat
ON delay.
OFF - 7 minutes
ON - 12 minutes
1 Heat / 2 Cool
with t'stat with
dehumidification
mode
NOTE:
Use DIP
switch 2 to set
sceond-stage heat
ON delay.
OFF - 7 minutes
ON - 12 minutes
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the integrated control.
508145-01G / 31-5000660
DIP Switch Settings and On-Board Links
DO NOT CUT ANY
ON-BOARD LINKS
ON
CUT ON-BOARD LINK
ON
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
ON
CUT ON-BOARD LINK
W914
DEHUM
Table 9. Field Wiring
Issue 2220
Wiring Connections
FURNACE
OUTDOOR
T'STAT
TERM. STRIP
*
*Not required on all units
FURNACE
OUTDOOR
T'STAT
TERM. STRIP
*
*Not required on all units
FURNACE
OUTDOOR
T'STAT
TERM. STRIP
o
*Not required on all units
Page 23 of 38