Eagle Hydraulic Operation And Troubleshooting Manual

12 & 24 volt dc power units

Advertisement

Quick Links

OPERATION AND
TROUBLESHOOTING GUIDE
12 & 24 volt DC Power Units
Revision 2.0-2018

Advertisement

Table of Contents
loading

Summary of Contents for Eagle Hydraulic

  • Page 1 OPERATION AND TROUBLESHOOTING GUIDE 12 & 24 volt DC Power Units Revision 2.0-2018...
  • Page 2: Warranty

    Any disassembly or modification made on a power unit that is still under warranty will automatically VOID that warranty. Eagle Hydraulic stands behind their products. All our power units are tested and verified prior to shipping. Therefore, any signs of improper application will void the warranty.
  • Page 3: Operation And Maintenance

    ELECTRICAL WIRING Every DC power unit from Eagle Hydraulic is assembled with a solenoid starter assembly that is mounted on the motor. Independent battery leads must be connected to the terminals of the DC motor and solenoid starter. See the drawing below: Connect the positive side of the battery to the positive side of the solenoid starter (B), mounted on the electrical motor.
  • Page 4: Hydraulic Connection

    MAINTENANCE All Eagle Hydraulic power units are designed to give a long, trouble free service life with just a few maintenance checks at regular intervals.
  • Page 5 SYMPTOMS AND SOLUTIONS - EASY TROUBLESHOOTING GUIDE Please use this guide to easily troubleshoot your Eagle Hydraulic power unit. It is recommended to go through each step, as this guide has been created in a logical sequence. If followed from top to bottom, you should go through all possible symptoms and should be able to find the problem.
  • Page 6 If air is being introduced in the system, the gear pump might have some difficulty priming. Listen for distinctive cavitation sounds from pump and verify all hydraulic hoses and fittings for proper sealing. Cylinder won’t hold in place (drift down) Check valve on unit might leak •...
  • Page 7 Eagle Hydraulic technical department for advice and support. All unit returns must be authorized by Eagle Hydraulic and must be accompanied by a RGA number. In the invent that you need to send you power unit back, please make sure that there is no oil left both in the tank and in the block.
  • Page 8 12055 Arthur-Sicard, Mirabel, Québec, J7J 0E9 (450) 433-2800 T. (450) 433-3004 F. info@eagle-hydraulic.com PROUDLY ASSEMBLED AND TESTED IN CANADA...

Table of Contents