Models : ARY7UUAB / AOY7USAJL
ARY9UUAB / AOY9USAJL
4-WAY
VALVE COIL
FAN MOTOR
THERMAL
PROTECTOR
2004.06.14
GREEN / YELLOW
FAN MOTOR
F M
6
5
4
3
2
1
WHITE
2
BLACK
1
CONTROL BOARD
1
3
3
2
1
1
3
4
5
6
2 ( N )
OUTDOOR UNIT
CONTROL
6
5
4
BLACK
BLACK
FUSE 5A
BLACK
SV
FAN MOTOR
CAPACITOR
RED
ORANGE
FAN MOTOR
CAPACITOR
2
1
2
1
3
2
1
2
1
2
3
5 4
1
8
7
6
1
2
3
TERMINAL
REMOTE
CONTROL
TO REMOTE CONTROL UNIT
3
N
L
2 ( N )
1 ( L )
WHITE
BLACK
BROWN
BROWN
COMPRESSOR
CAPACITOR
WHITE
BLACK
- 4 -
2
1
2
1
2
1
3
2
1
TO POWER SOURCE
BLACK
MAIN RELAY
5
4
6
1
RED
OVERLOAD
S
PROTECTOR
C
BLACK
COMPRESSOR
R
INDOOR UNIT
OUTDOOR UNIT

Advertisement