Download Print this page

Advertisement

Quick Links

2004.06.14
SPLIT TYPE
AIR CONDITIONER
DUCT
Models
Indoor unit
ARY7FUAB
ARY7UUAB
ARY9FUAB
ARY9UUAB
C O N T E N T S
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . . . . . . 2
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . . . 5
ERROR CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . . . . . 10
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
(50Hz)
type
Outdoor unit
AOY7FSAJ
AOY7USAJL
AOY9FSAJ
AOY9USAJL

Advertisement

loading

Summary of Contents for Fujitsu ARY7FUAB

  • Page 1: Table Of Contents

    SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARY7FUAB AOY7FSAJ ARY7UUAB AOY7USAJL ARY9FUAB AOY9FSAJ ARY9UUAB AOY9USAJL C O N T E N T S SPECIFICATIONS ......1 OUTLINE AND DIMENSIONS .
  • Page 2: Specifications

    S P E C I F I C A T I O N S INDOOR UNIT ARY7FUAB ARY7UUAB ARY9FUAB ARY9UUAB OUTDOOR UNIT AOY7FSAJ AOY7USAJL AOY9FSAJ AOY9USAJL COOLING CAPACITY (kW) 2.15 2.15 2.80 2.70 HEATING CAPACITY (kW) ----- 2.45 ----- 3.10...
  • Page 3: Outline And Dimensions

    O U T L I N E A N D D I M E N S I O N S INDOOR UNIT (unit : mm) OUTDOOR UNIT - 2 - 2004.06.14...
  • Page 4: Circuit Diagram

    C I R C U I T D I A G R A M Models : ARY7FUAB / AOY7FSAJ ARY9FUAB / AOY9FSAJ GREEN / YELLOW FAN MOTOR FAN MOTOR CAPACITOR WHITE BLACK CONTROL BOARD BLACK 2 ( N ) REMOTE...
  • Page 5 Models : ARY7UUAB / AOY7USAJL ARY9UUAB / AOY9USAJL GREEN / YELLOW FAN MOTOR FAN MOTOR CAPACITOR WHITE BLACK CONTROL BOARD 2 ( N ) TERMINAL OUTDOOR UNIT REMOTE CONTROL CONTROL TO REMOTE CONTROL UNIT INDOOR UNIT OUTDOOR UNIT TO POWER SOURCE 2 ( N ) 1 ( L ) WHITE...
  • Page 6: Refrigerant System Diagram

    R E F R I G E R A N T S Y S T E M D I A G R A M Models : ARY7FUAB / AOY7FSAJ ARY9FUAB / AOY9FSAJ INDOOR UNIT OUTDOOR UNIT Capillary tube Refrigerant pipe 6.35 mm (1/4")
  • Page 7 Models : ARY9UUAB / AOY9USAJL INDOOR UNIT OUTDOOR UNIT Strainer Refrigerant pipe 6.35 mm (1/4") Capillary tube Compressor Evaporator Condenser Refrigerant pipe 9.52 mm (3/8") Muffler 4-Way valve Charging valve Cooling Heating : Flare coupling - 6 - 2004.06.14...
  • Page 8: Error Contents

    E R R O R C O N T E N T S (1) Stop the air conditioner operation. (3) Press the set temperature buttons simultaneously for (2) Press the master control button and the fun control button 5 seconds or more to stop the self-diagnosis. simultaneously for 2 seconds or more to start the test run.
  • Page 9: Indoor P. C. Board Circuit Diagram

    C I R C U I T B O A R D C I R C U I T D I A G R A M Models : ARY7FUAB CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ARY9FUAB ARY7FUAB : EZ-00307WSE-C...
  • Page 10 Models : ARY7UUAB CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ARY9UUAB ARY7UUAB : EZ-00323HSE-C ARY9UUAB : EZ-00322HSE-C R5 62K B2B-XASK-1-A <RSP2-2W> R15 - R17 CN8-1 BLACK ROOM TEMPERATURE 10K <1/10W> x 3 R44 1.0K <1/10W> CN8-2 BLACK THERMISTOR 4700P R18 1.0K <1/10W> R43 10K CUSTOM CODE SWITCHING <ECQM>...
  • Page 11: Disassembly Illustration

    D I S A S S E M B L Y I L L U S T R A T I O N Models : ARY7FUAB ARY7UUAB ARY9FUAB ARY9UUAB 184-1 196-2 588-1 588-2 381-4 - 10 - 2004.06.14...
  • Page 12 Models : ARY7FUAB ARY7UUAB ARY9FUAB ARY9UUAB 143-1 653-1 320-1 - 11 - 2004.06.14...
  • Page 13 Models : ARY7FUAB ARY7UUAB ARY9FUAB ARY9UUAB 143-1 982-2 982-1 381-4 815-1 815-2 - 12 - 2004.06.14...
  • Page 14 Models : AOY7FSAJ AOY7USAJL AOY9FSAJ AOY9USAJL - 13 - 2004.06.14...
  • Page 15 Models : AOY7FSAJ AOY9FSAJ 982-1 32-1 982-2 Models : AOY7USAJL AOY9USAJL 982-1 32-1 982-2 - 14 - 2004.06.14...
  • Page 16 Models : AOY7FSAJ AOY9FSAJ 128-1 - 15 - 2004.06.14...
  • Page 17 Model : AOY7USAJL 350-2 350-3 13-1 350-1 - 16 - 2004.06.14...
  • Page 18 Model : AOY9USAJL 128-1 13-1 - 17 - 2004.06.14...
  • Page 19: Parts List

    ARY7FUAB ARY9FUAB ARY7UUAB ARY9UUAB P A R T S L I S T When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. INDOOR UNIT Part No. Ref.
  • Page 20 AOY7FSAJ AOY9FSAJ AOY7USAJL AOY9USAJL When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. OUTDOOR UNIT Part No. Ref. Ord. Description Q'ty AOY7FSAJ AOY9FSAJ AOY7USAJL AOY9USAJL Guard (Fan) 9304109006 9304109006 9304109006...
  • Page 21 STANDARD ACCESSORIES INDOOR UNIT ACCESSORIES Name and Shape Q'ty Application Parts No. Installation For positioning the indoor 9364225005 template unit For suspending the indoor Hook 9363195002 metal unit from ceiling For installing the hanger Tapping screw 301171164104 ( 4 x 10) Special nut A For suspending the indoor 313005446653...
  • Page 22 0401J2501 January 2004 Printed in Japan 2004.06.14...