Technical Specifications • Available size: 2-3”. • Max. working pressure: 10 bar. • Max. flow rate: o 2” - 25 m o 3” - 45 m • Available in 40 – 140 mesh. • Flushing flow rate: o 2 bar – 9.0 m o 3 bar - 12 m •...
First Operation • Open the water source and inlet maintenance valve and check for leaks. • Perform 2-3 flushing cycles as outlined below. • Filter is ready for use. Flushing the filter • The disc element needs to be cleaned when the head loss across the filter reaches 0.5-0.7 bar and the red pin is pushed out from the pressure indicator (Picture E).
Page 5
ADIR Semi–Automatic 2” filter TDS – Gen2 Installation and maintenance instructions 1 action Box contents • Main filter assembled – picture A • Valve F/F 1/2" and Nipple M/M ½” – picture B • Pressure indicator kit and fittings – picture C Pressure indicator (Picture C-3).
Page 6
First Operation • Open the water source and inlet maintenance valve and check for leaks. • Perform 2-3 flushing cycles as outlined below. • Filter is ready for use. Flushing the filter • The disc element needs to be cleaned when the head loss across the filter reaches 0.5-0.7 bar and the red pin is pushed out from the pressure indicator (Picture E).
Page 7
Periodic Maintenance 1 Action filters Warning: • Never open the filter under pressure! to release pressure turn the handle to flush position and open the flush valve 1/2" • Before servicing the filter make sure it is empty of water and the inlet valve is closed.
Page 8
ADIR Semi–Automatic 3” filter TDS – Gen2 Installation and maintenance instructions 2 action Box contents • Main filter assembled – picture A • Valve 2" FF – picture L • Valve F/F 1/2" and Nipple M/M ½” – picture B •...
Page 9
First Operation • Open the water source and inlet maintenance valve and check leaks. • Perform 2-3 flushing cycles as outlined below. • Filter is ready for use. Flushing the filter • The disc element needs to be cleaned when the head loss across the filter reaches 0.5-0.7 bar and the red pin is pushed out from the pressure Picture M...
Page 10
ADIR Semi–Automatic 2” filter TDS –Gen2 Installation and maintenance instructions 2 action Box contents • Main filter assembled – picture A • Valve 2" FF – picture L • Valve F/F 1/2" and Nipple M/M ½” – picture B •...
Page 11
First Operation • Open the water source and inlet maintenance valve and check leaks. • Perform 2-3 flushing cycles as outlined below. • Filter is ready for use. Flushing the filter • The disc element needs to be cleaned when the head loss across the filter reaches 0.5-0.7 bar and the red pin is pushed out from the pressure Picture M...
Page 12
Periodic Maintenance 2 Action Filters Warning: • Never open the filter under pressure! to release pressure turn the handle to flush position and open the flush valve 1/2" • Before servicing the filter make sure it is empty of water and the inlet valve is closed.
Page 13
Trouble shooting for all models • Head loss is not decreasing after flushing cycle: Check that the pressure is not below 2 bar. Check that there is no disturbance to the flushing flow. Flush the internal screen by opening its valve 1/2". Repeat the flushing cycle again, do not forget to open the filter valve 2"...
Page 14
TDS - Proper flushing of discs It is recommended to clean the discs before and after irrigation season to ensure proper functioning of the filter for many years. Manual flushing is required when the filter is clogged and flushing process does not clean it properly.
Page 15
Step 1 Step 2 Release the filter clamp Remove the filter cup and then remove the O-ring carefully Step 3 Step 4 Remove the dics Place the discs in HCL solution Ver_2-08-22...
Page 16
Step 5 Reassemble the filter After installing the discs back in the filter perform several flushing cycles. Ver_2-08-22...