10. Removal Procedure
10.1 Removal Procedure of Indoor Unit
NOTE: Take A5 panel for an example.
Step
1. �����������
���������������������
�����������������������
the groove on the front panel.
��������������������
respectively.
2. Remove horizontal louver
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
3. Remove panel
a
(1)A1 display: Screw off the 2 screws that
are locking the display board. Separate
the display board from the front panel.
(2)A3/A5 display: Screw off the 2 screws
that are locking the display board.
Separate the panel rotation shaft from
b
the groove ��� the front panel and then
removes the front panel.
61
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Procedure
Front panel
�����
Horizontal louver
A1 display
A3/A6 display
Screws
Front panel
������
Groove
Location of step motor
Axile bush
Screws
Panel rotation
Groove
Installation and Maintenance
Service Manual
Front
case
Panel
A5 display
Screws